1、Designation: D346 04 (Reapproved 2010)Standard Practice forCollection and Preparation of Coke Samples for LaboratoryAnalysis1This standard is issued under the fixed designation D346; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONCoke, especially run of oven coke or foundry coke, or both, is a difficult material to sample. It isimpera
3、tive that every sample be collected and handled carefully and conscientiously and in strictaccordance with the standard procedure described herein.Gross samples of not less than the quantities designated in this practice must be taken, whether thecoke to be sampled consists of a few tons or several
4、hundred tons.1. Scope1.1 This practice covers procedures for the collection andreduction of samples of coke to be used for physical tests,chemical analyses, and the determination of total moisture.1.2 The values given in SI units are to be regarded as thestandard. The values given in parentheses are
5、 for informationonly.1.3 This standard does not purport to address the safetyconcerns associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Reference
6、d Documents2.1 ASTM Standards:2D167 Test Method for Apparent and True Specific Gravityand Porosity of Lump CokeD293 Test Method for the Sieve Analysis of CokeD2013 Practice for Preparing Coal Samples for AnalysisD2234/D2234M Practice for Collection of a Gross Sampleof CoalD3038 Test Method for Drop
7、Shatter Test for CokeD3302 Test Method for Total Moisture in CoalD3402 Test Method for Tumbler Test for CokeD6883 Practice for Manual Sampling of Stationary Coalfrom Railroad Cars, Barges, Trucks, or Stockpiles3. Significance and Use3.1 This practice may be used to provide a representativesample of
8、the coke from which it is collected. Because of thevariability of coke and the wide variety of sampling equipment,caution must be exercised in all stages of sampling, fromsystem specifications and equipment procurement to equip-ment acceptance testing and actually taking the final sample.3.2 This pr
9、actice also provides an analysis sample of cokefrom the gross or divided sample. The analysis samples can beused to determine the value of the coke represented, its abilityto meet specifications, as well as for other purposes.4. Place of Sampling4.1 Sample coke while it is being loaded into or unloa
10、dedfrom railroad cars, ships, barges, or trucks, or when dischargedfrom supply bins, grab buckets, belt conveyers, or other cokeconveying equipment. Sample close to the point of interest.5. Collection of Gross Sample5.1 Collect increments regularly, systematically, and withsuch frequency, so that th
11、e entire quantity of coke sampled willbe represented proportionately in the gross sample, and a grosssample of the required amount will be collected. The standardgross sample shall equal or exceed the quantities given in Table1.5.1.1 The quantity of sample to be taken will depend on thesize of the c
12、oke being sampled and the amount of informationto be obtained from the sample.5.1.1.1 The size of the sieve analysis sample is governed bythe homogeneity of the coke being sampled. The quantitiesgiven in Table 1 represent the minimum quantity to be1This practice is under the jurisdiction of ASTM Com
13、mittee D05 on Coal andCoke and is the direct responsibility of Subcommittee D05.23 on Sampling.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1932. Last previous edition approved in 2004 as D346 04e1. DOI:10.1520/D0346-04R10.2For referenced ASTM standards, visit the
14、ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Un
15、ited States.collected. The sieve analysis sample will supply sufficient cokefor any subsequent physical tests and laboratory analysis. Totalmoisture of the coke should not be determined on the sieveanalysis sample.5.1.1.2 For the drop shatter test, a minimum of 75 kg (165lb) of coke retained on 50-m
16、m (2-in.) square mesh sieve iffurnace coke is being processed, or 140 kg (300 lb) of cokeretained on 75-mm (3-in.) square mesh sieve if foundry coke isbeing processed, is required. The quantities given in Table 1represent the minimum amounts required of sized coke.5.1.1.3 The tumbler test requires a
17、 minimum of 35 kg (75lb) of coke that will pass a 75-mm (3-in.) square mesh sieveand can be retained on a 50-mm (2-in.) square mesh sieve, orthat which will pass a 64-mm (212-in.) square mesh sieve andcan be retained on a 38-mm (112-in.) square mesh sieve. Thequantities given in Table 1 represent th
18、e minimum amount ofthe required sized coke.5.1.1.4 The apparent specific gravity test required a mini-mum of 23 kg (50 lb) of representative coke pieces. Thequantities given in Table 1 represent the minimum amounts ofthe required coke pieces.5.1.1.5 The determination of total moisture of the cokereq
