ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf

上传人:dealItalian200 文档编号:517815 上传时间:2018-12-03 格式:PDF 页数:9 大小:177.28KB
下载 相关 举报
ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf_第1页
第1页 / 共9页
ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf_第2页
第2页 / 共9页
ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf_第3页
第3页 / 共9页
ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf_第4页
第4页 / 共9页
ASTM D4727 D4727M-2015e1 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes《瓦拢面的和实心的纤维板坯料 (包装级) 和切制形材的标准规格》.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D4727/D4727M 151Standard Specification forCorrugated and Solid Fiberboard Sheet Stock (ContainerGrade) and Cut Shapes1This standard is issued under the fixed designation D4727/D4727M; the number immediately following the designation indicates theyear of original adoption or, in the case

2、 of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1NOTECorrections w

3、ere made editorially in March 2016.1. Scope1.1 This specification covers fiberboard primarily used forthe fabrication of boxes and interior details such as pads,sleeves, liners, partitions, die-cut sheets, etc.1.2 The performance of fiberboard boxes is largely depen-dent on the paper components from

4、 which they are fabricatedand, in the case of corrugated boxes, on the flute structure aswell. Therefore, a variety of grades reflecting varied perfor-mance levels are specified.1.3 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, th

5、eSI units are shown in brackets. The values stated in eachsystem are not exact equivalents; therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.See IEEE/ASTM-SI-10 for conversion of units.1.4 The followin

6、g safety hazards caveat pertains only to thetest portion, Sections 8 and 9, of this specification:Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpracti

7、ces and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D585 Practice for Sampling and Accepting a Single Lot ofPaper, Paperboard, Fiberboard, and Related Product(Withdrawn 2010)3D996 Terminology of Packaging and Distribution Environ-men

8、tsD3950 Specification for Strapping, Nonmetallic (and Join-ing Methods)D3951 Practice for Commercial PackagingD3953 Specification for Strapping, Flat Steel and SealsD4169 Practice for Performance Testing of Shipping Con-tainers and SystemsD4675 Guide for Selection and Use of Flat Strapping Ma-terial

9、s1D5118/D5118M Practice for Fabrication of Fiberboard Ship-ping BoxesD5168 Practice for Fabrication and Closure of Triple-WallCorrugated Fiberboard ContainersD5639/D5639M Practice for Selection of Corrugated Fiber-board Materials and Box Construction Based on Perfor-mance RequirementsD6039/D6039M Sp

10、ecification for Open and Covered WoodCratesD6199 Practice for Quality of Wood Members of Containersand PalletsE162 Test Method for Surface Flammability of MaterialsUsing a Radiant Heat Energy SourceE662 Test Method for Specific Optical Density of SmokeGenerated by Solid MaterialsIEEE/ASTM-SI-10 Stan

11、dard for Use of the InternationalSystem of Units (SI): The Modern Metric System2.2 TAPPI Standards:4T 402 Standard Conditioning and Testing AtmosphereT 410 Weight per Unit Area (Basis Weight or Substance)T411Thickness (Caliper) of Paper and PaperboardT 441 Water Absorptiveness of Sized (Non-Bibulous

12、) Paperand Paperboard (Cobb Test)1This specification is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.27 on FiberboardShipping Containers, Containerboard and Related Structures and Materials.Current edition approved Oct. 1, 2015. Publis

13、hed December 2015. Originallyapproved in 1987. Last previous edition approved in 2012 as D4727/D4727M 12.DOI: 10.1520/D4727_D4727M-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume info

14、rmation, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from Technical Association of the Pulp and Paper Industry (TAPPI),15 Technology Parkway South, Norcross, GA 30092, http:/www.tappi.o

15、rg.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1T 803 Puncture and Stiffness Test of Container BoardT 810 Bursting Strength of Corrugated and Solid FiberboardT811Edge Crush TestT 812 Ply Separation of Solid and Corrugated Fiberboar

16、d(Wet)2.3 Other Standards:National Motor Freight Classification5Uniform Freight Classification6ISO 535 Paper and BoardDetermination of WaterAbsorptionCobb Method73. Terminology3.1 General definitions for packaging and distribution envi-ronments are found in Terminology D996.4. Classification4.1 Type

17、Corrugated fiberboard (CF).4.1.1 ClassesDomestic (D) and domestic/fire retardant(D/FR).4.1.1.1 VarietySinglewall (SW).(1) Burst Grades125, 150, 175, 200, 250, 275, and 350.8(2) ECT Grades23, 26, 29, 32, 40, 44, and 5594.1.1.2 VarietyDoublewall (DW).(1) Burst Grades200, 275, 350, 400, 500 and 600.8(2

18、) ECT Grades42, 48, 51X, 61X, 71X, and 82X.9,104.1.1.3 VarietyTriplewall (TW).(1) Grades700, 900, 1100, and 1300.114.1.2 ClassesWeather-resistant (WR) and weather-resistant/fire retardant (WR/FR).4.1.2.1 VarietySinglewall (SW).(1) GradesV3c, and W5c.4.1.2.2 VarietyDoublewall (DW).(1) GradesV11c, V13

