1、Designation: D56 16Standard Test Method forFlash Point by Tag Closed Cup Tester1This standard is issued under the fixed designation D56; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parenth

2、eses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.INTRODUCTIONTo ensure an acceptable precision, this dynamic flash point test m

3、ethod employs a prescribed rateof temperature rise for the material under test. The rate of heating may not in all cases give theprecision quoted in the test method because of the low thermal conductivity of certain materials. Toimprove the prediction of flammability, Test Method D3941, which utiliz

4、es a slower heating rate, wasdeveloped. Test Method D3941 provides conditions closer to equilibrium where the vapor above theliquid and the liquid are at about the same temperature. If a specification requires Test Method D56,do not change to Test Method D3941 or other test method without permission

5、 from the specifier.Flash point values are a function of the apparatus design, the condition of the apparatus used, andthe operational procedure carried out. Flash point can therefore only be defined in terms of a standardtest method, and no general valid correlation can be guaranteed between result

6、s obtained by differenttest methods, or with test apparatus different from that specified.1. Scope*1.1 This test method covers the determination of the flashpoint, by tag manual and automated closed testers, of liquidswith a viscosity below 5.5 mm2/s (cSt) at 40 C (104 F), orbelow 9.5 mm2/s (cSt) at

7、 25 C (77 F), and a flash point below93 C (200 F).1.1.1 For the closed-cup flash point of liquids with thefollowing properties: a viscosity of 5.5 mm2/s (cSt) or more at40 C (104 F); a viscosity of 9.5 mm2/s (cSt) or more at 25 C(77 F); a flash point of 93 C (200 F) or higher; a tendency toform a su

8、rface film under test conditions; or containingsuspended solids, Test Method D93 can be used.1.1.2 For cut-back asphalts refer to Test Methods D1310and D3143.NOTE 1The U.S. Department of Transportation (RSTA)2and U.S.Department of Labor (OSHA) have established that liquids with a flashpoint under 37

9、.8 C (100 F) are flammable as determined by this testmethod for those liquids that have a viscosity less than 5.5 mm2/s (cSt) at40 C (104 F) or 9.5 mm2/s (cSt) or less at 25 C (77 F), or do notcontain suspended solids or do not have a tendency to form a surface filmwhile under test. Other flash poin

10、t classifications have been established bythese departments for liquids using this test method.1.2 This test method can be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andcannot be used to describ

11、e or appraise the fire hazard or firerisk of materials, products, or assemblies under actual fireconditions. However, results of this test method can be used aselements of fire risk assessment that takes into account all ofthe factors that are pertinent to an assessment of the fire hazardof a partic

12、ular end use.1.3 Related standards are Test Methods D93, D1310,D3828, D3278, and D3941.1.4 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.5 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material th

13、at can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAsweb

14、sitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling mercury1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.08 on Volatility.Curren

15、t edition approved June 1, 2016. Published June 2016. Originallyapproved in 1918. Last previous edition approved in 2010 as D56 05 (2010). DOI:10.1520/D0056-16.2For information on United States Department of Transportation regulations, seeCodes of United States Regulation 49 CFR Chapter 1 and for in

16、formation on UnitedStates Department of Labor regulations, see Code of United States Regulation 29CFR Chapter XVII. Each of these items are revised annually and may be procuredfrom the Superintendent of Documents, Government Printing Office, Washington,DC 20402.*A Summary of Changes section appears

17、at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1and/or mercury containing products into your state or countrymay be prohibited by law.1.6 This standard does not purport to address all of thesafety concerns,

18、if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements see 8.2, 8.3, 9.5, 12.5, and refer to MaterialSafety Dat

19、a Sheets.2. Referenced Documents2.1 ASTM Standards:3D93 Test Methods for Flash Point by Pensky-MartensClosed Cup TesterD1310 Test Method for Flash Point and Fire Point of Liquidsby Tag Open-Cup ApparatusD3143 Test Method for Flash Point of Cutback Asphalt withTag Open-Cup ApparatusD3278 Test Methods

20、 for Flash Point of Liquids by SmallScale Closed-Cup ApparatusD3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD6299 Practice fo

21、r Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricantsE1 Specification for ASTM Liquid-in-Glass ThermometersE50

22、2 Test Method for Selection and Use of ASTM Stan-dards for the Determination of Flash Point of Chemicalsby Closed Cup Methods2.2 Federal Test Method Standards:4Method 1101, Federal Test Method Standard No. 791bMethod 4291, Federal Test Method Standard No. 141A2.3 ISO Standards:5Guide 34 General Requ

23、irements for the Competence of Ref-erence Material ProducersGuide 35 Certification of Reference MaterialsGeneral andStatistical Principles3. Terminology3.1 Definitions:3.1.1 flash point, nin flash point test methods, the lowesttemperature of the test specimen, adjusted to account forvariations in at

24、mospheric pressure from 101.3 kPa, at whichapplication of an ignition source causes the vapors of the testspecimen to ignite under specified conditions of test.3.1.1.1 DiscussionThe specimen is deemed to haveflashed when a flame appears and instantaneously propagatesitself over the entire surface of