19、uires approximately 45 kg (100 lb) of coke. The quantitiesgiven in Table 1 represent the minimum amount to be col-lected.5.1.1.6 The quantities given for samples for chemical analy-sis represent the minimum amounts to be collected.NOTE 1Samples collected from the surface of coke in piles, bins, cars
20、,ships, or barges are, in general, unreliable because of size segregation andshould not be used for determining conformance to specifications unlessthe purchaser and the seller so agree. If necessary to collect a sample ofcoke from the surface of a loaded railroad car, take nine equal incrementsabou
21、t 305 mm (1 ft) below the surface. Locate the nine points as shownin Fig. 1. The diameter of the hole must be at least 3 times that of thelargest piece in the shipment.6. Condition of Increment Collection6.1 Four conditions of increment collection are recognized:6.1.1 Condition A (Stopped-Belt Cut),
22、 in which a loadedconveyor belt is stopped and a full cross-section cut withparallel sides is removed from the coke stream. The distancebetween the parallel faces shall not be less than three times thelength of the largest piece.6.1.2 Condition B (Full-Stream Cut), in which a full crosssection is re
23、moved from a moving stream of coke.6.1.3 Condition C (Part-Stream Cut), in which a portion,not a full cross section, is removed from a moving stream ofcoke.6.1.4 Condition D (Stationary Sampling), in which a portionof coke is collected from a pile, a railroad car, a barge, or ashiphold.NOTE 2See Sec
24、tion 6 of Practice D2234/D2234M.7. Size of Increments7.1 To collect increments, use a shovel or specially designedtool or mechanical means for taking equal increments. Whenincrements are collected from the surface of a loaded rail car ortruck shipment, the gross sample shall consist of nine incre-me
25、nts of approximately equal quantity. When increments aretaken from piles, conveyor belts, barges, and so forth, the grosssample shall consist of not less than 25, nor more than 50increments, of approximately equal quantity.NOTE 3When large-size coke, such as foundry coke, is beingsampled, it is like
26、ly that quantities larger than those given in Table 1 willbe collected. However, the minimum number of increments collectedshould not be decreased unless such is agreed upon between the purchaserand the seller.NOTE 4If the sample for chemical analysis is obtained from the sieveanalysis sample, a sam
27、ple not smaller than that shown in Table 1 shouldTABLE 1 Minimum Gross Sample Weights of Coke, kg (lb)UsageFoundry Coke Furnace CokeCoke BreezeARun of Oven Sized Run of Oven SizedSieve analysis (size consist) 364 (800) 227 (500) 227 (500) 182 (400) 45 (100)Drop shatter test 182 (400) 159 (350) 136 (
28、300) 91 (200) .Tumbler test 68 (150) 45 (100) 57 (125) 57 (125) .Apparent specific gravity 46 (100) 46 (100) 46 (100) 46 (100) 23 (50)Coke moisture 46 (100) 46 (100) 46 (100) 46 (100) 23 (50)Chemical analysis 113 (250) 113 (250) 57 (125) 57 (125) 34 (75)ACoke passing a34-in. (19-mm) square hole siev
29、e or smaller top size.FIG. 1 Location of Sampling Points from Exposed Surface of CarD346 04 (2010)2be reconstituted from the size fractions obtained when the sieve analysissample was processed.8. Quantities Represented8.1 Take a gross sample for each 454 Mg (500 tons) orfraction thereof, or in case
30、of larger tonnages, for suchquantities as may be agreed upon. Sample separately each lotof coke arising from a different source or known to be ofdifferent quality or size.9. Processing of the Test Sample9.1 Process samples collected for sieve analysis of coke inaccordance with the procedure given in
31、 Method D293.9.2 Process samples collected for the drop shatter test inaccordance with the procedure given in Method D3038.9.3 Process samples collected for the tumbler test in accor-dance with the procedure given in Method D3402.9.4 Process samples collected for the determination ofapparent specifi
32、c gravity and porosity in accordance with theprocedure given in Test Method D167.9.5 Process samples taken for the determination of totalmoisture in accordance with the procedure given in TestMethod D3302 and Practice D2013.9.6 Prepare samples taken for chemical analysis as directedin Section 10.10.
33、 Preparation of Coke Sample for Laboratory Analysis10.1 Crush, mix, and divide the entire gross sample inquantity to convenient size for transmission to the chemicallaboratory. Crush the sample, preferably by means of jaw orroll crushers, or on a chilled iron or hard steel plate by impactof a tamper
34、, hard bar, or sledge, avoiding all rubbing actions asotherwise the ash yield can be materially increased by theaddition of iron from the sampling apparatus. Do the crushingunder such conditions as to prevent loss of coke or accidentalmixture of foreign matter.10.2 Procedure A, Manual Riffling:10.2.
