ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf

上传人:赵齐羽 文档编号:511684 上传时间:2018-12-01 格式:PDF 页数:8 大小:144.95KB
下载 相关 举报
ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf_第1页
第1页 / 共8页
ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf_第2页
第2页 / 共8页
ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf_第3页
第3页 / 共8页
ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf_第4页
第4页 / 共8页
ASTM D422-1963(2007) Standard Test Method for Particle-Size Analysis of Soils《土壤粒度分析的标准试验方法》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D 422 63 (Reapproved 2007)Standard Test Method forParticle-Size Analysis of Soils1This standard is issued under the fixed designation D 422; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A

2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the quantitative determinationof the distribution of particle sizes in soils. The distribution ofparticle size

3、s larger than 75 m (retained on the No. 200 sieve)is determined by sieving, while the distribution of particle sizessmaller than 75 m is determined by a sedimentation process,using a hydrometer to secure the necessary data (Note 1 andNote 2).NOTE 1Separation may be made on the No. 4 (4.75-mm), No. 4

4、0(425-m), or No. 200 (75-m) sieve instead of the No. 10. For whateversieve used, the size shall be indicated in the report.NOTE 2Two types of dispersion devices are provided: (1) a high-speed mechanical stirrer, and (2) air dispersion. Extensive investigationsindicate that air-dispersion devices pro

5、duce a more positive dispersion ofplastic soils below the 20-m size and appreciably less degradation on allsizes when used with sandy soils. Because of the definite advantagesfavoring air dispersion, its use is recommended. The results from the twotypes of devices differ in magnitude, depending upon

6、 soil type, leading tomarked differences in particle size distribution, especially for sizes finerthan 20 m.2. Referenced Documents2.1 ASTM Standards:2D 421 Practice for Dry Preparation of Soil Samples forParticle-Size Analysis and Determination of Soil Con-stantsE11 Specification for Wire Cloth and

7、 Sieves for TestingPurposesE 100 Specification for ASTM Hydrometers2.2 ASTM Adjuncts:Air-Jet Dispersion Cup for Grain-Size Analysis of Soil33. Apparatus3.1 BalancesA balance sensitive to 0.01 g for weighingthe material passing a No. 10 (2.00-mm) sieve, and a balancesensitive to 0.1 % of the mass of

8、the sample to be weighed forweighing the material retained on a No. 10 sieve.3.2 Stirring ApparatusEither apparatus A or B may beused.3.2.1 Apparatus A shall consist of a mechanically operatedstirring device in which a suitably mounted electric motor turnsa vertical shaft at a speed of not less than

9、 10 000 rpm withoutload. The shaft shall be equipped with a replaceable stirringpaddle made of metal, plastic, or hard rubber, as shown in Fig.1. The shaft shall be of such length that the stirring paddle willoperate not less than34 in. (19.0 mm) nor more than 112 in.(38.1 mm) above the bottom of th

10、e dispersion cup. A specialdispersion cup conforming to either of the designs shown inFig. 2 shall be provided to hold the sample while it is beingdispersed.3.2.2 Apparatus B shall consist of an air-jet dispersion cup(See drawing3)(Note 3) conforming to the general detailsshown in Fig. 3 (Note 4 and

11、 Note 5).NOTE 3The amount of air required by an air-jet dispersion cup is ofthe order of 2 ft3/min; some small air compressors are not capable ofsupplying sufficient air to operate a cup.NOTE 4Another air-type dispersion device, known as a dispersiontube, developed by Chu and Davidson at Iowa State

12、College, has beenshown to give results equivalent to those secured by the air-jet dispersioncups. When it is used, soaking of the sample can be done in thesedimentation cylinder, thus eliminating the need for transferring theslurry. When the air-dispersion tube is used, it shall be so indicated in t

13、hereport.NOTE 5Water may condense in air lines when not in use. This watermust be removed, either by using a water trap on the air line, or byblowing the water out of the line before using any of the air for dispersionpurposes.3.3 HydrometerAn ASTM hydrometer, graduated to readin either specific gra

14、vity of the suspension or grams per litre ofsuspension, and conforming to the requirements for hydrom-eters 151H or 152H in Specifications E 100. Dimensions ofboth hydrometers are the same, the scale being the only item ofdifference.1This test method is under the jurisdiction ofASTM Committee D18 on

15、 Soil andRock and is the direct responsibility of Subcommittee D18.03 on Texture, Plasticityand Density Characteristics of Soils.Current edition approved Oct. 15, 2007. Published October 2007. Originallyapproved in 1935. Last previous edition approved in 2002 as D 422 63 (2002)e1.2For referenced AST

16、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJD0422.1Copy

17、right ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.4 Sedimentation CylinderAglass cylinder essentially 18in. (457 mm) in height and 212 in. (63.5 mm) in diameter, andmarked for a volume of 1000 mL. The inside diameter shall besuch that the

