ASTM D4582-2005 Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis《反渗透粘稠性和戴维斯稳定性指数的计算和调整的标准规程》.pdf

上传人:priceawful190 文档编号:517427 上传时间:2018-12-02 格式:PDF 页数:4 大小:128.87KB
下载 相关 举报
ASTM D4582-2005 Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis《反渗透粘稠性和戴维斯稳定性指数的计算和调整的标准规程》.pdf_第1页
第1页 / 共4页
ASTM D4582-2005 Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis《反渗透粘稠性和戴维斯稳定性指数的计算和调整的标准规程》.pdf_第2页
第2页 / 共4页
ASTM D4582-2005 Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis《反渗透粘稠性和戴维斯稳定性指数的计算和调整的标准规程》.pdf_第3页
第3页 / 共4页
ASTM D4582-2005 Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis《反渗透粘稠性和戴维斯稳定性指数的计算和调整的标准规程》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 4582 05Standard Practice forCalculation and Adjustment of the Stiff and Davis StabilityIndex for Reverse Osmosis1This standard is issued under the fixed designation D 4582; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis

2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calculation and adjustment ofthe Stiff and Davis Stability Index (S decreas

3、ing the calcium andalkalinity concentrations; or by changing the ratio of totalalkalinity to free carbon dioxide in the feedwater.5. Significance and Use5.1 In the design and operation of reverse osmosis installa-tions, it is important to predict the calcium carbonate scalingproperties of the concen

4、trate stream. Because of the increase intotal dissolved solids in the concentrate stream and the differ-ences in salt passages for calcium ion, bicarbonate ion, and freeCO2, the calcium carbonate scaling properties of the concen-trate stream will generally be quite different from those of thefeed so

5、lution. This practice permits the calculation of the S however, since many variables changewith acidification, trial and error computations are required todetermine the amount of acid needed to determine the amountof acid needed to obtain the desiredS membrane scaling; reverse osmosis(RO); stability index for RO; Stiff and Davis Stability Index (Sor through the ASTM website(www.astm.org).FIG. 3 Conversion of Calcium and Alkalinity to pCa and pAlkD4582054

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1