ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf

上传人:deputyduring120 文档编号:514219 上传时间:2018-12-02 格式:PDF 页数:6 大小:143.90KB
下载 相关 举报
ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf_第1页
第1页 / 共6页
ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf_第2页
第2页 / 共6页
ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf_第3页
第3页 / 共6页
ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf_第4页
第4页 / 共6页
ASTM D3173 D3173M-2017a Standard Test Method for Moisture in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中灰分的标准试验方法》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D3173/D3173M 17D3173/D3173M 17aStandard Test Method forMoisture in the Analysis Sample of Coal and Coke1This standard is issued under the fixed designation D3173/D3173M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision,

2、the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*Scope1.1 This test method covers the determination of moisture in the analysis sample of coal or coke. It is

3、used for calculating otheranalytical results to a dry basis. When used in conjunction with the air drying loss as determined in accordance with Method D2013or Practice D346, each analytical result can be calculated to an as-received basis:1.2 The values stated in either SI units or inch-pound units

4、are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address

5、 all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard was developed in accordance wi

6、th internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:

7、2D121 Terminology of Coal and CokeD346 Practice for Collection and Preparation of Coke Samples for Laboratory AnalysisD2013 Practice for Preparing Coal Samples for AnalysisD3180 Practice for Calculating Coal and Coke Analyses from As-Determined to Different BasesD3302 Test Method for Total Moisture

8、in Coal3. Terminology3.1 DefinitionsFor additional definitions of terms used in this test method, refer to Terminology D121.4. Summary of Test Method4.1 Moisture is determined by establishing the loss in weight of the sample when heated under rigidly controlled conditions oftemperature, time and atm

9、osphere, sample weight, and equipment specifications.5. Significance and Use5.1 Moisture as determined by this test method is used for calculating other analytical results to a moisture free basis usingprocedures in Practice D3180. Moisture percent determined by this test method may be used in conju

10、nction with the air-drymoisture loss determined in Method D2013 and Test Method D3302 to determine total moisture in coal. Total moisture is used forcalculating other analytical results to “as received” basis using Practice D3180. Moisture, ash, volatile matter, and fixed carbonpercents constitute t

11、he proximate analysis of coal and coke.6. Analysis Sample6.1 The analysis sample is that sample which has been pulverized to pass 250-m (No. 60) sieve as prepared in accordance withPractice D346 or Method D2013.1 This test method is under the jurisdiction of ASTM Committee D05 on Coal and Coke and i

12、s the direct responsibility of Subcommittee D05.21 on Methods of Analysis.Current edition approved Feb. 1, 2017Aug. 1, 2017. Published February 2017August 2017. Originally approved in 1973. Last previous edition approved 2011 in 2017 asD3173 11.D3173/D3173M 17. DOI: 10.1520/D3173_D3173M-17.10.1520/D

13、3173_D3173M-17a.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is

14、intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the c

15、urrent versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17. Apparatus7.1 Drying Oven,

16、 for coal samples:7.1.1 For determining the moisture of coal, the oven shall be so constructed as to have a uniform temperature in all parts, havea minimum of air space, and be capable of temperature regulation between the limits of 104 and 110C. It may be of the formshown in Fig. 1. Provision shall

17、 be made for renewing the preheated air in the oven at the rate of two to four times a minute, withthe air dried as defined in 8.1.7.1.2 In the oven shown in Fig. 1, the door should contain a hole of approximately 3.2 mm 18 in. in diameter near the bottomto permit a free flow of air through the oven

18、 space.7.2 Drying Oven, for coke samples. For determining the moisture of coke, an ordinary drying oven with openings for naturalair circulation and capable of temperature regulation between limits of 104 and 110C may be used.7.3 Capsules, with covers.Aconvenient form, which allows the ash determina

19、tion to be made on the same sample, is a porcelaincapsule, 22 mm 78 in. in depth and 44 mm 134 in. in diameter, or a fused silica capsule of similar shape. These capsules shallbe used with a well-fitting flat aluminum cover, illustrated in Fig. 2. Platinum crucibles or glass capsules with ground-gla

20、ss capsmay also be used. They should be as shallow as possible, consistent with convenient handling.7.4 Balance, sensitive to 0.1 mg.8. Reagents8.1 Dry AirAir used to purge the drying oven should be dried to a moisture content of 1.9 mg/L or less. (Dew point 10Cor less.) Any desiccant or drying meth

21、od capable of achieving this degree of dryness is suitable.NOTE 1Values in parentheses ( ) are literature values for the residual amount of moisture in air at equilibrium with these desiccants. (Warning:Sulfuric acid is corrosive and can cause severe damage to eyes, skin, and clothing. Magnesium per

22、chlorate is a strong oxidant and can react violentlywith organic materials.): Anhydrous Calcium Sulfate (0.004 mg/L), Silica Gel,Magnesium Perchlorate (0.0005 mg/L), Sulfuric Acid, Concentrated (0.003mg/L).8.2 DesiccantsMaterials suitable for use in the desiccator may be chosen from the following:An

