1、Designation: D 2609 02An American National StandardStandard Specification forPlastic Insert Fittings for Polyethylene (PE) Plastic Pipe1This standard is issued under the fixed designation D 2609; the number immediately following the designation indicates the year oforiginal adoption or, in the case

2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specif

3、ication covers plastic insert fittings for poly-ethylene (PE) plastic pipe. Included are requirements formaterials, workmanship, dimensions, and burst pressure.1.2 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (

4、excluding those in tables and figures) shallnot be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.4 The following safety hazards caveat pertains only tothe

5、 test methods portion, Section 8, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of re

6、gulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:D 256 Test Methods for Determining the Izod PendulumImpact Resistance of Plastics2D 618 Practice for Conditioning Plastics for Testing2D 638 Test Method for Tensile Properties of Plastics2D 648 Test Method for Deflection Te

7、mperature of PlasticsUnder Flexural Load in the Edgewise Position2D 789 Test Methods for Determination of Relative Viscos-ity and Moisture Content of Polyamide (PA)2D 1599 Test Method for Resistance to Short-Time Hydrau-lic Failure Pressure of Plastic Pipe, Tubing, and Fittings3D 1600 Terminology fo

8、r Abbreviated Terms Relating toPlastics2D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Compounds2D 2104 Specification for Polyethylene (PE) Plastic Pipe,Schedule 403D 2239 Specification for Polyethylene (PE) Plastic Pipe(SIDR-PR) Based o

9、n Controlled Inside Diameter3F 412 Terminology Relating to Plastic Piping Systems3F 1498 Specification for Taper Pipe Threads 60 for Ther-moplastic Pipe and Fittings32.2 NSF Standards:Standard No. 14 for Plastic Piping Components and RelatedMaterials4Standard No. 61 for Drinking Water System Compone

10、ntsHealth Effects43. Terminology3.1 Definitions are in accordance with Terminology F 412and abbreviations are in accordance with Terminology D 1600,unless otherwise specified.4. Classification4.1 This specification covers one class of fittings suitable foruse with PE plastic pipe that meet the requi

11、rements ofapplicable ASTM specifications. At present, these are Specifi-cations D 2104 and D 2239.5. Materials5.1 Types of PlasticsThe fittings shall be made from oneof the following plastics:5.1.1 Nylon plastics (NP) meeting the requirements ofeither Type I or Type II (except Grade 2A) in Test Meth

12、odsD 789.5.1.2 Propylene plastic (PP) with a minimum tensilestrength at yield of 24.0 MPa (3410 psi) when tested inaccordance with Test Method D 638 at a speed of 51 mm/min(2.0 in./min), an Izod impact resistance at 23C of at least 30J/m (0.6 ftlbf/in.) when tested in accordance with Method Aof Test

13、 Methods D 256, and a minimum deflection temperatureof 64C at 455 KPa stress when tested in accordance with TestMethod D 648.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.10 on Fittings.Current editio

14、n approved September 10, 2002. Published September 2002.Originally published as D 2609 67. Last previous edition D 2609 00.2Annual Book of ASTM Standards, Vol 08.01.3Annual Book of ASTM Standards, Vol 08.04.4Available from the National Sanitation Foundation, P.O. Box 1468, Ann Arbor,MI 48106.1Copyri

15、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.3 Poly(vinyl chloride) plastics (PVC) meeting the re-quirements of 12454-B, 12454-C, 11443-B, or 14333-D, inSpecification D 1784.5.2 Rework MaterialThe manufacturers shall use onlytheir ow

16、n clean rework fitting material and the fittings pro-duced shall meet all the requirements of this specification. Thetypes of materials specified in 5.1 shall not be mixed with oneanother.6. Requirements6.1 Dimensions and TolerancesThe dimensions and tol-erances shall be as shown in Tables 1-3 when

17、measured inaccordance with 8.4. The negative tolerance on all minimumdimensions is zero.6.1.1 AlignmentThe alignment of all openings of fittingsshall be within14in./ft.6.1.2 Fittings Not IllustratedAll fittings, whether illus-trated in Tables 1-3 or not, shall have insert ends in accordancewith Tabl

