ASTM D4731-2013 Standard Specification for Hot-Application Filling Compounds for Telecommunications Wire and Cable《电信电线和电缆用热充填化合物的标准规格》.pdf

上传人:registerpick115 文档编号:517826 上传时间:2018-12-03 格式:PDF 页数:4 大小:84.05KB
下载 相关 举报
ASTM D4731-2013 Standard Specification for Hot-Application Filling Compounds for Telecommunications Wire and Cable《电信电线和电缆用热充填化合物的标准规格》.pdf_第1页
第1页 / 共4页
ASTM D4731-2013 Standard Specification for Hot-Application Filling Compounds for Telecommunications Wire and Cable《电信电线和电缆用热充填化合物的标准规格》.pdf_第2页
第2页 / 共4页
ASTM D4731-2013 Standard Specification for Hot-Application Filling Compounds for Telecommunications Wire and Cable《电信电线和电缆用热充填化合物的标准规格》.pdf_第3页
第3页 / 共4页
ASTM D4731-2013 Standard Specification for Hot-Application Filling Compounds for Telecommunications Wire and Cable《电信电线和电缆用热充填化合物的标准规格》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D4731 13 An American National StandardStandard Specification forHot-Application Filling Compounds for TelecommunicationsWire and Cable1This standard is issued under the fixed designation D4731; the number immediately following the designation indicates the year oforiginal adoption or, i

2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers a variety of petroleum-basedand other compounds used fo

3、r filling the air spaces in telecom-munications wires and cables (both electrical and fiber optic)for the purpose of preventing water and other undesirable fluidsfrom entering or migrating through the cable structure. (Forrelated standards see Specifications D4730 and D4732).1.2 A hot-application co

4、mpound is a material that requiresmelting in order to be applied as a liquid and its melting pointaffects its performance in the finished cable product.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units tha

5、t are provided for informa-tion only and are not considered standard.2. Referenced Documents2.1 ASTM Standards:2D6 Test Method for Loss on Heating of Oil and AsphalticCompoundsD92 Test Method for Flash and Fire Points by ClevelandOpen Cup TesterD97 Test Method for Pour Point of Petroleum ProductsD12

6、7 Test Method for Drop Melting Point of PetroleumWax, Including PetrolatumD150 Test Methods for AC Loss Characteristics and Permit-tivity (Dielectric Constant) of Solid Electrical InsulationD257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD445 Test Method for Kinematic Viscos

7、ity of Transparentand Opaque Liquids (and Calculation of Dynamic Viscos-ity)D938 Test Method for Congealing Point of PetroleumWaxes, Including PetrolatumD1500 Test Method for ASTM Color of Petroleum Products(ASTM Color Scale)D2161 Practice for Conversion of Kinematic Viscosity toSaybolt Universal Vi

8、scosity or to Saybolt Furol ViscosityD3895 Test Method for Oxidative-Induction Time of Poly-olefins by Differential Scanning CalorimetryD3954 Test Method for Dropping Point of WaxesD4565 Test Methods for Physical and Environmental Per-formance Properties of Insulations and Jackets for Tele-communica

9、tions Wire and CableD4568 Test Methods for Evaluating Compatibility BetweenCable Filling and Flooding Compounds And PolyolefinWire and Cable MaterialsD4730 Specification for Flooding Compounds for Telecom-munications Wire and CableD4732 Specification for Cool-Application Filling Com-pounds for Telec

10、ommunications Wire and CableD4872 Test Method for Dielectric Testing of Wire and CableFilling Compounds3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 filling materialany of several materials used to fillthe air spaces in the cores of multi-conductor insulated wiresand cables,

11、 or between buffer tubes covering optical fibers, orwithin such buffer tubes, or any combination of these configu-rations and any other cable components, for the purpose ofexcluding water and other undesirable fluids; especially withregard to telecommunications wire and cable, including opticalcable

12、, intended for outside aerial, buried, or undergroundinstallations.3.1.2 producerthe primary manufacturer of the material.3.1.3 suppliersjobbers and distributors as distinct fromproducers.4. Classification4.1 Two basic types of filling compounds are covered, asfollows:4.1.1 Type IGeneral-purpose fil

13、ling compounds includeall materials to be used for filling cables that are not required1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shield

14、ings and Coveringsfor Electrical and Telecommunication Wires and Cables. Subcommittee D02.10contributed in the development of this standard.Current edition approved May 1, 2013. Published July 2013. Originally approvedin 1987. Last previous edition approved in 2008 as D473102 (2008)1. DOI:10.1520/D4