23、y desiccant or drying methodcapable of achieving this degree of dryness as defined in 8.1 is suitable.8.2.1 Anhydrous Calcium Sulfate (0.004 mg/L).8.2.2 Silica Gel.8.2.3 Magnesium Perchlorate (0.0005 mg/L).8.2.4 Sulfuric Acid, Concentrated (0.003 mg/L).8.2.1 The desiccant must be kept fresh enough t

24、o assure that the air in the desiccator is dry as defined in 8.1. Values inparentheses ( ) are literature values for the residual amount of moisture in air at equilibrium with these desiccants. (Warning:Sulfuric acid is corrosive and can cause severe damage to eyes, skin, and clothing. Magnesium per

25、chlorate is a strong oxidant andcan react violently with organic materials.)NOTE 1Details in U.S. Bureau of Mines Bulletin No. 492, 1951, p 6.FIG. 1 Moisture OvenD3173/D3173M 17a29. Procedure for Sample Passing a 250-m (No. 60) Sieve9.1 Heat the empty capsules under the conditions at which the sampl

26、e is to be dried, place the stopper or cover on the capsule,cool over a desiccant for 15 to 30 min, and weigh. Dip out with a spoon or spatula from the sample bottle approximately 1 g ofthe sample. Put this quickly into the capsule, close, and weigh at once to the nearest 60.1 mg.9.2 An alternative

27、procedure for weighing the sample (more subject to error) is as follows: After transferring an amount of thesample slightly in excess of 1 g, bring to exactly 1 g in weight (60.5 mg) by quickly removing the excess weight of the samplewith a spatula. The utmost dispatch must be used to minimize the e

28、xposure of the sample until the weight is determined.9.3 After removing the covers, quickly place the capsules in a preheated oven (at 104 to 110C) through which passes a currentof dry air. (The current of dry air is not necessary for coke.) Close the oven at once and heat for 1 h. Open the oven, co

29、ver thecapsules quickly, cool in a desiccator over desiccant, and weigh as soon as the capsules have reached room temperature.9.4 Use the percentage of moisture in the sample passing a 250-m (No. 60) sieve to calculate the results of the other analysesto a dry basis.10. Calculations10.1 Calculate th

30、e percent moisture in the analysis sample as follows:Moisture in analysis sample,%5A 2B!/A# 3100 (1)where:A = grams of sample used andB = grams of sample after heating.11. Report11.1 Report the following information:11.1.1 Moisture in the analysis sample, %, to the nearest 0.01 percentage point.11.

31、Precision and Bias311.1 PrecisionThe precision of this method for the determination of moisture in the analysis sample of coal and coke is shownin Table 1 and Table A1.2. The precision characterized by repeatability (Sr,r) and reproducibility (SR,R) is described in Table A1.1in Annex A1.11.1.1 Repea

32、tability Limit (r)The value below which the absolute difference between two test results calculated to separateconsecutive test determinations, carried out on the same sample in the same laboratory, by the same operator, using the sameapparatus on samples taken at random from a single quantity of ho

33、mogenous material, may be expected to occur with a probabilityof approximately 95%.3 An interlaboratory study, designed consistent with Practice E691, was conducted in 1995. Twelve labs participated. Supporting data have been filed atASTM InternationalHeadquarters and may be obtained by requesting R

34、esearch Report RR:D05-1020. In addition, information for coke was calculated per Practice E 691 using 48 sets of datafor 24 coke samples from a commercially available inter-laboratory proficiency test program. The cokes used in this study included furnace coke, foundry coke and cokebreeze. Details a

35、nd supporting information are given in Research Report RR:D05-1039 .FIG. 2 Capsule for Use in Determining MoistureTABLE 1 PrecisionRange RepeatabilityLimit(r)ReproducibilityLimit(R)Coal 1.0 21.9 % 0.09 + 0.01xA 0.23 + 0.02xACoke 0.181.87% 0.08 0.24AWhere x is the average of two single test results.D

36、3173/D3173M 17a311.1.2 Reproducibility Limit (R)The value below which the absolute difference between two test results, carried out indifferent laboratories, using samples taken at random from a single quantity of material that is as nearly homogenous as possible,may be expected to occur with a prob

37、ability of approximately 95%.11.2 BiasCertified Reference Materials are not available for the determination of bias by this test method.12. Report12.1 Report the following information:12.1.1 Moisture in the analysis sample, %, to the nearest 0.01 percentage point.ANNEX(Mandatory Information)A1. PREC

38、ISION STATISTICSA1.1 The precision of this test method, characterized by repeatability (Sr,r) and reproducibility (SR,R) has been determined for thefollowing materials as listed in Table A1.1 and Table A1.2.A1.2 Repeatability Standard Deviation (Sr)The standardTABLE A1.1 Repeatability (Sr,r) and Rep

39、roducibility (SR,R)Parameters Used for Calculation of Precision Statement for CoalSamplesNOTE 1The R-Squared statistic for both the repeatability (r) andreproducibility (R) indicates that the model as fitted explains 62% of thevariability in the two variables.Material Average Sr SR r R91-2Ivb 0.9683

