ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf

上传人:tireattitude366 文档编号:515726 上传时间:2018-12-02 格式:PDF 页数:6 大小:196.98KB
下载 相关 举报
ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf_第1页
第1页 / 共6页
ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf_第2页
第2页 / 共6页
ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf_第3页
第3页 / 共6页
ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf_第4页
第4页 / 共6页
ASTM D3886-1999(2015) Standard Test Method for Abrasion Resistance of Textile Fabrics (Inflated Diaphragm Apparatus)《纺织物耐磨性的标准试验方法 (膨胀膜法)》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D3886 99 (Reapproved 2015)Standard Test Method forAbrasion Resistance of Textile Fabrics (Inflated DiaphragmApparatus)1This standard is issued under the fixed designation D3886; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re

2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method2covers the determination of theresistance to abrasion of woven and knitted textil

3、e fabrics, bothconditioned and wet, using the inflated diaphragm tester. Thisprocedure is not applicable to floor coverings.NOTE 1Other procedures for measuring the abrasion resistance oftextile fabrics are given in Test Methods D3884, D3885, D1175 andAATCC Test Method 93.1.2 The values stated in SI

4、 units are to be regarded asstandard; the values in English units are provided as informa-tion only and are not exact equivalents.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis

5、h appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D123 Terminology Relating to TextilesD1175 Method of Test for Abrasion Resistance of TextileFabrics (Oscillatory Cylinder and Uniform Abrasion

6、);Replaced by D 4157, D 4158 (Withdrawn 1981)4D1776 Practice for Conditioning and Testing TextilesD2904 Practice for Interlaboratory Testing of a Textile TestMethod that Produces Normally Distributed Data (With-drawn 2008)4D2906 Practice for Statements on Precision and Bias forTextiles (Withdrawn 20

7、08)4D3884 Guide for Abrasion Resistance of Textile Fabrics(Rotary Platform, Double-Head Method)D3885 Test Method for Abrasion Resistance of TextileFabrics (Flexing and Abrasion Method)D4850 Terminology Relating to Fabrics and Fabric TestMethods2.2 AATCC Standard:Test Method 93 Abrasion Resistance of

8、 Fabrics: AcceleratorMethod53. Terminology3.1 For all terminology related to D13.60, Fabric TestMethods, Specific, see Terminology D4850.3.2 The following term is relevant to this standard: abrasion.3.3 For definitions of all other textile terms see TerminologyD123.4. Summary of Test Method4.1 A spe

9、cimen is abraded by rubbing either unidirection-ally or multidirectionally against an abradant having specifiedsurface characteristics. A specimen is held in a fixed positionand supported by an inflated rubber diaphragm which is heldunder constant pressure. A specimen is abraded by rubbingeither uni

10、directionally or multidirectionally against an abradanthaving specified surface characteristics. The resistance toabrasion is determined using Option 1, the number of cycles towear a hole in the specimen, or Option 2, visual assessment ofthe specimen surface after a specified number of cycles.5. Sig

11、nificance and Use5.1 The measurement of the resistance to abrasion of textileand other materials is very complex. The resistance to abrasionis affected by many factors, such as the inherent mechanicalproperties of the fibers; the dimensions of the fibers; thestructure of the yarns; the construction

12、of the fabrics; and thetype, kind, and amount of finishing material added to the fibers,yarns, or fabric.1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.60 on Fabric Test Methods,Specific.Current edition approved July

13、1, 2015. Published September 2015. Originallyapproved in 1980. Last previous edition approved in 2011 as D3886 99(2011)1.DOI: 10.1520/D3886-99R15.2This test method is based upon the development described by R. G. Stoll, in“Improved Multipurpose Abrasion Test and Its Application for the Wear Resistan

14、ceof Textiles,” Textile Research Journal , July 1949, p. 394.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.

