ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf

上传人:diecharacter305 文档编号:510026 上传时间:2018-12-01 格式:PDF 页数:8 大小:153.75KB
下载 相关 举报
ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf_第1页
第1页 / 共8页
ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf_第2页
第2页 / 共8页
ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf_第3页
第3页 / 共8页
ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf_第4页
第4页 / 共8页
ASTM D1556 D1556M-2015e1 Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method《采用砂锥法的现场土壤密度和单位重量的标准试验方法》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D1556/D1556M 151Standard Test Method forDensity and Unit Weight of Soil in Place by Sand-ConeMethod1This standard is issued under the fixed designation D1556/D1556M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the

2、year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1NOTEEditorially corrected 6.1.5 in

3、January 2016.1. Scope*1.1 This test method may be used to determine the in-placedensity and unit weight of soils using a sand cone apparatus.1.2 This test method is applicable for soils without appre-ciable amounts of rock or coarse materials in excess of 112 in.38 mm in diameter.1.3 This test metho

4、d may also be used for the determinationof the in-place density and unit weight of intact or in situ soils,provided the natural void or pore openings in the soil are smallenough to prevent the sand used in the test from entering thevoids. The soil or other material being tested should havesufficient

5、 cohesion or particle attraction to maintain stable sideson a small hole or excavation, and be firm enough to withstandthe minor pressures exerted in digging the hole and placing theapparatus over it, without deforming or sloughing.1.4 This test method is not suitable for organic, saturated, orhighl

6、y plastic soils that would deform or compress during theexcavation of the test hole. This test method may not besuitable for soils consisting of unbound granular materials thatwill not maintain stable sides in the test hole, soils containingappreciable amounts of coarse material larger than 112 in.

7、38mm, and granular soils having high void ratios.1.5 When materials to be tested contain appreciableamounts of particles larger than 112 in. 38 mm, or when testhole volumes larger than 0.1 ft32830 cm3 are required, TestMethod D4914 or D5030/D5030M is applicable.1.6 UnitsThe values stated in either i

8、nch-pound units orSI units presented in brackets are to be regarded separately asstandard. The values stated in each system may not be exactequivalents; therefore each system shall be used independentlyof the other. Combining values from the two systems mayresult in non-conformance with the standard

9、.1.6.1 The gravitational system of inch-pound units is usedwhen dealing with inch-pound units. In this system, the pound(lbf) represents a unit of force (weight).1.6.2 It is common practice in the engineering profession toconcurrently use units representing both mass and force unlessdynamic calculat

10、ions (F = Ma) are involved. This implicitlycombines two separate systems within a single standard. Thesetest methods have been written using inch-pound units (gravi-tational system); however, conversions are given in the SIsystem. The use of balances or scales recording pounds of mass(lbm), or the r

11、ecording of density in lbm/ft3should not beregarded as nonconformance with this standard.1.6.3 The sieve designations are identified using the “stan-dard” system in accordance with Specification E11, such as 25mm and 75 m, followed by the “alternative” system of 1 in.and No. 200, respectively.1.7 Al

12、l observed and calculated values shall conform to theguidelines for significant digits and rounding established inPractice D6026.1.7.1 For purposes of comparing, a measured or calculatedvalue(s) with specified limits, the measured or calculatedvalue(s) shall be rounded to the nearest decimal or sign

13、ificantdigits in the specified limits.1.7.2 The procedures used to specify how data are collected/recorded or calculated in this standard are regarded as theindustry standard. In addition, they are representative of thesignificant digits that generally should be retained. The proce-dures used do not

14、 consider material variation, purpose forobtaining the data, special purpose studies, or any consider-ations for the users objectives; and it is common practice toincrease or reduce significant digits or reported data to becommensurate with these considerations. It is beyond the scopeof this standar

15、d to consider significant digits used in analyticalmethods for engineering design.1This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.08 on Special andConstruction Control Tests.Current edition approved Feb. 1, 2015. P

16、ublished March 2015. Originallyapproved in 1958. Last previous edition approved in 2007 as D1556 07. DOI:10.1520/D1556_D1556M-15E01.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Uni

