1、Designation: D1544 04 (Reapproved 2010)Standard Test Method forColor of Transparent Liquids (Gardner Color Scale)1This standard is issued under the fixed designation D1544; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o

2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the measure

3、ment of the color oftransparent liquids by means of comparison with arbitrarilynumbered glass standards.1.2 Users of this method should have normal color vision.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standa

4、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 AST

5、M Standards:2D1545 Test Method for Viscosity of Transparent Liquids byBubble Time MethodD6166 Test Method for Color of Naval Stores and RelatedProducts (Instrumental Determination of Gardner Color)E308 Practice for Computing the Colors of Objects byUsing the CIE System3. Significance and Use3.1 This

6、 test method applies to drying oils, varnishes, fattyacids, polymerized fatty acids, and resin solutions. Its applica-tion to other materials has not been tested.4. Apparatus4.1 Glass Standards, 18, numbered separately, and havingthe color characteristics given in Table 1. The color shall beproduced

7、 by the glass components only. Some glass standardsin use today do not conform to the values reported in Table 1.The calibration of glass standards should be verified prior touse; a suitable procedure for their calibration is contained inAppendix X1.4.2 Glass Tubes, clear, 10.65 mm in inside diamete

8、r andabout 114 mm in outside length. (Viscosity tubes, as describedin Test Method D1545, are satisfactory.)4.3 Suitable apparatus for comparing sample and standard.The apparatus may be of any design, but should have thefollowing characteristics:4.3.1 IlluminationCIE Illuminant C.4.3.2 Surrounding Fi

9、eldThe field should be black.4.3.3 Field of ViewThe specimen and one or more stan-dards should subtend a visual angle of about 2 and be in thefield of view simultaneously.1This test method is under the jurisdiction of Committee D01 on Paint andRelated Coatings, Materials, and Applications and is the

10、 direct responsibility ofSubcommittee D01.26 on Optical Properties.Current edition approved June 1, 2010. Published June 2010. Originallyapproved in 1958. Last previous edition approved in 2004 as D1544 04. DOI:10.1520/D1544-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org,

11、 orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 Color Specifications of Reference StandardsGardnerColorStandardNumberChromaticity CoordinatesALuminousTransmittanceY,%Tran

12、smittanceTolerance,6xy1 0.3177 0.3303 80 72 0.3233 0.3352 79 73 0.3329 0.3452 76 64 0.3437 0.3644 75 55 0.3558 0.3840 74 46 0.3767 0.4061 71 47 0.4044 0.4352 67 48 0.4207 0.4498 64 49 0.4343 0.4640 61 410 0.4503 0.4760 57 411 0.4842 0.4818 45 412 0.5077 0.4638 36 513 0.5392 0.4458 30 614 0.5646 0.42

13、70 22 615 0.5857 0.4089 16 216 0.6047 0.3921 11 117 0.6290 0.3701 6 118 0.6477 0.3521 4 1AA duplicate standard shall have chromaticity coordinates that differ from thereference standard by no more than one third of the difference in x or y betweenadjacent reference standards. In any one set, no two

14、standards shall be closertogether than two thirds of the difference in x or y between correspondingreference standards.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3.4 Separation of Standard and SpecimenThere shouldbe a percepti

15、ble separation between specimen and standard, butthis should be as small as is mechanically possible.5. Procedure5.1 Fill a glass tube with the material under test. If thematerial is perceptibly cloudy, first filter it.5.2 Compare with glass standards, determining which stan-dard most closely matche

16、s the specimen in brightness andsaturation. Ignore hue differences.6. Report6.1 Report the color as the number of the standard mostclosely matching the specimen. If more precise measurementsare needed, report as either matching a standard or lighter ordarker. Thus, between colors 5 and 6, the steps

17、will be 5, 5+,6, and 6.6.2 Report any significant difference in hue between thesample and the nearest-match standard.7. Precision and Bias7.1 On the basis of a study in which one observer at each of80 laboratories made duplicate determinations on four samples,the “between” and “within” standard devi

18、ations were found tobe 0.5 and 0.1 color number, respectively. Based on thesestandard deviations, the following criteria should be used forjudging the acceptability of results at the 95 % confidencelevel.7.2 RepeatabilityTwo results obtained by a single opera-tor should be considered suspect if they

19、 differ by more than twothirds of a color number.7.3 ReproducibilityTwo results, each of the mean ofduplicate measurements, made by operators in different labo-ratories should be considered suspect if they differ by morethan four thirds of a color number.NOTE 1If desired, liquid standards matching t

20、he colors given in Table1, in glass tubes similar to the sample tubes may be used. These may befilled with potassium chloroplatinate for the light colors and solutions offerric chloride and cobalt chloride in hydrochloric acid for the darkercolors. The specifications and approximate composition of t

21、hese solutionsare given in Test Method D1544 58 T.3Many Glass Standards in currentuse do not conform to the values of Table 1.NOTE 2The precision data were obtained using an instrument inwhich two standards are viewed simultaneously. There are other instru-ments available for color matching which wo

22、uld be expected to givesimilar results, but the statement above applies only to the instrumentchecked.8. Keywords8.1 glass filters; other measurements; transparent standardsAPPENDIX(Nonmandatory Information)X1. CALIBRATION OF GLASS REFERENCE STANDARDSX1.1 Select a dual beam spectrophotometer with a

23、suffi-ciently small light beam at the sample position so that all rayswill pass through the standards to be calibrated. Alternativelyequip the spectrophotometer with a condensing lens to accom-plish this purpose.X1.2 Place the standards in turn in the sample position ofthe spectrophotometer. If the

24、comparator is provided with aseparate green filter in front of the light source, place this filterin the reference beam of the dual beam spectrophotometerduring calibration of each standard.X1.3 Obtain spectral transmittance data for each glassreference standard by following Practice E308.X1.4 From

25、the spectral transmittance data for each refer-ence standard calculate the CIE tristimulus values, X, Y, Z, andthe chromaticity coordinates, x, y, for CIE Illuminant C (seePractice E308).ASTM International takes no position respecting the validity of any patent rights asserted in connection with any

26、 item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical

27、committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at

28、 a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor D

29、rive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).3See 1961 Book of ASTM Standards, Part 8.D1544 04 (2010)2