40、 0.0479 0.0853 0.1341 0.238891-1 hvAb 1.5689 0.0569 0.1387 0.1593 0.388491-5 hvAb 3.1178 0.0559 0.0977 0.1564 0.273689-4 hvCb 5.4428 0.0601 0.1408 0.1682 0.394391-4 hvCb 9.6392 0.0636 0.1004 0.1781 0.281190-1 subB 11.9 0.1252 0.2193 0.3505 0.61489-7 subA 12.4556 0.0798 0.1188 0.2234 0.332691-6 subA

41、15.1753 0.0577 0.1737 0.1615 0.486589-6 subC 21.9461 0.1949 0.2843 0.5456 0.796D3173/D3173M 17a4deviation of test results obtained under repeatability conditions.A1.3 Reproducibility Standard Deviation (SR)The standard deviation of test results obtained under reproducibility conditions.TABLE A1.2 Re

42、peatability (Sr,r) and Reproducibility (SR,R)Parameters Used for Calculation of Precision Statement for CokeSamplesMaterial Average Sr SR r RCK980108 - Furnace 0.19 0.04 0.08 0.12 0.22CK980312 - Furnace 0.30 0.05 0.15 0.13 0.41CK980716 - Foundry 0.27 0.03 0.10 0.08 0.29CKReference2 - Furnace 0.18 0.

43、03 0.11 0.09 0.30CKNIST01 - Foundry 0.57 0.04 0.09 0.13 0.24CKNIST02 - Furnace 0.30 0.03 0.06 0.09 0.18CK0303 - Foundry 0.75 0.03 0.06 0.09 0.16CK9903 - Foundry 0.50 0.04 0.10 0.10 0.29CK9904 - Furnace 0.65 0.03 0.10 0.08 0.27CK0001 - Furnace 0.44 0.03 0.07 0.09 0.21CK0401 - Furnace 0.58 0.03 0.10 0

44、.07 0.30CK0002 - Breeze 0.46 0.02 0.15 0.04 0.42CK0302 - Breeze 0.55 0.04 0.05 0.10 0.13CK0003 - Foundry 0.31 0.02 0.08 0.07 0.24CK0101 - Furnace 0.19 0.02 0.08 0.04 0.23CK0504 - Furnace 0.28 0.04 0.08 0.10 0.23CK0701 - Furnace 0.29 0.02 0.08 0.06 0.24CK0102 - Furnace 0.33 0.04 0.10 0.10 0.29CK0301

45、- Furnace 0.34 0.01 0.08 0.04 0.23CK0404 - Furnace 0.50 0.02 0.07 0.06 0.21CK0103 - Furnace 1.04 0.03 0.30 0.07 0.84CK0304 - Furnace 1.49 0.02 0.10 0.06 0.27CK0601 - Furnace 1.54 0.03 0.05 0.08 0.14CK0903 - Furnace 1.87 0.07 0.08 0.18 0.23CK0104 - Furnace 0.20 0.01 0.08 0.04 0.23CK0503 - Furnace 0.3

46、5 0.02 0.06 0.06 0.17CK0201 - Furnace 0.51 0.03 0.08 0.08 0.22CK0501 - Furnace 0.59 0.03 0.13 0.08 0.36CK0802 - Furnace 0.72 0.02 0.08 0.05 0.23CK0904 - Furnace 0.77 0.03 0.08 0.08 0.24CK0202 - Furnace 0.35 0.02 0.13 0.06 0.36CK0502 - Furnace 0.46 0.02 0.11 0.06 0.32CK0603 - Furnace 0.53 0.04 0.08 0

47、.10 0.23CK0203 - Furnace 0.21 0.02 0.08 0.05 0.24CK0403 - Furnace 0.24 0.02 0.07 0.06 0.20CK0604 - Furnace 0.23 0.03 0.09 0.07 0.26CK0801 - Furnace 0.18 0.02 0.05 0.06 0.14CK0204 - Breeze 0.60 0.04 0.19 0.10 0.54CK0402 - Breeze 0.72 0.04 0.10 0.12 0.27CK0602 - Breeze 0.72 0.03 0.14 0.07 0.40CK0704 -

48、 Breeze 0.81 0.02 0.08 0.05 0.22CK0702 - Furnace 0.64 0.06 0.24 0.18 0.67CK0902 - Furnace 0.91 0.04 0.18 0.11 0.50CK0703 - Coke 1.68 0.04 0.11 0.11 0.30CK0803 - Furnace 0.43 0.02 0.10 0.06 0.28CK0804 - Furnace 0.44 0.02 0.06 0.06 0.17CK0901 - Coke 0.27 0.03 0.06 0.09 0.18CK1001 - Furnace 0.29 0.03 0

49、.11 0.09 0.30D3173/D3173M 17a5SUMMARY OF CHANGESCommittee D05 has identified the location of selected changes to this standard since the last issue (D3173-11)that may impact the use of this standard.(1) Added sections 3 and 11.(2) Note 3 of subsection 12.2 was deleted.(3) Section A1.1 was revised.(4) Designation was corrected to D3173/D3173M.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that d

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1