ASTM D4970 D4970M-2016e3 Standard Test Method for Pilling Resistance and Other Related Surface Changes of Textile Fabrics Martindale Tester《纺织品抗起球性和其他相关表面变化的标准试验方法 马丁代尔试验机》.pdf

上传人:赵齐羽 文档编号:518551 上传时间:2018-12-03 格式:PDF 页数:4 大小:132.50KB
下载 相关 举报
ASTM D4970 D4970M-2016e3 Standard Test Method for Pilling Resistance and Other Related Surface Changes of Textile Fabrics Martindale Tester《纺织品抗起球性和其他相关表面变化的标准试验方法 马丁代尔试验机》.pdf_第1页
第1页 / 共4页
ASTM D4970 D4970M-2016e3 Standard Test Method for Pilling Resistance and Other Related Surface Changes of Textile Fabrics Martindale Tester《纺织品抗起球性和其他相关表面变化的标准试验方法 马丁代尔试验机》.pdf_第2页
第2页 / 共4页
ASTM D4970 D4970M-2016e3 Standard Test Method for Pilling Resistance and Other Related Surface Changes of Textile Fabrics Martindale Tester《纺织品抗起球性和其他相关表面变化的标准试验方法 马丁代尔试验机》.pdf_第3页
第3页 / 共4页
ASTM D4970 D4970M-2016e3 Standard Test Method for Pilling Resistance and Other Related Surface Changes of Textile Fabrics Martindale Tester《纺织品抗起球性和其他相关表面变化的标准试验方法 马丁代尔试验机》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D4970/D4970M 163Standard Test Method forPilling Resistance and Other Related Surface Changes ofTextile Fabrics: Martindale Tester1This standard is issued under the fixed designation D4970/D4970M; the number immediately following the designation indicates theyear of original adoption or,

2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEIn 10.1, the standard atmosphere for testing textiles shown in brackets was corrected f

3、rom 70 6 20F to70 6 2F in April 2017.2NOTEIn 6.6.2, the conversion of 105 mm was corrected to 4.13 in. editorially in June 2017.3NOTEIn 8.2, “a pair” was editorially corrected to “four pairs” to match the language in 13.2.1 in January 2018.1. Scope1.1 This test method covers the determination of the

4、 resis-tance to the formation of pills and other related surface changeson textile fabrics using the Martindale tester. The proceduregenerally is applicable to all types of fabrics, being particularlysuitable for woven fabrics.NOTE 1For other methods, if testing the pilling resistance of textiles,re

5、fer to Test Methods D3511/D3511M, D3512/D3512M, and D3514.1.2 This test method is not suitable for fabrics thicker than3 mm 0.125 in. because such fabrics cannot be mounted inthe specimen holder.1.3 The fabric may be laundered or dry cleaned beforetesting.1.4 The values stated in either SI units or

6、inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This standard does not purp

7、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standar

8、d was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Refe

9、renced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD3511/D3511M Test Method for Pilling Resistance andOther Related Surface Changes of Textile Fabrics: BrushPilling TesterD3512/D3512M Test Method for Pilling Resistance andOther Related Surface Changes of Textile Fabrics: Ran-do

10、m Tumble Pilling TesterD3514 Test Method for Pilling Resistance and Other RelatedSurface Changes of Textile Fabrics: Elastomeric PadD4850 Terminology Relating to Fabrics and Fabric TestMethodsD7018 Terminology Relating to Glass Fiber and Its Products2.2 ASTM Adjuncts:3ADJD3512 Set of 5 Photographic

11、Standards for RandomTumble Pilling Test3. Terminology3.1 For all terminology relating to D13.59, Fabric TestMethods, General, refer to Terminologies D4850 and D7018.3.1.1 The following terms are relevant to this standard:cycle, fuzz, movement, pilling resistance, pills.3.2 For all other terms relate

12、d to textiles, refer to Terminol-ogy D123.4. Summary of Test Method4.1 Pilling and other changes in the surface appearance,such as fuzzing, that occur in normal wear are simulated on alaboratory testing machine. Fabrics are mounted on the Mar-tindale Tester, and the face of the test specimen is rubb

13、ed1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.60 on Fabric Test Methods,Specific.Current edition approved Jan. 1, 2016. Published February 2016. Originallyapproved in 1999. Last previous edition approved in 2010 as