18、e 1 or threaded ends in accordance with Table 3. Forinsert ends, which have more than four barbs, the first fourbarbs, starting from the open end of the fitting connection, shallmeet all requirements of Table 1. The remaining barbs shallalso meet Table 1, with the exception that mold marks left asa

19、result of the manufacturing process, such as ejector pinmarks, are exempt from the “V” dimension requirement, andthe minimum requirement for “Z.” D, Zmax, and F apply in allcases. For designs where the entire fitting end is barbed, suchas “F” cannot be readily measured, “F” shall be calculated as(Z2

20、V)D/2.6.1.3 ThreadsFor all fittings having taper pipe threads,threads shall conform to Specification F 1498 and be gaged inaccordance with 8.6.6.2 Burst PressureThe minimum burst pressure for thefittings shall be as shown in Table 4, when determined inaccordance with 8.5.7. Workmanship, Finish, and

21、Appearance7.1 The fittings shall be homogeneous throughout and freeof cracks, holes, foreign inclusions, or other defects. Thefittings shall be as uniform as commercially practicable incolor, opacity, density, and other physical properties.8. Test Methods8.1 ConditioningCondition the specimens at 73

22、.4 6 3.6F(23 6 2C) and 50 6 5 % relative humidity for not less than 40TABLE 1 Dimensions of Insert End,Ain. (mm)NominalPipe SizeInsertLength, PBarbsDepth, VWallThickness,FInsideDiameter ofFitting, DLength,YOutside Diameter, ZBNumbermin min max min min min min min12 114 (31.8)34 (19.0) 0.665 (16.9) 0

23、.635 (16.1) 4 0.015 (0.4) 0.080 (2.0) 0.406 (10.3)34 114 (31.8)34 (19.0) 0.865 (22.0) 0.835 (21.2) 4 0.015 (0.4) 0.085 (2.2) 0.562 (14.3)1114 (31.8)34(19.0) 1.095 (27.8) 1.065 (27.0) 4 0.020 (0.5) 0.100 (2.5) 0.750 (19.0)114 114 (31.8)34 (19.0) 1.425 (36.2) 1.395 (35.4) 4 0.025 (0.6) 0.110 (2.8) 0.9

24、95 (25.3)112 112 (38.1)34 (19.0) 1.665 (42.3) 1.630 (41.4) 4 0.030 (0.8) 0.110 (2.8) 1.125 (28.6)2112 (38.1)34(19.0) 2.125 (54.0) 2.085 (53.0) 4 0.030 (0.8) 0.110 (2.8) 1.656 (42.1)212 2 (50.8) 1 (25.4) 2.520 (64.0) 2.487 (63.2) 4 0.030 (0.8) 0.120 (3.0) 2.062 (52.4)3218 (54.0) 118(28.6) 3.125 (79.4

25、) 3.086 (78.4) 4 0.030 (0.8) 0.125 (3.2) 2.600 (66.0)4 3 (76.2) 114 (31.8) 4.090 (103.9) 4.044 (102.7) 4 0.030 (0.8) 0.130 (3.3) 3.525 (89.5)AThe sketches and designs of fittings shown are illustrative only. The dimensions specified shall govern in all cases.BOutside diameter maximum and minimum app

26、ly to each individual measurement, not the average of the four (see 8.4).TABLE 2 DimensionsAof Insert Elbow and Tee, in. (mm)Nominal PipeSizeBLaying Length Tee and Elbow, min G12 0.344 (8.7)34 0.453 (11.5)1 0.625 (15.9)114 0.781 (19.8)112 0.875 (22.2)2 1.125 (28.6)212 1.625 (41.3)3 1.875 (47.6)4 2.4

27、38 (61.9)AThe sketches and designs of fittings shown are illustrative only.BFor dimensions not given in this table, see Table 1.D 2609 022h prior to test in accordance with Procedure A of PracticeD 618, for those tests where conditioning is required. In allcases of disagreement, the tolerances shall

28、 be 61.8F (61C)and 62 % relative humidity.8.2 Test ConditionsConduct the tests in the standardlaboratory atmosphere of 73.4 6 3.6F (23 6 2C) and 506 5 % relative humidity, unless otherwise specified in the testmethods or in this specification. In cases of disagreement, thetolerances shall be 61.8F (