15、731-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of th

16、is standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1to function under electrical stress (for example, all dielectricfiber-optic cable), including filling compounds for fiber-opticloose buffer tubes.4.1.2 Type IIElectrical-type

17、filling compounds includematerials having prescribed electrical properties and used forfilling wires and cables that are required to function fully orpartially under electrical stress (including hybrid fiber-opticcable).5. Ordering Information5.1 Orders for material under this specification shall in

18、cludethe following information:5.1.1 Quantity (mass or volume) of each item,5.1.2 Generic name of the material, such as hot-applicationcable filling material,5.1.3 Type of material: Type I, General Purpose or Type II,Electrical,5.1.4 How Furnished: drums or barrels, tank cars or tanktrucks, and the

19、like,5.1.5 Certification, if required (Section 14).5.1.6 This specification designation, and5.1.7 Any special requirements, as listed in 7.2, 9.2 and 10.2and in Sections 11 and 12 that apply.6. Materials and Manufacture6.1 The material and manufacturing methods used shall besuch that the resulting p

20、roducts will conform to the propertiesand characteristics prescribed in this specification.7. Chemical Composition7.1 The chemical composition of these materials is notspecified. The material shall be of a chemical compositionsuitable for the intended purpose and that meets the require-ments of this

21、 specification as hereinafter stated.7.2 When agreed upon between the producer and thepurchaser, antioxidant stabilizing additives shall be included inthe compound formulation to assure specified results in thermaloxidative stability testing.7.3 Once established, the producer shall not change thecom

22、position of the compound in successive lots of materialwithout prior approval of the purchaser.8. Electrical Properties8.1 When a Type II (electrical) filling compound isspecified, the compound shall exhibit the electrical propertiesin 8.1.1 and 8.1.2. The electrodes used shall be parallel platesof

23、solid or foil metal of a size and shape appropriate for thespecimen holder. Other electrodes are used as agreed uponbetween the producer and the purchaser. The voltage appliedand the time of electrification shall be appropriate for theinstrumentation used and as agreed upon between the producerand t

24、he purchaser.8.1.1 When tested, in accordance with Test Methods D150or D4872, at a temperature of 23 6 3 C, the dissipation factorshall not exceed 0.0010 at a frequency of 1 MHz and thepermittivity shall not exceed 2.30.8.1.1.1 Warning If any bubbles are formed in melting thecompound to prepare the

25、specimen for test, the sample shall bediscarded and a new sample selected.8.1.2 When tested, in accordance with Test Methods D257,at a temperature of 23 6 3 C, the volume resistivity shall benot less than 1013cm.9. Physical Properties9.1 Filling compound furnished under this specificationshall inhib

26、it the corrosion of any metallic wire and cableelements with which it comes in contact, while serving as aradial and longitudinal barrier to moisture transmission. Con-tact of the filling compound with any cable component shallnot cause degradation of performance of the cable component.The filling c

27、ompound shall display adhesive properties toprovide adhesion between metallic sheath elements and theouter jacket materials of wire and cable.9.2 Other Physical Properties:9.2.1 Other property requirements such as Flash Point (forexample, Test Method D92), high-temperature drip/oil separa-tion (syne

28、resis) in the raw material state, and the like, shall beas agreed upon between the producer and the purchaser.(Additional information on oil separation is given in theappendix of this specification.)10. General Requirements10.1 All filling compounds manufactured in accordancewith this specification

29、shall meet the following requirements:10.1.1 HomogeneityThe compound shall be homoge-neous and free of agglomerates.10.1.2 Color and OpacityThe compound shall be asnearly colorless as is commercially feasible, consistent with therequirements of the end products for which the filling com-pound is int

30、ended. In general, identification of cable memberscoated with filling compound shall not be significantly inhib-ited because of filling-compound color or opacity.10.1.3 Color StabilityAfter aging a specimen of fillingcompound in a suitable container for a period of 120 6 1h(5days) at a temperature o

31、f 266 F (130 C) in a static air oven,measure the compound color in accordance with Test MethodD1500. Unless otherwise specified, the color of the agedcompound shall not exceed 2.5.10.1.4 Foreign MaterialThe compounds shall be free ofdirt, metallic particles, and other foreign matter.10.2 Other Prope

32、rtiesOther property requirements suchas Volatility (for example, Test Method D6), thermal oxidativestability (for example, testing similar to Test Method D3895),corrosion prevention and the like, shall be as agreed uponbetween the producer and the purchaser.NOTE 1If Test Method D6 is referenced, a t