14、 D4970 101. DOI:10.1520/D4970-16E03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM Inte

15、rnational Headquarters. Order Adjunct No.ADJD3512.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the

16、Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1against the face of the same mounted fabric in the form of ageometric figure, that is, a straight line, which becomes a

17、gradually widening ellipse, until it forms another straight linein the opposite direction and traces the same figure again underlight pressure for a specific number of movements. The degreeof fabric pilling or surface appearance change produced by thisaction is evaluated by comparison of the tested

18、specimen withvisual standards that may be actual fabrics, or photographs offabrics, showing a range of pilling resistance. The observedresistance to pilling is reported using an arbitrary rating scale.5. Significance and Use5.1 Acceptance TestingThis method of testing fabricsresistance to pilling is

19、 not recommended for acceptance testing.If it is used for acceptance testing, it should be used withcaution because interlaboratory data are not available. In somecases the purchaser or supplier may have to test a commercialshipment of one or more specific materials by the best availablemethod even

20、though the method has not been recommended foracceptance testing. Although this test method is not recom-mended for acceptance testing, it is useful because it is usedwidely outside the United States.5.2 If there is a disagreement arising from differences invalues reported by the purchaser and the s

21、upplier when usingthis test method, the statistical bias, if any, between thelaboratory of the purchaser and the laboratory of the suppliershould be determined with comparison being based on testingspecimens randomly drawn from one sample of material of thetype being evaluated. Competent statistical

22、 assistance is rec-ommended for the investigation of bias. A minimum of twoparties should take a group of test specimens, which are ashomogeneous as possible and which are from a lot of materialof the type in question. The test specimens then should beassigned randomly in equal numbers to each labor

23、atory fortesting. The average test results from the two laboratoriesshould be compared using an acceptable statistical protocol andprobability level chosen by the two parties before the testing isstarted. Appropriate statistical disciplines for comparing datamust be used when the purchaser and suppl

24、ier cannot agree. Ifa bias is found, either its cause must be found and corrected, orthe purchaser and the supplier must agree to interpret futureresults with consideration for the known bias.5.3 The pilling of textile fabrics is a very complex propertybecause it is affected by many factors that inc

25、lude type of fiberor blends, fiber dimensions, yarn and fabric construction, andfabric finishing treatments. The pilling resistance of a specificfabric in actual wear varies more with general conditions of useand individual wearers than in replicate fabric specimenssubjected to controlled laboratory

26、 tests. This experience shouldbe borne in mind when adopting levels of acceptability for aseries of standards.5.4 Finishes and fabric surface changes may exert a largeeffect on pilling. It is recommended that fabrics be tested afterlaundering or drycleaning, or both. Testing before refurbishingalso

27、may be advisable. Prior agreement between interestedparties should determine the state of the test.5.5 Pills vary appreciably in size and appearance anddepend on the presence of lint and degree of color contrast.These factors are not evaluated when pilling is rated solely onthe number of pills. The

28、development of pills may be accom-panied by other surface phenomena, such as loss of cover,color change, or the development of fuzz. Since the overallacceptability of a specific fabric is dependent on both thecharacteristics of the pills and the other factors affecting thesurface appearance, it is s

29、uggested that fabrics tested in thelaboratory be evaluated subjectively with regard to theiracceptability and not rated solely on the number of pillsdeveloped.Aseries of standards, based on graduated degrees ofsurface change of the fabric type being tested, may be set up toprovide a basis for subjec

30、tive ratings. The visual standards aremost advantageous when the laboratory test specimens corre-late closely in appearance with worn fabrics and show a similarratio of pills to fuzz. Counting the pills and weighing theirnumber with respect to their size and contrast, as a combinedFIG. 1 Martindale

31、Abrasion TesterFIG. 2 Apparatus for Fabric EvaluationD4970/D4970M 1632measure of pilling resistance, is not recommended because ofthe excessive time required for counting, sizing, and calcula-tion.5.6 The degree of fabric pilling is evaluated by comparingthe tested specimens with visual standards, w

32、hich may beactual fabrics or photographs of fabrics, showing a range ofpilling resistance. The observed resistance to pilling is reportedon an arbitrary scale ranging from 5 to 1 (no pilling to verysevere pilling).5.7 This test method is applicable to a wide variety ofwoven and knitted fabrics that

