ASTM D2295-1996(2008) Standard Test Method for Strength Properties of Adhesives in Shear by Tension Loading at Elevated Temperatures (Metal-to-Metal)《高温下用拉力负荷法测定金属之间胶粘剂剪切强度的标准试验方法》.pdf

上传人:孙刚 文档编号:511413 上传时间:2018-12-01 格式:PDF 页数:3 大小:76.89KB
下载 相关 举报
ASTM D2295-1996(2008) Standard Test Method for Strength Properties of Adhesives in Shear by Tension Loading at Elevated Temperatures (Metal-to-Metal)《高温下用拉力负荷法测定金属之间胶粘剂剪切强度的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM D2295-1996(2008) Standard Test Method for Strength Properties of Adhesives in Shear by Tension Loading at Elevated Temperatures (Metal-to-Metal)《高温下用拉力负荷法测定金属之间胶粘剂剪切强度的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM D2295-1996(2008) Standard Test Method for Strength Properties of Adhesives in Shear by Tension Loading at Elevated Temperatures (Metal-to-Metal)《高温下用拉力负荷法测定金属之间胶粘剂剪切强度的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 2295 96 (Reapproved 2008)Standard Test Method forStrength Properties of Adhesives in Shear by TensionLoading at Elevated Temperatures (Metal-to-Metal)1This standard is issued under the fixed designation D 2295; the number immediately following the designation indicates the year oforig

2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the com-parative

3、shear strengths of adhesives for bonding metals whentested on a standard specimen and under specified conditions ofpreparation and testing at elevated temperatures.1.2 This test method is applicable to the temperature rangefrom 315 to 850C (600 to 1500F).1.3 The values stated in SI units are to be r

4、egarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to consult andestablish appropriate safety and health practic

5、es and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 167 Specification for Stainless and Heat-ResistingChromium-Nickel Steel Plate, Sheet, and StripD 638 Test Method for Tensile Properties of PlasticsD 907 Terminology of AdhesivesD 1

6、002 Test Method for Apparent Shear Strength of Single-Lap-Joint Adhesively Bonded Metal Specimens by Ten-sion Loading (Metal-to-Metal)2.2 Military Specifications:MIL-S-25043 Steel Plate, Sheet, and Strip33. Terminology3.1 Many terms in this test method are defined in Terminol-ogy D 907.4. Significan

7、ce and Use4.1 Comparative strength of adhesive bonds at elevatedtemperatures allows for better selection of adhesives that mustperform at temperatures above normal. This test method isuseful in supplying such information.5. Apparatus5.1 Testing Machine, conforming to the requirements of TestMethod D

8、 638. Use pin-type grips as shown in Fig. 1 to holdthe test specimen.5.2 Heating Equipment, consisting of a radiant heat source,backed by a high-efficiency reflector for the purpose ofobtaining the desired heat flux. A suitable lamp arrangementfor heating a specimen is shown in Fig. 2.6. Test Specim

9、ens6.1 Cut test specimens from panels shown in Fig. 3(a).These test specimens form and dimensions are shown in Fig.3(b). The specimens are similar to the tension lap shearspecimen described in Fig. 1 of Test Method D 1002, exceptthat pin-type grips are used.6.2 Base the selection of materials on the

10、 test temperaturerange. The following grades of steel are recommended, al-though use of other types of heat-resistant steel is permitted:Metal DesignationSteel, corrosion-resistant (18-8) plate, sheet, andstripA 167, Type 302Steel plate, sheet, and strip 17-7PH, TH 1050, cor-rosion-resistant, precip

11、itation hardenedMIL-S-25043The nominal thickness for the sheet 1.270 mm (0.050 in.).7. Preparation of Test Specimens7.1 Cut test specimens as shown in Fig. 3(b) to dimensionsfrom the test panel. Measure the width of the specimen and thelength of the overlap to the nearest 0.25 mm (0.01 in.).1This te

12、st method is under the jurisdiction of ASTM Committee D14 onAdhesives and is the direct responsibility of Subcommittee D14.80 on MetalBonding Adhesives.Current edition approved April 1, 2008. Published April 2008. Originallyapproved in 1964. Last previous edition approved in 2002 as D 2295 96 (2002)

13、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP

14、, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 Prepare test specimens by bonding individual strips asshown in Fig. 3(b). Machine unbon

15、ded individual strips to sizeand free from burrs or other irregularities.7.3 Uniformly coat both sides of the dummy and testspecimens with carbon black as shown in Fig. 3(b).8. Procedure8.1 Place the specimens in the pin-type grips of the testingmachine so that the long axis of the test specimen coi

16、ncideswith the direction of applied pull through the center line of thegrip assembly.8.2 Heat the specimen uniformly in the bond area using aradiant source. Ensure that the required bondline temperature isreached within a prescribed period of time.8.3 Perform a temperature calibration on a dummy spe

17、ci-men prior to test. Calibrate the bond temperature using twothermocouples positioned in the geometric center of the bond.Embed one thermocouple in the center of the bond andsuperimpose and bond or spot weld the other to the outersurface (Fig. 4). If spot welding is employed, do this in such away a

18、s not to cause damage to the bond. Bring the bond totemperature using the embedded thermocouple as the monitorand simultaneously recording the external temperature.8.4 Test the specimen as follows:8.4.1 Allow no slack in the test fixture just prior to applyingload. If a preload is used, do not excee

19、d 345 kPa (50 psi) atambient temperature.8.4.2 Control the temperature by the external thermocouplewhich has been calibrated in accordance with 6.2.8.4.3 Establish the heating rate and time at steady state forbondline temperature.8.4.4 The test temperature tolerance is 61%.8.4.5 Unless otherwise spe

20、cified, load the test specimen tofailure at a rate of 8.3 to 9.7 MPa (1200 to 1400 psi)/min.8.5 Record the load at failure and the nature and amount ofthis failure (cohesion in adhesive or metal, or adhesion) foreach specimen. Express all failing loads in megapascals (orpounds-force per square inch)

21、 and if possible, report to threesignificant figures.9. Report9.1 Report the following information:9.1.1 Complete identification of the adhesive tested, includ-ing type, source, manufacturers code numbers, form, and soforth,FIG. 1 Specimen HolderFIG. 2 Heat Lamp Arrangement(a)(b)FIG. 3 Form and Dime

22、nsion of Bonded Panel and Test SpecimenFIG. 4 Thermocouple LocationD 2295 96 (2008)29.1.2 Complete identification of the metal used, its thick-ness, and the method of cleaning and preparing its surfacesprior to bonding,9.1.3 Application and bonding conditions used in preparingthe specimens,9.1.4 Len

23、gth of overlap used,9.1.5 Conditioning procedure used for specimens prior totesting,9.1.6 Test temperature,9.1.7 Number of specimens tested,9.1.8 Number of joints represented,9.1.9 Maximum, minimum, and average values for the loadat failure,9.1.10 Nature of the failure, including the average estimat

24、edpercent of failure in the cohesion of the adhesive, contactfailure, and adhesion to the metal, and9.1.11 Average thickness of adhesive layer after formationof the joint, within 0.025 mm (0.001 in.). The method ofobtaining the thickness of the adhesive layer shall be describedincluding procedure, l

25、ocation of measurements, and range ofmeasurements.10. Precision and Bias10.1 A precision and bias statement does not exist for thistest method because resources necessary for round-robin test-ing have not been forthcoming.11. Keywords11.1 elevated-temperature; metal; shear; tensionASTM International

26、 takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their ow

27、n responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be ad

28、dressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, a

29、t the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 2295 96 (2008)3