33、est cycle of 22 h at 107 C(225 F) is recommended in lieu of the 163 C (325 F) temperaturerequired by Test Method D6.11. Temperature Characteristics11.1 Raw material temperature characteristics, such as PourPoint (for example, Test Method D97), Drop-Melting Point(for example, Test Method D127), Visco

34、sity (for example, TestMethod D445 and Practice D2161), Congealing Point (forD4731 132example, Test Method D938), Drop Point (for example, TestMethod D3954), if needed, shall be as agreed upon between theproducer and the purchaser.NOTE 2Although cited in 11.1, Test Method D127 is “not” a preferredme

35、thod for determining melting point of wire and cable filling compoundssince results tend to be too high to be useful in predicting materialbehavior in the cable-filling process. However, this may be a good test forquality control purposes. (Refer to the appendix of this specification foradditional i

36、nformation.)11.2 The purchaser (individual cable manufacturer or other)shall specify any other expected temperature conformancerequirements (high and low) needed to ensure compliance withsuch end product requirements as cable drip-out temperature,cold bend, low temperature flexibility, and the like

37、(forexample, Test Methods D4565).12. Compatibility with other Materials12.1 It is the responsibility of the purchaser to ensure thatthe filling compound ordered is suitable for the intendedapplication and is compatible with any other components thatit comes into contact with.12.2 The purchaser shall

38、 specify the materials that thecompound must be compatible with when tested in accordancewith Test Methods D4568.13. Quality Assurance13.1 Responsibility for Inspection and TestsUnless other-wise specified in the contract or the purchase order, theproducer is responsible for the performance of all i

39、nspectionand test requirements specified herein. The producer shall usehis own or any other suitable facilities for the performance ofthese inspection and test requirements, unless otherwise statedby the purchaser in the order or at the time of the contractsigning. The purchaser shall have the right

40、 to perform any ofthe inspections and tests set forth in this specification wheresuch inspections are deemed necessary to ensure that thematerial conforms to the prescribed requirements.13.2 Each producer shall establish written nominal valuesand tolerances for the material properties routinely chec

41、ked.For properties not routinely checked, typical values shall bespecified. Once these values have been accepted by thepurchaser, the producer shall not ship material that deviatesfrom these limits without prior notification to and the approvalof the purchaser.13.3 An inspection lot shall consist of

42、 an identifiable quan-tity of the same material subjected to inspection at one time.14. Certification14.1 The producer or supplier shall, on request, furnish tothe purchaser a certificate stating that each lot has beensampled, tested, and inspected in accordance with thisspecification, and meets the

43、 specified requirements.15. Packaging and Package Marking15.1 PackagingQuantities of the filling compound arepackaged in standard 55 gal (210 L) drums or in tank carscapable of protecting the material from contamination duringshipment. Smaller containers are also used as agreed uponbetween the produ

44、cer and the purchaser.15.2 Package MarkingShipping containers shall bemarked with the name of the manufacturer, trade name, type ofmaterial, lot number, mass or volume, and the date of manu-facture.16. Keywords16.1 compatibility; filling compounds; hot application; tele-communications wire and cable

45、APPENDIX(Nonmandatory Information)X1. DISCUSSION OF FILLING COMPOUND PROPERTIESX1.1 Most, but not all, wire and cable filling materials aresemi-solid in their natural state but are introduced into a wireor cable structure in a molten state at a relatively hightemperature. The performance properties

46、of such wire andcable filling materials (as raw materials and in finishedproducts) is not completely understood in spite of the fact thatsuch materials have been in regular use for many years, andnumerous technical papers have been written on the subject.Since there is no one test or series of tests

47、 that can be appliedto these raw materials that will guarantee desired performancein a finished electrical or optical wire and cable product, manyof the detailed requirements of this specification must be left tothe discretion and agreement of the producer and the purchaser.In reaching an agreement

48、upon these detailed requirements, thefollowing factors are among those that need to be consideredby the parties involved:X1.1.1 In evaluating properties such as melting point, flowperformance, and the like, the heat history of the fillingmaterial prior to the test must be considered. Slow coolingfro

49、m a molten state can, for example, depress the melting pointof the material. In making tests, special care must be exercisedto ensure that the material to be tested is free of any “hidden”heat history.X1.1.2 Although opinion on this point is not unanimous, themelting point of shock-cooled material is, in most instances, ofmost relevance to electrical cable manufacturers. The cablemanufacturing process used with cable filling materials will, inD4731 133most cases, ensure shock cooling to assure that the meltingpoint is not depressed.Ahigh melting point is