35、1 Determine the number of passes required in theriffling operation from the total volume of the gross sample andthe minimum permissible weight in accordance with Table 2.10.2.2 Divide the crushed gross sample by using a largeriffle. Riffles properly used will reduce sample variability butcannot elim
36、inate it. Pass the crushed coke through the rifflefrom a feed scoop, feed bucket, or riffle pan having a lip oropening the full length of the riffle. When using any of theabove containers to feed the riffle, spread the crushed cokeevenly in the container, raise the container, and hold it with itsfro
37、nt edge resting on top of the feed chute; then slowly tilt it sothat the coke flows in a uniform stream through the hopperstraight down over the center of the riffle into all the slots,thence, into the riffle pans, one half of the sample beingcollected in each pan. Under no circumstances shovel thes
38、ample into the riffle, or dribble into the riffle from a small-mouth container. Do not allow the crushed coke to build up inor above the riffle slots. If it does not flow freely through theslots, shake or vibrate the riffle to facilitate even flow. Theopening of the riffle slot should be 2.5 to 3 ti
39、mes the size of thelargest particle.10.2.3 After crushing the gross sample of not less than 14 kg(30 lb) (see Table 2) for 4.75-mm (No. 4) sieve size, usingsuitable pulverizing equipment, further reduce this subsampleto 2.36-mm (No. 8) sieve size and divide by riffling to not lessthan the quantity s
40、pecified in Table 3 for 2.36-mm (No. 8) sievesize.10.2.4 With suitable pulverizing equipment, preferably aroll crusher or ball mill, reduce the 2.36-mm (No. 8) sieve sizesubsample to a 250-m (No. 60) sieve size.10.2.5 As an alternative to the procedure given in 10.2.4, the2.36-mm (No. 8) sieve size
41、subsample may be reduced to pass95 % through a 850-m (No. 20) sieve. Divide this subsampleby riffling with the small riffle to not less than the quantityspecified in Table 3, and then reduce to 250-m (No. 60) sievesize as described in 10.2.4.10.2.6 Thoroughly mix the laboratory analysis sample,weigh
42、ing not less than 50 g, preferably, by mechanical means,before extracting portions for analysis.10.3 Procedure B, Hand Division:10.3.1 The method of dividing by hand the quantity of cokein a gross sample shall be carried out as described even thoughthe initial size of coke and impurities may be less
43、 thanindicated in Table 2.10.3.2 Do the progressive crushing and division in theweight of the sample to the quantities indicated in Table 2 bythe following method, which is described and illustrated in theaccompanying Fig. 2, until the maximum size of the coke is 13mm (12 in.), and the quantity is 2
44、7 kg (60 lb). Crush the grosssample to a maximum size of pieces of 50 mm (1 in.).10.3.2.1 Repeat the alternate-shovel method of dividing thegross sample until the sample is divided to approximately 57kg (125 lb) and take care to observe before each division inquantity that the sample has been crushe
45、d to the finenessspecified in Table 2. Shovel the crushed coke into a conical pile(Fig. 2 (2) by depositing each shovelful of coke on top of thepreceding one, and then form into a long pile in the followingmanner: Take a shovelful of coke from the conical pile andspread it out in a straight pile (Fi
46、g. 2 (3A) having a widthequal to the width of the shovel and a length of 1.5 to3m(5to 10 ft). Spread the next shovelful directly over the top of thefirst shovelful, but in the opposite direction, and so on back andTABLE 2 Weights of Coke Samples with CorrespondingCrushing SizesWeight of Sample to Be
47、 DividedLargest Size of Coke and ImpuritiesAllowable in Sample Before Divisionkg lb mm in.113 or over 250 or over 25 157 125 193427 60 131214 30 5 4 meshTABLE 3 Preparation of Sample for Chemical AnalysisCrush to Pass at Least 95 %Through SieveDivide to MinimumWeight, g4.75 mm (No. 4) 20002.36 mm (N
48、o. 8) 500850 m (No. 20) 250250 m (No. 60) (100 %through)50D346 04 (2010)3forth, piling and, occasionally flattening the pile, until all thecoke has been formed into one long pile, proceeding asfollows: Beginning on one side of the pile, at either end, andshoveling from the bottom of the pile, take o
49、ne shovelful (Fig.2 (4), shovelful No. 1) and set it aside; advancing along the sideof the pile a distance equal to the width of the shovel, take asecond shovelful (shovelful No. 2) and discard it; againadvancing in the same direction one shovel width, take a thirdshovelful (shovelful No. 3) and add it to the first. Take thefourth (shovelful No. 4) in a like manner and discard, retain thefifth (shovelful No. 5), and so on, advancing always in thesame direction around the pile so that its size will be graduallydivided in a uniform manner. When the pile is removed,