ASTM D3091-1972(2003) Standard Practice for Safe Filling of Low-Pressure Pressurized Products《低压压缩制品的安全罐装》.pdf

上传人:fuellot230 文档编号:514070 上传时间:2018-12-02 格式:PDF 页数:3 大小:30.41KB
下载 相关 举报
ASTM D3091-1972(2003) Standard Practice for Safe Filling of Low-Pressure Pressurized Products《低压压缩制品的安全罐装》.pdf_第1页
第1页 / 共3页
ASTM D3091-1972(2003) Standard Practice for Safe Filling of Low-Pressure Pressurized Products《低压压缩制品的安全罐装》.pdf_第2页
第2页 / 共3页
ASTM D3091-1972(2003) Standard Practice for Safe Filling of Low-Pressure Pressurized Products《低压压缩制品的安全罐装》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 3091 72 (Reapproved 2003)Standard Practice forSafe Filling of Low-Pressure Pressurized Products1This standard is issued under the fixed designation D 3091; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of

2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice covers the filling of

3、low-pressure pressur-ized products, either in the laboratory or in production.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter

4、mine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 2.2. General Safety Precautions2.1 Suitable storage should be supplied, both in the plantand laboratory, for toxic or flammable substances. Manufac-turers labels should be observed for t

5、oxicity or flammabilityinformation.2.2 Adequate fire extinguishers should be located at vitalpoints in the plant and laboratory. For small laboratory fires anextinguisher such as carbon dioxide is probably more suitable,since it is cleaner in operation.2.3 Suitable first aid equipment should be avai

6、lable in boththe plant and laboratory. Personnel should be instructed inproper first aid treatment to be used for different types ofinjuries that may occur.2.4 Safe practices should be encouraged by lectures andconstant reminders, such as posters, on the value of safetyprocedures.2.5 New operations

7、should be inspected closely for anypossible hazards, and necessary means should be devised toguard against such hazards.3. Laboratory Research and Experimental Work3.1 Storage of Propellants and Chemicals:3.1.1 PropellantsCylinders should be stored in cool, dry,accessible places. Care should be exer

8、cised in handling cylin-ders so that they do not drop or strike each other violently.When cylinders are tapped, all connectors should be leak-free.3.1.2 ChemicalsSuitable storage for flammable chemicalsand concentrates should be available. Any glass containersshould be handled with care to avoid bre

9、akage.3.2 Handling Propellants and Concentrates:3.2.1 PropellantsLaboratory personnel should be care-fully instructed in preventing burns and freezing when han-dling propellants with low boiling points. Precautions shouldbe taken for the possible accumulation of propellants to a pointwhere the norma

10、l oxygen content is decreased. Adequate ventsshould be supplied. When venting the propellants from pres-sure burets or cold filling lines, precautions should be taken toprevent over accumulations of propellant vapors, and tominimize flammability hazards.3.2.2 ConcentratesProper ventilation should be

11、 providedfor the handling of highly toxic liquids. Manufacturers in-structions should be observed for toxicity information concern-ing the raw materials used. Personnel should be instructed notto smoke or have any burners working in the vicinity of the useof flammable liquids.3.3 Handling of Sealing

12、 Machinery:3.3.1 All laboratory machinery, such as crimpers and seam-ers, should have adequate protection at those portions whereaccidents may occur. For example, all moving belts on seamersshould have guards or protective shields, or a device should beinstalled on crimpers to eliminate the possibil

13、ity of gettinghands caught between the crimping head and the can.3.3.2 When sealing valves onto glass containers, careshould be taken so that the machinery does not damage thebottle, thereby causing possible future hazards when the bottleand contents are examined at elevated temperatures. All crimps

14、and seams should be carefully inspected before the units arebrought to higher temperatures, thereby minimizing futureaccidents due to defective containers.3.3.3 All crimping of both glass and metal containers shouldbe measured in accordance with industry standards as to depth,diameter (in the case o

15、f cans), and depth and run-out (in thecase of glass), to assure adequacy of the crimp prior to theinsertion of the unit in a hot-water bath or high-temperaturestorage program.1This practice is under the jurisdiction of ASTM Committee D10 on Packagingand is the direct responsibility of Subcommittee D

16、10.33 on Mechanical Dispensers.This practice was originally developed by the Chemical Specialties ManufacturersAssociation.Current edition approved July 28, 1972. Published November 1972.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United State

17、s.3.4 Handling of Containers:3.4.1 All aerosol containers can be hazardous in laboratorywork, regardless of whether the containers are of plain glass,safety-coated glass, or metal. The following precautions shouldbe observed:3.4.1.1 Guard against overfills. When using a new type ofcontainer, determi