17、ted States11.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. R

18、eferenced Documents2.1 ASTM Standards:2C136 Test Method for Sieve Analysis of Fine and CoarseAggregatesD653 Terminology Relating to Soil, Rock, and ContainedFluidsD698 Test Methods for Laboratory Compaction Character-istics of Soil Using Standard Effort (12 400 ft-lbf/ft3(600kN-m/m3)D1557 Test Metho

19、ds for Laboratory Compaction Character-istics of Soil Using Modified Effort (56,000 ft-lbf/ft3(2,700 kN-m/m3)D2216 Test Methods for Laboratory Determination of Water(Moisture) Content of Soil and Rock by MassD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of

20、Soil and Rock asUsed in Engineering Design and ConstructionD4253 Test Methods for Maximum Index Density and UnitWeight of Soils Using a Vibratory TableD4254 Test Methods for Minimum Index Density and UnitWeight of Soils and Calculation of Relative DensityD4643 Test Method for Determination of Water

21、(Moisture)Content of Soil by Microwave Oven HeatingD4718 Practice for Correction of Unit Weight and WaterContent for Soils Containing Oversize ParticlesD4753 Guide for Evaluating, Selecting, and Specifying Bal-ances and Standard Masses for Use in Soil, Rock, andConstruction Materials TestingD4914 Te

22、st Methods for Density and Unit Weight of Soiland Rock in Place by the Sand Replacement Method in aTest PitD4944 Test Method for Field Determination of Water (Mois-ture) Content of Soil by the Calcium Carbide Gas PressureTesterD4959 Test Method for Determination of Water Content ofSoil By Direct Hea

23、tingD5030/D5030M Test Methods for Density of Soil and Rockin Place by the Water Replacement Method in a Test PitD6026 Practice for Using Significant Digits in GeotechnicalDataE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 DefinitionsFor definitions of common techni

24、cal termsin this standard, refer to Terminology D653.3.2 Definitions of Terms Specific to This Standard:3.2.1 compacted lift, na layer of compacted soil.4. Summary of Test Method4.1 A test hole is hand excavated in the soil to be tested andall the material from the hole is saved in a container. The

25、holeis filled with free flowing sand of a known density, and thevolume is determined. The in-place wet density of the soil isdetermined by dividing the wet mass of the removed materialby the volume of the hole. The water content of the materialfrom the hole is determined and the dry mass and the dry

26、density of the in-place material are calculated using the wetmass of the soil, the water content, and the volume of the hole.5. Significance and Use5.1 This test method is used to determine the density andwater content of compacted soils placed during the construc-tion of earth embankments, road fil

27、l, and structural backfill. Itoften is used as a basis of acceptance for soils compacted to aspecified density or percentage of a maximum density deter-mined by a test method, such as Test Methods D698 or D1557.5.1.1 Test Methods D698 and D1557 require that massmeasurements of laboratory compacted t

28、est specimens bedetermined to the nearest 1 g, so that computed water contentsand densities can be reported to three and four significantdigits, respectively. This standard is a field procedure requiringmass measurements to the nearest 0.01 lbm 5 g. As such,water content calculations should only be

29、reported to nearest1 % and density to three significant digits.5.2 This test method can be used to determine the in-placedensity of natural soil deposits, aggregates, soil mixtures, orother similar material.5.3 The use of this test method is generally limited to soil inan unsaturated condition. This

30、 test method is not recommendedfor soils that are soft or friable (crumble easily) or in moistureconditions such that water seeps into the hand excavated hole.The precision of the test may be affected for soils that deformeasily or that may undergo a volume change in the excavatedhole from vibration

31、, or from standing or walking near the holeduring the test (see Note 1).NOTE 1When testing in soft conditions or in soils near saturation,volume changes may occur in the excavated hole as a result of surfaceloading, personnel performing the test, and the like. This can sometimesbe avoided by the use

32、 of a platform that is supported some distance fromthe hole. As it is not always possible to detect when a volume change hastaken place, test results should always be compared to the theoreticalsaturation density, or the zero air voids line on the dry density versus watercontent plot. Any in-place d

33、ensity test on compacted soils that calculatesto be more than 95 % saturation is suspect and an error has probablyoccurred, or the volume of the hole has changed during testing.NOTE 2The quality of the test result producted by this test method isdependent on the competence of the personnel performin

34、g it, and thesuitability of the equipment and facilities used. Agencies that meet thecriteria of Practice D3740 are generally considered capable of competentand objective testing/sampling/inspection, and the like. Users of this testmethod are cautioned that compliance with Practice D3740 does not in

35、itself ensure reliable results. Reliable results depend on many factors;Practice D3740 provides a means of evaluating some of those factors.6. Apparatus6.1 Sand-Cone Density Apparatus, consisting of sandcontainer, sand cone, and base plate.2For referenced ASTM standards, visit the ASTM website, www.