29、1C) and 62 % relative humidity.8.3 SamplingA sample of the fittings sufficient to deter-mine conformance with this specification shall be taken atrandom.8.4 DimensionsFittings used to determine dimensionsshall be randomly selected. Measurements shall be made withmicrometers, calipers, gages, or othe

30、r devices accurate towithin 60.001 in. (60.025 mm). Determine the diameters bymaking measurements at four points spaced at approximately45 apart around the circumference.8.5 Burst PressureDetermine the minimum burst pressurewith at least three specimens in accordance with Test MethodD 1599. Join the

31、 fittings as insert fittings to the pipe sufficientlystrong and in such a manner that no failure shall occur in thefitting at least than the pressures given in Table 4. The time oftesting each assembly shall be between 60 and 70 s.8.6 ThreadsAll taper pipe threads shall be gaged inaccordance with Sp

32、ecification F 1498.9. Retest and Rejection9.1 If the results of any test(s) do not meet the requirementsof this specification, the tests(s) shall be conducted again onlyby agreement between the purchaser and seller. Under suchagreement, minimum requirements shall not be lowered,changed, or modified,

33、 nor shall specification limits be changed.If upon retest, failure occurs, the quantity of product repre-sented by the test(s) does not meet the requirements of thisspecification.10. Marking10.1 Fittings shall be marked with the following:10.1.1 Manufacturers name or trademark,10.1.2 Material design

34、ation: NP, PP, or PVC,10.1.3 Fittings intended for the transport of potable watershall include the seal or mark of the laboratory making theevaluation for this purpose, and10.1.4 Size.10.2 Markings or symbols shall be molded, hot-stamped, orapplied by printing methods.10.3 Where recessed marking is

35、used, care shall be taken tosee that in no case shall the marking cause cracks or reduce thewall thicknesses below the minimum specified.11. Quality Assurance11.1 When the product is marked with this designation, D2609, the manufacturer affirms that the product was manufac-tured, inspected, sampled,

36、 and tested in accordance with thisspecification and has been found to meet the requirements ofthis specification.12. Keywords12.1 barb; fittings; insert; plastic; polyethyleneTABLE 3 DimensionsAof Insert Adapters with Pipe Thread End,in. (mm)Nominal PipeSize,BInsertEnd and PipeThreadCLength of Thre

37、ad, minMale, S Female, T12 0.53 (13.5) 0.64 (16.2)34 0.55 (14.0) 0.65 (16.5)1 0.68 (17.3) 0.81 (20.6)114 0.71 (18.0) 0.85 (21.6)112 0.72 (18.3) 0.85 (21.6)2 0.76 (19.3) 0.90 (22.9)212 1.14 (28.9) 1.21 (30.7)3 1.20 (30.5) 1.30 (33.0)4 1.30 (33.0) 1.38 (35.0)AThe sketches and designs of fittings shown

38、 are illustrative only.BFor dimensions of insert ends, see Table 1.CFor threads on threaded end, see 6.1.3.TABLE 4 Burst Pressure Requirements for Water at 73.4F(23C) for Plastic Insert Fittings for PE Plastic PipeNominal PipeSize, in.Minimum Burst Strength, psi (MPa)NP, PP, and PVC Materials12 750

39、(5.7)34 630 (4.34)1 630 (4.34)114 630 (4.34)112 500 (3.45)2 500 (3.45)212 400 (2.76)3 400 (2.76)4 400 (2.76)6 250 (1.72)D 2609 023SUPPLEMENTARY REQUIREMENTSPOTABLE WATER REQUIREMENTThis requirement applies whenever a Regulatory Authority or user calls for the product to be usedto convey or to be in

40、contact with potable water.S1. Products intended for contact with potable water shallbe evaluated, tested, and certified for conformance with ANSI/NSF Standard No. 61 or the health effects portion of NSFStandard No. 14 by an acceptable certifying organization whenrequired by the regulatory authority

41、 having jurisdiction.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringemen

42、t of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or f

43、or additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views know

44、n to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 2609 024

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1