18、 1000-mL mark is 36 6 2 cm from the bottom onthe inside.3.5 ThermometerA thermometer accurate to 1F (0.5C).3.6 SievesA series of sieves, of square-mesh woven-wirecloth, conforming to the requirements of Specification E11.Afull set of sieves includes the following (Note 6):3-in. (75-mm) No. 10 (2.00-

19、mm)2-in. (50-mm) No. 20 (850-m)112-in. (37.5-mm) No. 40 (425-m)1-in. (25.0-mm) No. 60 (250-m)34-in. (19.0-mm) No. 140 (106-m)38-in. (9.5-mm) No. 200 (75-m)No. 4 (4.75-mm)NOTE 6Aset of sieves giving uniform spacing of points for the graph,as required in Section 17, may be used if desired. This set co

20、nsists of thefollowing sieves:3-in. (75-mm) No. 16 (1.18-mm)112-in. (37.5-mm) No. 30 (600-m)34-in. (19.0-mm) No. 50 (300-m)38-in. (9.5-mm) No. 100 (150-m)No. 4 (4.75-mm) No. 200 (75-m)No. 8 (2.36-mm)3.7 Water Bath or Constant-Temperature RoomA waterbath or constant-temperature room for maintaining t

21、he soilsuspension at a constant temperature during the hydrometeranalysis. A satisfactory water tank is an insulated tank thatmaintains the temperature of the suspension at a convenientconstant temperature at or near 68F (20C). Such a device isillustrated in Fig. 4. In cases where the work is perfor

22、med in aroom at an automatically controlled constant temperature, thewater bath is not necessary.3.8 BeakerA beaker of 250-mL capacity.3.9 Timing DeviceA watch or clock with a second hand.4. Dispersing Agent4.1 A solution of sodium hexametaphosphate (sometimescalled sodium metaphosphate) shall be us

23、ed in distilled ordemineralized water, at the rate of 40 g of sodiumhexametaphosphate/litre of solution (Note 7).NOTE 7Solutions of this salt, if acidic, slowly revert or hydrolyzeback to the orthophosphate form with a resultant decrease in dispersiveaction. Solutions should be prepared frequently (

24、at least once a month) oradjusted to pH of 8 or 9 by means of sodium carbonate. Bottles containingMetric Equivalentsin. 0.001 0.049 0.2031234mm 0.03 1.24 5.16 12.7 19.0FIG. 1 Detail of Stirring PaddlesMetric Equivalentsin. 1.3 2.6 3.75mm 33 66 95.2FIG. 2 Dispersion Cups of ApparatusD 422 63 (2007)2s

25、olutions should have the date of preparation marked on them.4.2 All water used shall be either distilled or demineralizedwater. The water for a hydrometer test shall be brought to thetemperature that is expected to prevail during the hydrometertest. For example, if the sedimentation cylinder is to b

26、e placedin the water bath, the distilled or demineralized water to beused shall be brought to the temperature of the controlled waterbath; or, if the sedimentation cylinder is used in a room withcontrolled temperature, the water for the test shall be at thetemperature of the room. The basic temperat

27、ure for thehydrometer test is 68F (20C). Small variations of tempera-ture do not introduce differences that are of practical signifi-cance and do not prevent the use of corrections derived asprescribed.5. Test Sample5.1 Prepare the test sample for mechanical analysis asoutlined in Practice D 421. Du

28、ring the preparation procedurethe sample is divided into two portions. One portion containsonly particles retained on the No. 10 (2.00-mm) sieve while theother portion contains only particles passing the No. 10 sieve.The mass of air-dried soil selected for purpose of tests, asprescribed in Practice

29、D 421, shall be sufficient to yieldquantities for mechanical analysis as follows:5.1.1 The size of the portion retained on the No. 10 sieveshall depend on the maximum size of particle, according to thefollowing schedule:Nominal Diameter ofLargest Particles,in. (mm)Approximate MinimumMass of Portion,

30、 g38 (9.5) 50034 (19.0) 10001 (25.4) 2000112 (38.1) 30002 (50.8) 40003 (76.2) 50005.1.2 The size of the portion passing the No. 10 sieve shallbe approximately 115 g for sandy soils and approximately 65g for silt and clay soils.FIG. 3 Air-Jet Dispersion Cups of Apparatus BMetric Equivalentsin.78 1361

31、4 14 37mm 22.2 25.4 76.2 158.2 356 940FIG. 4 Insulated Water BathD 422 63 (2007)35.2 Provision is made in Section 5 of Practice D 421 forweighing of the air-dry soil selected for purpose of tests, theseparation of the soil on the No. 10 sieve by dry-sieving andwashing, and the weighing of the washed

32、 and dried fractionretained on the No. 10 sieve. From these two masses thepercentages retained and passing the No. 10 sieve can becalculated in accordance with 12.1.NOTE 8A check on the mass values and the thoroughness of pulveri-zation of the clods may be secured by weighing the portion passing the