36、astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.D1556/D1556M 15126.1.1 Sand Container, an attachable jar or other sand con-tainer having a volume capacity in excess of t

37、hat required to fillthe test hole and sand cone during the test.6.1.2 Sand Cone, a detachable appliance consisting of acylindrical valve with an orifice approximately12 in. 13 mmin diameter, attached to a metal funnel and sand container onone end, and a large metal funnel (sand-cone) on the other en

38、d.The valve will have stops to prevent rotating past the com-pletely open or completely closed positions. The appliance willbe constructed of metal sufficiently rigid to prevent distortionor volume changes in the cone. The walls of the cone will forman angle of approximately 60 with the base to allo

39、w uniformfilling with sand.6.1.3 Base Plate, a metal base plate or template with aflanged center hole cast or machined to receive the large funnel(cone) of the appliance described in 6.1.2. The base plate maybe round or square and will be a minimum of 3 in. 75 mmlarger than the funnel (sand-cone). T

40、he plate will be flat on thebottom and have sufficient thickness or stiffness to be rigid.Plates with raised edges, ridges, ribs, or other stiffeners ofapproximately38 to12 in. 10 to 13 mm high may be used.6.1.4 The mass of the sand required to fill the sand cone andbase plate will be determined in

41、accordance with the instruc-tions in Annex A1 prior to use.6.1.5 The details for the apparatus shown in Fig. 1 repre-sents the minimum acceptable dimensions suitable for testingsoils having maximum particle sizes of approximately 112 in.38 mm and test hole volumes of approximately 0.1 ft32830cm3. Wh

42、en the material being tested contains a small amountof oversize and isolated larger particles are encountered, thetest should be stopped and moved to a new location. Largerapparatus and test hole volumes are needed when particleslarger than 112 in. 38 mm are prevalent. The apparatusdescribed here re

43、presents a design that has proven satisfactory.Larger apparatus, or other designs of similar proportions maybe used as long as the basic principles of the sand volumedetermination are observed. When test hole volumes largerthan 0.1 ft32830 cm3 are required. Test Method D4914should be utilized.6.2 Sa

44、ndSand must be clean, dry, uniform in density andgrading, uncemented, durable, and free-flowing. Any gradationmay be used that has a coefficient of uniformity (Cu = D60/D10)less than 2.0, a maximum particle size smaller than the 2.0 mmNo. 10 sieve size, and less than 3 % by weight passing the250 m N

45、o. 60 sieve size, determined in accordance with TestMethod C136. Uniformly graded sand is needed to preventsegregation during handling, storage, and use. Sand free offines and fine sand particles is required to prevent significantbulk-density changes with normal daily changes in atmo-spheric humidit

46、y. Sand comprised of durable, naturalsubrounded, or rounded particles is desirable. Crushed sand orsand having angular particles may not be free-flowing, acondition that can cause bridging resulting in inaccuratedensity determinations (see Note 3). In selecting a sand from apotential source, a grada

47、tion and bulk-density determinationsin accordance with the procedure in Annex A2 should be madeon each container or bag of sand. To be an acceptable sand, thebulk-density variation between any one determination shall notbe greater than 1 % of the average. Before using sand indensity determinations,

48、it shall be dried, then allowed to reachan air-dried state in the general location where it is to be used(see Note 4). Sand shall not be re-used without removing anycontaminating soil, checking the gradation, drying and rede-termining the bulk-density (see Note 5). Bulk-density tests ofthe sand will

49、 be made at time intervals not exceeding 14 days,always after any significant changes in atmospheric humidity,before reusing, and before use of a new batch from apreviously approved supplier (see Note 6).NOTE 3Some manufactured (crushed) sands such as blasting sandhave been successfully used with good reproducibility. The reproducibilityof test results using angular sand should be checked under laboratorycontrolled testing situations before selecting an angular sand for use.NOTE 4Many organizations have found it beneficial to s

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1