25、 the fluid.3.1.1.2 DiscussionWhen the ignition source is a testflame, the application of the test flame may cause a blue haloor an enlarged flame prior to the actual flash point. This is nota flash and should be ignored.3.2 Definitions of Terms Specific to This Standard:3.2.1 dynamic (non-equilibriu

26、m)in this type of flash pointapparatus, the condition of the vapor above the specimen andthe specimen are not at the same temperature at the time thatthe ignition source is applied.3.2.1.1 DiscussionThis is primarily caused by the heatingof the specimen at the constant prescribed rate with the vapor

27、temperature lagging behind the specimen temperature. Theresultant flash point temperature is generally within the repro-ducibility of the test method.3.2.2 equilibriumin that type of flash point apparatus ortest method, the vapor above the specimen and the specimenare at the same temperature at the

28、time the ignition source isapplied.3.2.2.1 DiscussionThis condition may not be fullyachieved in practice, since the temperature is not uniformthroughout the specimen and the test cover and shutter aregenerally cooler.4. Summary of Test Method4.1 The specimen is placed in the cup of the tester and, w

29、iththe lid closed, heated at a slow constant rate.An ignition sourceis directed into the cup at regular intervals. The flash point istaken as the lowest temperature at which application of theignition source causes the vapor above the specimen to ignite.5. Significance and Use5.1 Flash point measure

30、s the tendency of the specimen toform a flammable mixture with air under controlled laboratoryconditions. It is only one of a number of properties that shall beconsidered in assessing the overall flammability hazard of amaterial.5.2 Flash point is used in shipping and safety regulations todefine fla

31、mmable and combustible materials. One shouldconsult the particular regulation involved for precise defini-tions of these classes.5.3 Flash point can indicate the possible presence of highlyvolatile and flammable materials in a relatively nonvolatile ornonflammable material. For example, an abnormall

32、y low flashpoint on a sample of kerosene can indicate gasoline contami-nation.6. Apparatus (Manual Instrument)6.1 Tag Closed TesterThe apparatus is shown in Fig. 1 anddescribed in detail in Annex A1.6.2 ShieldA shield 460 mm (18 in.) square and 610 mm(24 in.) high, open in front, is recommended.3For

33、 referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from Superintendent of Documents, U.S. Government Prin

34、tingOffice, Washington, DC 20402.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.D561626.3 Temperature Measuring DeviceA liquid-in-glassthermometer, as prescribed in Table 1, or an electronic tem-perature measuring device such as a resistanc

35、e device orthermocouple. The device shall exhibit the same temperatureresponse as the liquid-in-glass thermometer.NOTE 2Whenever thermometers complying withASTM requirementsare not available, thermometers complying with the requirements for TheInstitute of Petroleum thermometer IP 15C PM-Low can be

36、used.7. Sampling7.1 Erroneously high flash points will be obtained whenprecautions are not taken to avoid the loss of volatile material.Containers should not be opened unnecessarily to prevent lossof volatile material and possible introduction of moisture.Transfers should not be made unless the samp

37、le temperature isat least 10 C (18 F) below the expected flash point. Whenpossible, flash point shall be the first test performed on asample and the sample must be stored at low temperature.7.2 Do not store samples in gas-permeable containers sincevolatile materials may diffuse through the walls of

38、the enclo-sure. Samples in leaky containers are suspect and not a sourceof valid results.7.3 At least 50 mL of sample is required for each test. Referto sampling information in Practice D4057.8. Preparation of Apparatus (Manual)8.1 Support the manual apparatus on a level steady surface,such as a tab

39、le. Unless tests are made in a draft-free room orcompartment, surround the tester on three sides by the shieldfor protection from drafts. Tests are not to be made in alaboratory draft hood or near ventilators.8.2 Natural gas and bottled gas flame and electric ignitorshave been found acceptable for u

40、se as the ignition source.(WarningGas pressure supplied to the apparatus must not beallowed to exceed 3 kPa (12 in.) of water pressure.)8.3 For flash points below 13 C (55 F) or above 60 C(140 F), use as a bath liquid a 1 + 1 mixture of water andethylene glycol (WarningEthylene GlycolPoison. Harm-fu

41、l or fatal if swallowed. Vapor harmful. Avoid contact withskin.) For flash points between 13 C (55 F) and 60 C(140 F), either water or a water-glycol mixture can be used asbath liquid. The temperature of the liquid in the bath shall beat least 10 C (18 F) below the expected flash point at the timeof

42、 introduction of the sample into the test cup. Do not cool bathliquid by direct contact with dry ice (solid carbon dioxide).NOTE 3Due to possible difficulty in maintaining the prescribed rate oftemperature rise and due to the formation of ice on the lid, results by thistest method for samples having

43、 flash points below 0 C (32 F) may beunreliable. Trouble due to ice formation on the slide can be minimized bycarefully lubricating the slide shutter with high-vacuum silicone lubricant.8.4 Verify the performance of the manual apparatus (or in11.2.3, the automated apparatus) at least once per year b

44、ydetermining the flash point of a certified reference material(CRM), such as those listed in Annex A2, which is reasonablyclose to the expected temperature range of the samples to betested. The material shall be tested according to the procedureof this test method and the observed flash point obtain