33、No. 10 sieve and adding this value to the mass of the washed andoven-dried portion retained on the No. 10 sieve.SIEVE ANALYSIS OF PORTION RETAINED ON NO.10(2.00-mm) SIEVE6. Procedure6.1 Separate the portion retained on the No. 10 (2.00-mm)sieve into a series of fractions using the 3-in. (75-mm), 2-i

34、n.(50-mm), 112-in. (37.5-mm), 1-in. (25.0-mm),34-in. (19.0-mm),38-in. (9.5-mm), No. 4 (4.75-mm), and No. 10 sieves, oras many as may be needed depending on the sample, or uponthe specifications for the material under test.6.2 Conduct the sieving operation by means of a lateral andvertical motion of

35、the sieve, accompanied by a jarring action inorder to keep the sample moving continuously over the surfaceof the sieve. In no case turn or manipulate fragments in thesample through the sieve by hand. Continue sieving until notmore than 1 mass % of the residue on a sieve passes that sieveduring 1 min

36、 of sieving. When mechanical sieving is used, testthe thoroughness of sieving by using the hand method ofsieving as described above.6.3 Determine the mass of each fraction on a balanceconforming to the requirements of 3.1. At the end of weighing,the sum of the masses retained on all the sieves used

37、shouldequal closely the original mass of the quantity sieved.HYDROMETER AND SIEVE ANALYSIS OF PORTIONPASSING THE NO. 10 (2.00-mm) SIEVE7. Determination of Composite Correction forHydrometer Reading7.1 Equations for percentages of soil remaining in suspen-sion, as given in 14.3, are based on the use

38、of distilled ordemineralized water. A dispersing agent is used in the water,however, and the specific gravity of the resulting liquid isappreciably greater than that of distilled or demineralizedwater.7.1.1 Both soil hydrometers are calibrated at 68F (20C),and variations in temperature from this sta

39、ndard temperatureproduce inaccuracies in the actual hydrometer readings. Theamount of the inaccuracy increases as the variation from thestandard temperature increases.7.1.2 Hydrometers are graduated by the manufacturer to beread at the bottom of the meniscus formed by the liquid on thestem. Since it

40、 is not possible to secure readings of soilsuspensions at the bottom of the meniscus, readings must betaken at the top and a correction applied.7.1.3 The net amount of the corrections for the three itemsenumerated is designated as the composite correction, and maybe determined experimentally.7.2 For

41、 convenience, a graph or table of composite correc-tions for a series of 1 temperature differences for the range ofexpected test temperatures may be prepared and used asneeded. Measurement of the composite corrections may bemade at two temperatures spanning the range of expected testtemperatures, an

42、d corrections for the intermediate temperaturescalculated assuming a straight-line relationship between thetwo observed values.7.3 Prepare 1000 mL of liquid composed of distilled ordemineralized water and dispersing agent in the same propor-tion as will prevail in the sedimentation (hydrometer) test

43、.Place the liquid in a sedimentation cylinder and the cylinder inthe constant-temperature water bath, set for one of the twotemperatures to be used. When the temperature of the liquidbecomes constant, insert the hydrometer, and, after a shortinterval to permit the hydrometer to come to the temperatu

44、re ofthe liquid, read the hydrometer at the top of the meniscusformed on the stem. For hydrometer 151H the compositecorrection is the difference between this reading and one; forhydrometer 152H it is the difference between the reading andzero. Bring the liquid and the hydrometer to the other tempera

45、-ture to be used, and secure the composite correction as before.8. Hygroscopic Moisture8.1 When the sample is weighed for the hydrometer test,weigh out an auxiliary portion of from 10 to 15 g in a smallmetal or glass container, dry the sample to a constant mass inan oven at 230 6 9F (110 6 5C), and

46、weigh again. Recordthe masses.9. Dispersion of Soil Sample9.1 When the soil is mostly of the clay and silt sizes, weighout a sample of air-dry soil of approximately 50 g. When thesoil is mostly sand the sample should be approximately 100 g.9.2 Place the sample in the 250-mL beaker and cover with125

47、mL of sodium hexametaphosphate solution (40 g/L). Stiruntil the soil is thoroughly wetted. Allow to soak for at least 16h.9.3 At the end of the soaking period, disperse the samplefurther, using either stirring apparatus A or B. If stirringapparatus A is used, transfer the soil-water slurry from theb

48、eaker into the special dispersion cup shown in Fig. 2, washingany residue from the beaker into the cup with distilled ordemineralized water (Note 9). Add distilled or demineralizedwater, if necessary, so that the cup is more than half full. Stirfor a period of 1 min.NOTE 9A large size syringe is a c

49、onvenient device for handling thewater in the washing operation. Other devices include the wash-waterbottle and a hose with nozzle connected to a pressurized distilled watertank.9.4 If stirring apparatus B (Fig. 3) is used, remove the covercap and connect the cup to a compressed air supply by meansof a rubber hose. A air gage must be on the line between thecup and the control valve. Open the control valve so that thegage indicates 1 psi (7 kPa) pressure (Note 10). Transfer theD 422 63 (2007)4soil-water slurry from the

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1