33、vary in pilling propensity as aresult of variations in fiber, yarn and fabric structure, andfinish. The applicability of this test method to nonwovenfabrics has not been determined.6. Apparatus and Materials6.1 Martindale Tester (see Fig. 1). Using a lissajous figureof 60 mm as described in Terminol

34、ogy D4850 and having a38 mm sample holder.NOTE 2Apparatus and accessories are available commercially.6.2 Standard Felt, of mass 750 6 50 g/m222 6 1.5 oz/yd2and 3 6 0.3 mm 0.12 6 0.01 in. thick.6.3 Polyurethane Foam Backing0.12 6 0.04 in. 3 6 0.01mm thick, 1.94 lbf/ft329 to 31 kg/m3 density, and 38.2

35、3 to47.22 lbf 170 to 210 N hardness.NOTE 3Apparatus and accessories are available commercially.6.4 Apparatus for Fabric EvaluationFacilities for illumi-nation (cool white fluorescent tube) and simultaneous viewingtest specimens and fabric or photographic rating standards.Apparatus and options for vi

36、sual evaluation are listed in Table1.6.5 Standard In-House Pilling Test Fabric, having an estab-lished pilling resistance rating for checking machine perfor-mance. No universal standard fabric is available. Each testfacility must decide on an appropriate fabric.6.6 Rating Standards:6.6.1 Fabric, a s

37、eries of tested specimens of a specific fabrictype, which show degrees of pilling or other distortion, or both,for the fabric to be tested. Store the fabric rating standards andhandle them under conditions that will preserve their originalform and appearance. Mounting with thick cardboard framingaro

38、und the specimens is recommended.6.6.2 PhotographicA set of five photographs 105 mm4.13 in., numbered 1 to 5, illustrating varying degrees ofpilling from “very severe pilling” to “no pilling.”36.6.3 Digital imaging or rating system, or both.6.7 Fabric Punches or Press Cutters, 38 mm 1.5 in. and140 m

39、m 5.5 in. in diameter.6.8 Facilities for Laundering Samples, if needed.6.9 Facilities for Drycleaning Samples, if needed.7. Sampling7.1 Primary Sampling UnitConsider rolls of fabric orfabric components of fabricated systems to be the primarysampling unit, as applicable.7.2 Laboratory Sampling UnitFr

40、om each primary sam-pling unit take one full-width piece of fabric that is 1 m 1 ydin length along the selvage (machine direction), after firstremoving a 1 m 1 yd length. For fabric components offabricated systems use the entire system.8. Test Specimens: Selection, Number, and Preparation8.1 Unless

41、otherwise specified, samples should be washedor drycleaned before cutting the test specimens. Conditionsappropriate for the fabric end-use or conditions agreed upon byinterested parties should be used.8.2 Cut four pairs of circular specimens from each swatch inthe laboratory sample with one of each

42、pair of specimens being38 mm 1.5 in. in diameter and the other 140 mm 5.5 in. indiameter.8.3 Take the specimens evenly-spaced across the width ofthe laboratory sample or from two different panels in agarment. Specimens should be staggered in such a manner thatno specimens contain the same yarns. Avo

43、id areas withwrinkles and other distortions. Unless otherwise specified, donot cut specimens nearer the selvage less than110 of the widthof the fabric.9. Preparation of Apparatus9.1 Maintenance CheckFollow instruction manual forproper maintenance of apparatus.10. Conditioning10.1 Condition specimens

44、 in the standard atmosphere fortesting textiles, which is 21 6 1C 70 6 2F and 65 % RH62 % relative humidity for at least 4 h prior to testing.11. Procedure11.1 Make all tests in the standard atmosphere for testingtextiles.11.2 Mount one 140-mm 5.5-in. diameter of standard feltand one fabric specimen

45、 on each table (see Fig. 1). Place one38-mm 1.5-in. diameter disk of 3-mm polyurethane foam anda specimen of the same fabric in each of the holders, makingsure the face of the fabric is exposed for both specimens.11.3 Place the specimen holders on the same table as theother fabric specimen and inser

46、t a spindle into each specimenTABLE 1 Viewing Apparatus and OptionsApparatus Specimen PreparationASTM Lightbox (Fig. 2)A0.78 rad 45LightboxB0.78 rad 45LightboxBflatLightboxBcritical angleAs determined by the buyer and supplierAThe source of supply of the viewing apparatus known to the committee at t