45、ed in 9.5shall be corrected for barometric pressure (see Section 13). Theflash point obtained shall be within the limits stated in TableA2.1 for the identified CRM or within the limits calculated foran unlisted CRM (see Annex A2).8.5 Once the performance of the apparatus has beenverified, the flash

46、point of secondary working standards(SWSs) can be determined along with their control limits.FIG. 1 Tag Closed Flash Tester (Manual)TABLE 1 ThermometersFor testsBelow 4 C(40 F)At4Cto49C(40 F to120 F)Above 49 C(120 F)Use ASTMThermometerA57C or (57F) 9C or (9F)57C or (57F)9C or (9F)AComplete specifica

47、tions for these thermometers are given in Specification E1.D56163These secondary materials can then be utilized for morefrequent performance checks (see Annex A2).8.6 When the flash point obtained is not within the limitsstated in 8.4 or 8.5, check the condition and operation of theapparatus to ensu

48、re conformity with the details listed in AnnexA1, especially with regard to tightness of the lid (see A1.1.3),the action of the shutter, the position of the ignition source (seeA1.1.3.3), and the angle and position of the temperaturemeasuring device (see A1.1.3.4). After any adjustment, repeatthe te

49、st in 8.4 using fresh test specimen, with special attentionto the procedural details prescribed in the test method.9. Procedure (Manual)9.1 Using a graduated cylinder and taking care to avoidwetting the cup above the final liquid level, measure50 mL 6 0.5 mL of the sample into the cup, both the sampleand graduated cylinder being precooled, when necessary, sothat the specimen temperature at the time of measurement willbe 27 C 6 5C(8F6 10 F) or at least 10 C (18 F) belowthe expected flash point, whichever is lower. It

展开阅读全文
相关资源
猜你喜欢
  • ANSI IEEE 1214-1992 Standard Multichannel Analyzer (MCA) Histogram Data Interchange Format for Nuclear Spectroscopy《核能谱学的标准多通道分析器频率分布图数据交换格式》.pdf ANSI IEEE 1214-1992 Standard Multichannel Analyzer (MCA) Histogram Data Interchange Format for Nuclear Spectroscopy《核能谱学的标准多通道分析器频率分布图数据交换格式》.pdf
  • ANSI IEEE 1222-2011 Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines《公用电力设施输电线用全介电自承式(ADSS)光缆标性能和检测标准》.pdf ANSI IEEE 1222-2011 Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines《公用电力设施输电线用全介电自承式(ADSS)光缆标性能和检测标准》.pdf
  • ANSI IEEE 1227-1990 Guide for the Measurement of DC Electric-Field Strength and Ion Related Quantities《直流电场强度和离子相关量的测量指南》.pdf ANSI IEEE 1227-1990 Guide for the Measurement of DC Electric-Field Strength and Ion Related Quantities《直流电场强度和离子相关量的测量指南》.pdf
  • ANSI IEEE 1241-2010 Terminology and Test Methods for Analog-to-Digital Converters《模拟-数字转换器的术语和试验方法标准》.pdf ANSI IEEE 1241-2010 Terminology and Test Methods for Analog-to-Digital Converters《模拟-数字转换器的术语和试验方法标准》.pdf
  • ANSI IEEE 1246-2011 Guide for Temporary Protective Grounding Systems Used in Substations《变电所临时接地保护系统用指南》.pdf ANSI IEEE 1246-2011 Guide for Temporary Protective Grounding Systems Used in Substations《变电所临时接地保护系统用指南》.pdf
  • ANSI IEEE 1247-2005 Standard for Interrupter Switches for Alternating Current Rated Above 1000 V《额定电压大于1000伏的交流断路开关标准》.pdf ANSI IEEE 1247-2005 Standard for Interrupter Switches for Alternating Current Rated Above 1000 V《额定电压大于1000伏的交流断路开关标准》.pdf
  • ANSI IEEE 1250-2011 Guide for Identifying and Improving Voltage Quality in Power Systems《识别和改善电力系统电压质量指南》.pdf ANSI IEEE 1250-2011 Guide for Identifying and Improving Voltage Quality in Power Systems《识别和改善电力系统电压质量指南》.pdf
  • ANSI IEEE 1260-1996 Guide on the Prediction Measurement and Analysis of AM Broadcast Reradiation by Power Lines《电源线AM广播阻滞预测、测量和分析指南》.pdf ANSI IEEE 1260-1996 Guide on the Prediction Measurement and Analysis of AM Broadcast Reradiation by Power Lines《电源线AM广播阻滞预测、测量和分析指南》.pdf
  • ANSI IEEE 1278.3-1996 Recommended Practice for Distributed Interactive Simulation - Exercise Management and Feedback (IEEE Computer Society)《分布式人机对话模拟的推荐操作规程.练习管理和反馈》.pdf ANSI IEEE 1278.3-1996 Recommended Practice for Distributed Interactive Simulation - Exercise Management and Feedback (IEEE Computer Society)《分布式人机对话模拟的推荐操作规程.练习管理和反馈》.pdf
  • 相关搜索
    资源标签

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1