19、c, and V15c4.1.3 ClassesWater and water-vapor resistant (WWVR)and water and water-vapor resistant/fire retardant (WWVR/FR).4.1.3.1 VarietySinglewall (SW).(1) GradesV3c WWVR, W5c WWVR.4.1.3.2 VarietyDoublewall (DW).(1) GradesV11c WWVR and V13c WWVR.4.2 TypeSolid Fiberboard (SF).4.2.1 ClassDomestic (D

20、) and Domestic/Fire Retardant(D/FR).4.2.1.1 Grades125, 175, 200, 275, 350, 500 and 600.84.2.2 ClassWeather-resistant (WR) and WeatherResistant/Fire Retardant (WR/FR).4.2.2.1 GradesV2s, V3s, V4s, W5s and W6s.5. Ordering Information5.1 Purchasers should select the preferred options permittedherein, an

21、d include the following information in procurementdocuments:5.1.1 Title, number and date of this specification,5.1.2 Type, class, variety and grade (see 4.1 and 7.1),5.1.3 Size of sheet, pad, etc. (see 7.3.1.4),5.1.4 Center line of score to center line of score or sheetedge (see 7.3.1.4),5.1.5 Flute

22、 design of type corrugated fiberboard; variety SWand DW (see 6.4 and 6.4.1),5.1.6 Mill run or trimmed sheets,5.1.7 Dimensional direction of flutes of type CorrugatedFiberboard (CF),5.1.8 Packing and marking requirements (see S3 and S4),and5.1.9 Palletization requirements (see S3.1.1.1).6. Materials

23、and ManufactureMATERIALS6.1 Paperboard Components:6.1.1 Facings and Outer PliesThe facings of corrugatedfiberboard and the plies of solid fiberboard shall have bendingqualities to satisfy the requirements of 7.6. The paperboardcomponents of weather-resistant class material shall be treatedwith a sui

24、table wet strength resin to make them water resistant.Similarly, the paperboard components of fire retardant classmaterial shall be treated to make them fire retardant to meet therequirements of 7.7.1 and 7.7.2.6.1.1.1 Outer Facing of Corrugated Fiberboard, Water- andWater Vapor Resistant ClassOne o

25、uter facing of this materialshall be a composite sheet comprised of one ply of sized, wetstrength kraft linerboard laminated to a ply of linerboardconforming to 6.1.1 with a minimum of 6 lb/1000 ft229 g/m2of polyethylene. The sized ply shall be on the exterior side ofthe facing, with the unsized lin

26、erboard next to the corrugatedmedium. At the suppliers option, both plies of linerboard maybe of a sized wet strength material.6.1.1.2 Facing and Outer Plies Pertaining to HazardousMaterials PackagingThe facings of corrugated fiberboardand the plies of solid fiberboard shall have water resistancequa

27、lities to satisfy the following requirement from ISO 535:(1) Water resistance of the outer surface shall be such thatthe increase in mass, as determined in a test carried out over aperiod of 30 min by the Cobb test method of determining waterabsorption, is not greater than 155 g/m2.6.1.2 Corrugated

28、Medium(1) The corrugating medium of corrugated fiberboard shallbe made from any suitable fibers.(2) The corrugating medium components of Weather Re-sistant classes and the Water and Water Vapor Resistant classesshall be treated with a suitable wet strength resin to make themwater resistant.6.2 Adhes

29、ives:5National Motor Freight Classification is available from National Motor FreightTraffic Association, Inc. (NMFTA), 1001 N. Fairfax St., Suite 600, Alexandria, VA22314, http:/www.nmfta.org.6Uniform Freight Classification is available from Rail Publication Service, 151Ellis St. N.E., Suite 260, At

30、lanta, GA 303356021.7Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.8Grade numbers for single and double wall corrugated varieties and solid fibertypes refer to the bursting strength in lb/in.2as determined by TAPPI T 810

31、.9Grade numbers for single and double wall corrugated varieties refer to the edgecrush in lb/in. as determined by TAPPI T 811.10Grade numbers for double wall corrugated varieties with an “X” indicate thatthe value should be used as a guide and that the actual required edge crush test valueis yet to

32、be determined.11Grade number for triplewall refers to the dry puncture resistance in units asdetermined by TAPPI T 803.D4727/D4727M 15126.2.1 Domestic (D) and Domestic/Fire Retardant (D/FR)ClassesThe adhesive used in the construction of thedomestic/fire retardant class of fiberboard should be that w

33、hichis commercially used by the industry, and shall enable the enditem to meet the strength requirements specified herein.6.2.2 Weather-Resistant (WR) and Weather-Resistant/FireRetardant (WR/FR) ClassesThe adhesive used in the con-struction of Weather-Resistant classes of fiberboard shall bewater-re

34、sistant to the extent that the end item will meet therequirements of this specification (see 7.4).6.2.3 Water and Water Vapor-Resistant (WWVR) and Waterand Water Vapor-Resistant/Fire Retardant (WWVR/FR)ClassesThe adhesive used in the construction of Water andWater Vapor-Resistant classes of fiberboa

