ASTM D4180-2003 Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers《成型催化剂颗粒和催化剂载体振动填充密度的标准试验方法》.pdf

上传人:sofeeling205 文档编号:516494 上传时间:2018-12-02 格式:PDF 页数:3 大小:40.54KB
下载 相关 举报
ASTM D4180-2003 Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers《成型催化剂颗粒和催化剂载体振动填充密度的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM D4180-2003 Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers《成型催化剂颗粒和催化剂载体振动填充密度的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM D4180-2003 Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers《成型催化剂颗粒和催化剂载体振动填充密度的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 4180 03Standard Test Method forVibratory Packing Density of Formed Catalyst Particles andCatalyst Carriers1This standard is issued under the fixed designation D 4180; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t

2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the vibra-tory packing density of formed catalyst and catalys

3、t carriers.For the purpose of this test, catalyst particles are defined asextrudates, spheres, or formed pellets of 0.8 to 4.8-mm (132 to316-in.) nominal diameter.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This sta

4、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1

5、ASTM Standards:2D 3766 Terminology Relating to Catalysts and CatalysisE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and StatisticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Term

6、inology3.1 DefinitionsSee Terminology D 3766.4. Summary of Test Method4.1 A preconditioned sample of formed catalyst or catalystcarrier is vibrated in a cylinder. The vibratory packing densityis determined from a known mass and vibrated volume.5. Significance and Use5.1 This test method is to be use

7、d for measuring thevibratory packing density of formed particles that will notbreak up during sampling, filling, or vibrating of the measuringcylinder under test conditions.6. Apparatus6.1 Glass Cylinders, capacity 250 mL, feed and measuring.6.2 Vibrator,3conventional hand-held, with hard rubber orm

8、etal impactor.6.3 Feed Funnel, plastic, glass, or metal as shown in Fig. 1.6.4 Ring Stand, Vibrator Holder and Clamps as shown inFigs. 2 and 3.6.5 Desiccator, with a desiccant grade molecular sieve suchas a No. 4A.6.6 Balance having sensitivity of 0.1 g.6.7 Drying Oven.1This test method is under the

9、 jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.02 on Physical-Mechanical Properties.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1988. Last previous edition approved in 1999 as D 418099.2For referenced ASTM

10、 standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of the Wahl Vibrator, Model 4180, 4 in 1, 120-V60-Hz 1

11、1-W known to the committee at this time is Wahl Clipper Corp., Sterling, IL.If you are aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may

12、 attend.FIG. 1 Feed Funnel1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Procedure7.1 Heat an adequate sample(s) at 400 6 15C for not lessthan 3 h. Normally, this treatment can take place in air.However, in the case of materials

13、that might react with air atelevated temperatures (such as prereduced catalysts) the heattreatment should take place in an inert atmosphere. Cool afterheating the test sample(s) in a desiccator or other suitablecontainer to eliminate the possibility of moisture adsorptionprior to testing.NOTE 1These

14、 conditions may not be appropriate for all materials.NOTE 2Since many catalyst formulations are strong adsorbents, theuse of a No. 4A indicating (cobalt-treated) molecular sieve as a desiccat-ing medium is suggested. The desiccant should be regenerated at 220 to260C as required.7.2 Fill a tared feed

15、-glass cylinder with 250 mL of looselypacked, dried catalyst and weigh immediately to the nearest 0.1g.FIG. 2 Assembly of ApparatusFIG. 3 Vibrator HolderD41800327.3 Turn on the vibrator and carefully add the sample(s) tothe measuring cylinder through the feed funnel.7.4 Transfer all the catalyst to

16、the measuring cylinder at auniform rate not less than 2 mL/s or exceeding 3 mL/s. Theentire transfer time should be between 83 and 125 s.7.5 After an additional 60 s turn off vibrator. Read thevibrated volume, V, to the nearest 1 mL by estimating theaverage level of the catalyst surface in the cylin

17、der.8. Calculation8.1 Calculate the vibratory packing density VPD as follows:VPD 5 W/Vwhere:W = mass of catalyst particles, g, andV = volume occupied by catalyst particles in measuringcylinder, mL.8.2 Vibratory packing densities are typically reported tothree significant figures.9. Precision and Bia

18、s49.1 Test ProgramAn interlaboratory study was conductedin which the named property was measured in two separate testmaterials in five separate laboratories. Practice E 691, modifiedfor nonuniform data sets, was followed for the data reduction.9.2 PrecisionPairs of test results obtained by a procedu

19、resimilar to that described in the study are expected to differ inabsolute value by less than 2.772 S, where 2.772 S is the 95 %probability interval limit on the difference between two testresults, and S is the appropriate estimate of standard deviation.Definitions and usage are given in Terminology

20、 E 456 andPractice E 177, respectively.Test Result(consensus mean),kg/L95 % RepeatabilityInterval(within laboratory)kg/L (% of mean)95 % ReproducibilityInterval(between laboratories),kg/L (% of mean)0.68021.19980.003 (0.48)0.007 (0.55)0.013 (1.94)0.041 (3.40)9.3 BiasThe procedure in this test method

21、 has no biasbecause the value of the vibratory packing density can bedefined only in terms of a test method.10. Keywords10.1 carriers; catalyst; packing density; vibratoryASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedi

22、n this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and mu

23、st be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of th

24、eresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C70

25、0, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).4Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR: D32-1018.D4180033

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1