47、histime is Standard Scientific Supply Co., 601 West Market Street, Bethlehem, PA180185208. If you are aware of alternate suppliers, please provide this informa-tion to ASTM Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee, which you ma

48、y attend.BAvailable commercially.D4970/D4970M 1633holder to give a pressure on the larger specimen of approxi-mately 3 kPa 0.44 psi. This pressure is the same as any othersetup but without additional weights.11.4 Start the machine and allow it to run for 100 move-ments. Run additional movements in i

49、ncrements of 100 up to1000 movements as directed in a material specification orcontract. Rate the specimen at each specified interval asdirected in Section 12 and record the final rating.12. Evaluation12.1 Place the 38-mm 1.5-in. disk specimen squarely onthe double-faced tape in the viewing cabinet (see Fig. 2).12.1.1 Using the viewing apparatus and option selectedfrom Table 1 and either suitable fabric or photographicstandards, subjectively rate the face of each specimen incomparison to the original specimen,

展开阅读全文
相关资源
猜你喜欢
  • ANSI UL 83-2017 UL Standard for Safety Thermoplastic-Insulated Wires and Cables (Sixteenth Edition).pdf ANSI UL 83-2017 UL Standard for Safety Thermoplastic-Insulated Wires and Cables (Sixteenth Edition).pdf
  • ANSI UL 834-2004 UL Standard for Safety Heating Water Supply and Power Boilers C Electric (Fifth Edition Reprint with revisions through and including January 10 2018)《电加热供水动力锅炉》.pdf ANSI UL 834-2004 UL Standard for Safety Heating Water Supply and Power Boilers C Electric (Fifth Edition Reprint with revisions through and including January 10 2018)《电加热供水动力锅炉》.pdf
  • ANSI UL 83A-2016 UL Standard for Safety Flouropolymer Insulated Wire (First Edition).pdf ANSI UL 83A-2016 UL Standard for Safety Flouropolymer Insulated Wire (First Edition).pdf
  • ANSI UL 840-2005 UL Standard for Safety Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment (Third Edition Reprint with Revisions Through a.pdf ANSI UL 840-2005 UL Standard for Safety Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment (Third Edition Reprint with Revisions Through a.pdf
  • ANSI UL 842A-2015 UL Standard for Safety Valves for Gasoline and Gasoline Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0 C E85) (First Edition Reprint with.pdf ANSI UL 842A-2015 UL Standard for Safety Valves for Gasoline and Gasoline Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0 C E85) (First Edition Reprint with.pdf
  • ANSI UL 842B-2015 UL Standard for Safety Valves for Diesel Fuel Biodiesel Fuel Diesel Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20) Kerosene and Fue.pdf ANSI UL 842B-2015 UL Standard for Safety Valves for Diesel Fuel Biodiesel Fuel Diesel Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20) Kerosene and Fue.pdf
  • ANSI UL 844-2012 UL Standard for Safety Luminaires for Use in Hazardous (Classified) Locations (Thirteenth Edition Reprint with Revisions Through and Including October 6 2017)《分类危险.pdf ANSI UL 844-2012 UL Standard for Safety Luminaires for Use in Hazardous (Classified) Locations (Thirteenth Edition Reprint with Revisions Through and Including October 6 2017)《分类危险.pdf
  • ANSI UL 845-2005 UL Standard for Safety Motor Control Centers (Fifth Edition Reprint with Revisions Through and Including July 15 2011)《电动机控制台标准(公告日期2004年8月19日)》.pdf ANSI UL 845-2005 UL Standard for Safety Motor Control Centers (Fifth Edition Reprint with Revisions Through and Including July 15 2011)《电动机控制台标准(公告日期2004年8月19日)》.pdf
  • ANSI UL 852-2008 UL Standard for Safety Metallic Sprinkler Pipe for Fire Protection Service (Second Edition Reprint with Revisions Through and Including November 17 2014)《消防服务用金属喷水.pdf ANSI UL 852-2008 UL Standard for Safety Metallic Sprinkler Pipe for Fire Protection Service (Second Edition Reprint with Revisions Through and Including November 17 2014)《消防服务用金属喷水.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1