35、rd shall be water-resistant to the extent that the end item will meet the require-ments of this specification (see 7.4). Paragraph 7.4 also appliesto the polyethylene linerboard bonds in the laminated facings.6.3 Triplewall and Triplewall/Fire Retardant CorrugatedFiberboard ClassesTriplewall corruga

36、ted fiberboard, domes-tic and domestic/fire retardant classes, non-weather-resistantand weather-resistant in both regular and fire-retardant classesshall conform to the requirements of Practice D5168.CONSTRUCTION6.4 Corrugated FiberboardCorrugated fiberboard shall bemade with two, three, or four fac

37、ings for single, doublewall ortriplewall, respectively. Each facing shall be separated by andsecurely adhered to the corrugated medium.6.4.1 FlutesThe number of flutes per unit length offiberboard shall be as follows or as specified:Flutes/ft Flutes/m FluteHeight (in.)FluteHeight(mm)A-Flute 30 to 39

38、 98 to 128 0.1575 to0.22104.00 to5.61B-Flute 45 to 53 147 to 174 0.0787 to0.11022.00 to2.80C-Flute 35 to 45 115 to 148 0.1300 to0.15753.30 to4.00E-Flute 70 to 98 229 to 321 0.0445 to0.05501.13 to1.406.5 Solid FiberboardSolid fiberboard shall be constructedby laminating plies securely and continuousl

39、y together.6.5.1 Domestic:6.5.1.1 Grades 125 and 175The fiberboard shall consistof not less than two plies of components.6.5.2 Grades 200 through 600The fiberboard shall consistof not less than three plies of components.6.6 Scored SheetsThe scorelines on scored sheets shallshow no visual continuous

40、surface break greater than specifiedin 7.6 when tested as specified in 9.3.6.7 Pads and Cut ShapesPads and cut shapes shall bemade in accordance with specified dimensions or drawings.6.7.1 Pads and cut shapes may be single sheets, or may bemade by laminating two or more sheets of specified types and

41、classes of material to the specified thickness.7. Physical Requirements7.1 Corrugated Fiberboard:7.1.1 Domestic and Domestic/Fire Retardant Classes, AllVarieties:7.1.1.1 FacingsThe facings shall conform to the require-ments in Table 1 when tested as specified in 9.1.2.7.1.1.2 Corrugating MediumThe c

42、orrugating medium forthe domestic/fire retardant classes of corrugated fiberboardshall weigh not less than 26 lb/1000 ft2127 g/m2, or asspecified, when tested in accordance with 9.1.2.TABLE 1 Type CF (Corrugated Fiberboard), Domestic (D) andDomestic/Fire Retardant Classes (D/FR)NOTE 1Select either b

43、urst strength or edge crush strength require-ment. (While a choice of either burst or edge crush fiberboard isacceptable, their performance may not be equivalent. Refer to 4.1 and7.1.1.3.)Part ABurst or Puncture Strength Related RequirementsVarietyCombined WeightFacings Only, minBursting Strength, D

44、ry,minAlb/1000 ft2g m2 psi kPaSW 52 254 125 862SW 66 322 150 1034SW 75 366 175 1207SW 84 410 200 1379SW 111 542 250 1724SW 138 674 275 1896SW 180 879 350 2413DW 92 449 200 1379DW 110 537 275 1896DW 126 615 350 2413DW 180879 4002758DW 2221084 500 3447DW 2701318 600 4137Grade PunctureBin.oz/inchesof t

45、ear (J)TW 700 168 820 700 21TW 900 222 1084 900 27TW 1100 264 1289 1100 33TW 1300 360 1758 1300 39Part BEdge Crush Strength RequirementsVariety Edge Crush Strength minClb/in. kN/mSW 23 4.0SW 26 4.6SW 29 5.1SW 32 5.6SW 40 7.0SW 44 7.7SW 55 9.6DW 42 7.4DW 48D8.4DW 51D8.9DW 61D10.7DW 71D12.4DW 82D14.4A

46、Only one burst of the initial six may fall beneath the minimum required. Domesticboard and domestic fire/retardant failing to pass this test will be accepted if, in aretest consisting of 24 bursts (12 from each side of the board), not more than 4bursts fall below the minimum value required.BA minimu

47、m of four puncture tests, conducted in accordance with TAPPI T 803must be made and only one puncture test will be permitted to fall below thespecified minimum value.COnly one edge crush test of the initial six may fall below the minimum required,and that one test cannot fall below the specified mini

48、mum value by more than10 %. Domestic board and domestic fire/retardant failing to pass this test will beaccepted if, in a retest consisting of 24 edge crush tests, not more than 4 crush testresults fall below the minimum value, and none of those tests fall below thespecified minimum value by more th

49、an 10 %.DValues subject to confirmation.D4727/D4727M 15137.1.1.3 End ItemDomestic and domestic/fire retardantclasses of corrugated fiberboard, constructed as specified in6.4, shall conform to the requirements in Table 1 for burstingstrength or puncture resistance or edge crush (as specified)when tested as specified in 9.1.3, 9.1.5, or 9.1.8. (See compli-ance statement following Table 1 for Burst and Edge Crush.)7.1.2 Weat