15、4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American Association of Textile Chemists and Colorists, P.O.Box 12215, Research Triangle Park, NC 27709.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29

16、59. United States15.2 The resistance to abrasion is also greatly affected by theconditions of the tests, such as the nature of abradant, variableaction of the abradant over the area of specimen abraded, thetension of the specimen, the pressure between the specimenand abradant, and the dimensional ch

17、anges in the specimens.5.3 Abrasion tests are all subject to variation due to changesin the abradant during specific tests. The abradant mustaccordingly be discarded at frequent intervals or checkedperiodically against a standard. With disposable abradants, theabradant is used only once or discarded

18、 after limited use. Withpermanent abradants that use hardened metal or equivalentsurfaces, it is assumed that the abradant will not changeappreciably in a specific series of tests. Similar abradants usedin different laboratories will not change at the same rate, due todifferences in usage. Permanent

19、 abradants may also change dueto pick up of finishing or other material from test fabrics andmust accordingly be cleaned at frequent intervals. The mea-surement of the relative amount of abrasion may also beaffected by the method of evaluation and may be influenced bythe judgment of the operator.5.4

20、 The resistance of textile materials to abrasion as mea-sured on a testing machine in the laboratory is generally onlyone of several factors contributing to wear performance ordurability as experienced in the actual use of the material.While “abrasion resistance” (often stated in terms of thenumber

21、of cycles on a specified machine, using a specifiedtechnique to produce a specified degree or amount of abrasion)and “durability” (defined as the ability to withstand deteriora-tion or wearing out in use, including the effects of abrasion) arefrequently related, the relationship varies with differen

22、t enduses, and different factors may be necessary in any calculationof predicted durability from specific abrasion data. Laboratorytests may be reliable as an indication of relative end-useperformance in cases where the difference in abrasion resis-tance of various materials is large, but they shoul

23、d not be reliedupon where differences in laboratory test findings are small. Ingeneral, they should not be relied upon for prediction of actualwear-life in specific end uses unless there are data showing thespecific relationship between laboratory abrasion tests andactual wear in the intended end-us

24、e.5.5 These general observations apply to all types of fabrics,including woven, nonwoven, and knit apparel fabrics, house-hold fabrics, industrial fabrics, and floor coverings. It is notsurprising, therefore, to find that there are many different typesof abrasion testing machines, abradants, testing

25、 conditions,testing procedures, methods of evaluation of abrasion resis-tance and interpretation of results.5.6 All the test methods and instruments so far developedfor measuring abrasion resistance may show a high degree ofvariability in results obtained by different operators and indifferent labor

26、atories; however, they represent the test methodsnow most widely in use.5.7 Because there is a definite need for measuring therelative resistance to abrasion, standardized test methods areneeded and useful and may clarify the problem and lessen theconfusion.5.8 Because of the conditions mentioned ab

27、ove, techniciansfrequently fail to get good agreement between results obtainedon the same type of testing instrument both within and betweenlaboratories, and the precision of these test methods is uncer-tain.5.9 Test Method D3886 is not recommended for acceptancetesting of commercial shipment becaus

28、e of the poor between-laboratory precision.5.9.1 In cases of a dispute arising from differences inreported test results when using this test method for acceptancetesting of commercial shipments, the purchaser and the sup-plier should conduct comparative tests to determine if there isa statistical bi

29、as between their laboratories. Competent statis-tical assistance is recommended for the investigation of bias.As a minimum, the two parties should take a group of testspecimens which are as homogeneous as possible and whichare from a lot of material of the type in question. The testspecimens should

30、then be randomly assigned in equal numbersto each laboratory for testing. The average results from the twolaboratories should be compared using appropriate statisticalanalysis for unpaired data and an acceptable probability levelchosen by the two parties before the testing begins. If a bias isfound,

31、 either its cause must be found and corrected or thepurchaser and the supplier must agree to interpret future testresults in the light of the known bias.6. Apparatus6.1 Inflated Diaphragm Abrasion Tester6, shown in Fig. 1and Fig. 2 with the following essential parts:6.1.1 Surface Abrasion HeadThe sp

32、ecimen is mounted ina circular clamp over a rubber diaphragm by means of aclamping ring and a tightening collar. The circular opening ofthe clamping ring is 94.0 6 1.3 mm (3.70 6 0.05 in.) indiameter and that of the collar 95.3 mm (3.75 in.) or more. Theheight from the surface of the clamped-in spec

33、imen to theupper edge of the tightening collar shall not exceed 9.5 mm (38in.). The clamping area of the body of the clamp and the ringshould have gripping surfaces to prevent slipping of thespecimen and leakage of air pressure during the test. Meansshould be provided for supplying air pressure to t

34、he body of theclamp so that the pressure under the diaphragm can becontrolled between 0 and 41 kPa (0 and 6 psi) with an accuracyof 65 % of range.6.1.2 DiaphragmThe rubber diaphragm should be 1.40 60.25 mm (0.055 6 0.010 in.) in thickness. A metallic contactpin 3.2 mm (18 in.) in diameter is sealed