18、ne what is a safe fill before packing it.3.4.1.2 Guard against defective containers. Inspect all glasscontainers before use. Inspect all can seams for visible flaws.Take care not to damage the containers during the pack, as suchdefects can cause serious accidents later on in the tests. Inspectand di

19、scard empty containers for defects such as dirt and rust,to prevent their use for samples and subsequent stabilityprograms.3.4.1.3 When examining containers in a hot-water tank,provide adequate protection such as safety shields.3.4.1.4 Always wear protective face shields when workingwith any contain

20、er under pressure.3.4.1.5 Always handle glassware under pressure carefully,regardless of the pressure. All glassware under pressure shouldbe covered with a protective screen or coating.3.4.1.6 Guard against excessive pressure in all containers.3.4.1.7 Check storage oven mechanisms periodically topre

21、vent the possibility of overruns in temperature that maycause explosions with the containers under heat storage tests.Appropriate types of electrical equipment should be utilizedwhen the oven is used for the storage of products containingflammable solvents or vapors. The ovens should be equippedwith

22、 adequate ventilation to prevent the build-up of vapors dueto leakage.3.4.1.8 Perform all spray testing of valves in an adequatelyvented hood.3.4.1.9 When conducting open- and closed-drum tests,place the drum in a well-vented atmosphere, such as outdoorsor inserted in a hood, or both, to adequately

23、vent the contentsof the drum at the completion of the test. The fumes from suchtests can be toxic, and should be handled accordingly.4. Commercial Refrigeration Filling4.1 Handling of Propellant:4.1.1 Safe methods for unloading propellant cylinders are asfollows:4.1.1.1 If the cylinders are shipped

24、by truck, it is advisableto build a platform that will be level with the tailgate of thetruck and the building floor. A fork lift can then go into thetruck and not have to raise its platform more than 6 in. (152mm) to unload the cylinders. Provisions should be made so thatthe cylinders can not slip

25、off the fork lift.4.1.1.2 When using a hoist to lift the cylinders off of trucksor railroad cars, employ the proper equipment. The hoist,chains, hooks, and runner beams should be selected to handlethe mass of the cylinders plus a safety factor. The equipmentshould be periodically checked for flaws,

26、and personnel shouldbe instructed in its proper use. It should be impressed uponthose unloading the cylinders that all grabbing hooks andchains are to be secured before unloading.4.1.2 Safe methods for storing and tapping cylinders are asfollows:4.1.2.1 Cylinders are protected from excessive pressur

27、esdue to heat by fusible plugs in the container and valves thatmelt at 157F (69C). Never permit live steam or direct flameto be applied to any part of the container.4.1.2.2 Store the containers in a cool, dry, accessible place,keeping them away from salt or other corrosive chemicals orfumes as rusti

28、ng will damage the containers and cause thevalve hoods to stick. The containers must not be dropped orpermitted to strike each other violently. To avoid this, securelyblock the containers.4.1.2.3 Do not tamper with the safety devices in the valve orcontainer.4.1.2.4 Replace the brass on plastic prot

29、ective caps on thevalves of the cylinders to prevent dirt from entering the valvesand damage to the threads on the valve connections. Secure thevalve hoods after the container has been emptied.4.1.2.5 If heat must be applied to propellant containersproceed using one of the following: either (1) Appl

30、y hot airheat from steam coils, steam space heaters, or electric resis-tance heaters but, do not immerse the container in a hot waterbath or under any circumstances apply a blow torch or openflame, or (2) Heat by the use of infrared lamps, using aclamp-on thermocouple on the container surface to con

31、trol thelamps. An additional precaution against overheating is havinga cut-out switch on the lamp circuit that is actuated by thepressure of the propellant by means of a direct connection tothe container outlet line during the heating period.4.1.2.6 The excessive accumulation of propellant vapors at

32、various points in the plant is another factor to be considered inthe handling of propellants. Although the vapors themselvesare relatively nontoxic, the tendency is for a decrease in theoxygen content of the atmosphere. Excessive vapors willprobably accumulate on the floor around the filling line, d

33、ue tothe high vapor density of the propellants. If care is notexercised, the accumulation of propellant vapors may exceed atolerable amount. The normal oxygen content of the air is21 %. When the oxygen content is less than 16 %, life cannotbe supported. A possible solution to this would be the insta

34、l-lation of an exhaust system along the floor.4.2 Handling of Concentrates:4.2.1 If the concentrate ingredients are blended at the fillingplant, precautions should be taken when handling and mixing.If the ingredients are toxic, adequate ventilation should beprovided (for example, an exhaust system).

35、 Regardless of whatthe ingredients are, mixing should be done in an enclosed tankto prevent splattering of the material.4.2.2 Concentrate tanks should be equipped with safetyvalves, especially if the concentrate is highly volatile. Safetyvalves set to open at a designated pressure, relative to theco

36、ncentrate being used, will prevent excessive build-up of thepressure.4.2.3 Appropriate precautions should be taken if the con-centrate is flammable or toxic.4.3 Can UnscramblerSafety devices should be installed ifthe possibility of injury to the operator setting the cans onto theunscrambler exists.

37、An automatic shutoff should be installed inthe case of jam-ups.4.4 Point of Filling:D 3091 72 (2003)24.4.1 Precautions should be taken to prevent the splatteringof concentrates and propellants by the installation of aclosed-in area with a clear plastic or glass shield in front of theoperators.4.4.2

38、Exhaust hoods should be installed over the point offilling to evacuate harmful vapors.4.5 Filling Point to Valve Crimper:4.5.1 Liquid FillOverfilled cans are dangerous and shouldbe avoided. The following checks should be installed:4.5.1.1 Constant checking of metering devices on fillingunits, and4.5

39、.1.2 Some type of check for the liquid contents of thecans. The checking of can mass (probably the most widely usedsystem for checking can contents) should be in use if noautomatic equipment2is available. These checks should bemade as often as possible.4.5.2 Dangerous Vapor ProtectionAn exhaust hood

40、should be installed to eliminate dangerous vapors.4.5.3 Valve CrimperConstant monitoring of the valve-crimping phase should be maintained to ensure adequacy of thecrimp depth and diameter measurements. Any indication thatthe measurements are out of specification should result in theimmediate shuttin

41、g down of the line to correct and preventimproperly crimped cans from passing into the hot-water bath.4.6 Hot-Water TanksTake the following precautions atthis, the most important point of the aerosol filling operation:4.6.1 Shields should be installed over the hot-water tanks toprovide protection ag

42、ainst units that may explode, or thepersonnel should wear face shields. For added protection, theoperators should be supplied with safety glasses.4.6.2 A dependable thermostatic control should be installedto keep the bath temperature at the desired level. The heatingapparatus, as well as the heat co

43、ntrol apparatus, should beperiodically checked.4.7 Spray TestingAll spray testing should be conducted inan exhaust hood. The operators should be instructed to deter-mine the direction of the spray from the valve, depending onthe valve being used, to prevent spraying on themselves.4.8 Storage of Fini

44、shed Units:4.8.1 The finished units should be stored in a cool, dryplace, if they are to be retained at the filling plant for any lengthof time before shipment.4.8.2 Suitable cartons and stacking methods should beemployed to prevent unnecessary damage to the units.5. Commercial Pressure Filling5.1 S

45、afety shields should be installed in front of the filler tosafeguard against the possibility of container explosion.5.2 Safety guards should be installed on all exposed parts ofthe machinery where it is possible for an operator to be injured.5.3 A close check should be kept on all metering devices t

46、oprevent the possibility of dangerous overfills.5.4 The units should be checked for overfills after the fillingby either an automatic checker or the weighing of the cans.5.5 If flammable propellants are handled, the followingprecautions should be taken:5.5.1 Constant monitoring of the vapor concentr

47、ationshould be maintained by an automatic gas analyzer. Thesecontrols should be part of a system that would allow theimmediate shut-off of the propellant flow should the vaporconcentration approach a critical point (that is, a maximum of25 % of the low explosive limit). Explosion-proof equipment ism

48、andatory.5.5.2 All personnel operating in areas utilizing flammablepropellants should take the following precautions:5.5.2.1 Non-sparking tools should be used. The tools shouldbe made of metals such as aluminum or beryllium copper.5.5.2.2 Rubber-soled shoes should be worn.5.5.3 The area surrounding

49、the propellant handling shouldbe designed for spark-free control.5.6 All pressure lines handling high-pressure liquids shouldcontain pressure switches for automatic relief of high pressuresdeveloped during the pumping operations.5.7 All other safety measures concerning the handling of thepropellant and concentrate, the can unscrambler, the point offilling, the valve crimper, and after filling procedures should bein accordance with Section 4.6. Keywords6.1 aerosol containers; aerosol products filling; low pressureaerosol packaging; aerosol containers; pressure filling; prope

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1