35、into the center of thediaphragm flush with the diaphragm surface. Provision shouldbe made for a flexible electrical connection from this contactpin to the ground of the machine. The strain distribution on thediaphragm must be uniform so that when inflated without thespecimen, it assumes the shape of

36、 a section of a sphere.Pressure can be controlled from 0 to 41 kPa (0 to 6 psi).6.1.3 Driving MechanismThe design of the drivingmechanism is such that the circular clamp makes a reciprocalmotion of 115 6 15 double strokes per minute of 25-mm(1-in.) stroke length. Provision shall be made for rotation

37、 of the6Apparatus is available commercially.D3886 99 (2015)2clamp in addition to the reciprocating motion so that onerevolution can be completed in 100 6 10 double strokes.6.1.4 Balance Head and Abradant Plate The abradant ismounted upon a plate, which is rigidly supported by adouble-lever assembly

38、to provide for free movement in adirection perpendicular to the plane of the reciprocatingspecimen clamp. The abradant plate assembly should be wellbalanced to maintain a vertical pressure equivalent to a mass of0 to 2.2 kg (0 to 5 lb) by means of dead weights. Provisionshould be made to mount diffe

39、rent abradants such as abrasivepaper, fabrics, etc., on this plate, and to stretch them into aneven position. An electrically insulated contact pin, adjustableFIG. 1 Schematic Diagram of Inflated Diaphragm Abrasion TesterFIG. 2 One Type of Commercial Inflated Diaphragm Abrasion TesterD3886 99 (2015)

40、3to the thickness of the abradant is mounted into this plate on thelength axis at one of the turning points of the center of theclamp.6.1.5 Some testers can also be equipped with a continuouschanging abradant head which is optional.NOTE 2The machine manufacturer does not provide adequate instruc-tio

41、ns for the use of the continuous changing abradant head. Work is beingdone with the manufacturer to write a set of instructions.6.1.6 Machine Stopping MechanismContact between theadjustable pin on the lower side of the abradant plate and thecontact pin inserted into the center of the diaphragm close

42、s alow-voltage circuit and stops the machine.6.1.7 IndicatorsMeans should be provided for indicatingthe diaphragm pressure, and the number of abrasion cycles (1cycle = 1 double stroke).6.1.8 Fig. 2 shows a commercially available machine thatconforms to the requirements of this method.7. Sampling7.1

43、Lot SampleAs a lot sample for acceptance testing, takeat random the number of rolls of fabric directed in anapplicable material specification or other agreement betweenthe purchaser and the supplier. Consider rolls of fabric to be theprimary sampling unit.NOTE 3An adequate specification or other agr

44、eement between thepurchaser and the supplier requires taking into account the variabilitybetween rolls of fabric and between test specimens from a swatch from aroll of fabric to produce a sampling plan with a meaningful producersrisk, consumers risk, acceptable quality level, and limiting quality le

45、vel.7.2 Laboratory SampleTake a laboratory sample fromeach roll or piece of fabric in the lot sample. The laboratorysample should be full width and at least 50 cm (approximately20 in.) long and should not be taken any closer to the end of theroll or piece of fabric than1m(1yd).7.3 Test SpecimensTest

46、 five specimens from each labora-tory sampling unit. Cut the specimens 112 mm (438 in.) indiameter and space them on a diagonal to represent differentmachine and cross-machine direction areas of the laboratorysampling units. Take no specimen within one tenth of the fabricwidth from the edges.8. Cond

47、itioning8.1 Precondition and condition samples or specimens asdirected in Practice D1776. Consider equilibruim to have beenreached when the increase in mass of the specimen in succes-sive weighings made at intervals of not less than 2 h does notexceed 0.1 % of the mass of the specimen.9. Procedure9.

48、1 Test the specimen in the standard atmosphere for testingtextiles, which is 70 6 2F (21 6 1C) and 65 6 2 % relativehumidity.9.2 Place the specimen over the rubber diaphragm in asmooth condition, clamp the specimen in place without dis-torting it.9.3 Place the abrasive paper or other abradant on the

49、abradant plate under sufficient tension to be held smooth and insuch a position that the contact pin, reaching through a hole inthe abradant, is even with the surface of the abradant. No. 0emery polishing paper is the standard abradant. The methodmay be modified to use other abradants but this informationshould be included in the final report.NOTE 4If the continuous changing abradant head is used, it should benoted that, although the weight of the head is counter-balanced, thebalance changes during use as the paper passes from the back roll to thefront roll un

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1