ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf

上传人:Iclinic170 文档编号:519634 上传时间:2018-12-03 格式:PDF 页数:5 大小:83.65KB
下载 相关 举报
ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf_第1页
第1页 / 共5页
ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf_第2页
第2页 / 共5页
ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf_第3页
第3页 / 共5页
ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf_第4页
第4页 / 共5页
ASTM D5380-1993(2009) Standard Test Method for Identification of Crystalline Pigments and Extenders in Paint by X-Ray Diffraction Analysis《用X射线绕射分析识别涂料中结晶颜料和填充剂的标准试验方法》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 5380 93 (Reapproved 2009)Standard Test Method forIdentification of Crystalline Pigments and Extenders in Paintby X-Ray Diffraction Analysis1This standard is issued under the fixed designation D 5380; the number immediately following the designation indicates the year oforiginal adopti

2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the identification of crystallinepigments and exte

3、nders in liquid paint and dry paint film. It isapplicable to both water-reducible and solvent-reducible paint.It also may be used to identify pigment and extender in grindpaste or alone as dry powder. It is not applicable to amorphouscomponents such as carbon black, amorphous silica, or highlyproces

4、sed clay.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to estab

5、lish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 6.2. Referenced Documents2.1 ASTM Standards:2D 3925 Practice for Sampling Liquid Paints and RelatedPigmented Coatings3. Summary of Tes

6、t Method3.1 Every crystalline substance, in this case pigment orextender, has a characteristic X-ray diffraction pattern.Whether the substance is present alone or in a mixture, itproduces its pattern independently and can be identified by it.An X-ray diffraction pattern of a sample is recorded. Each

7、crystalline substance in the sample is identified by the Ha-nawalt or Fink method or other systematic procedure based oncomparison of the diffraction pattern of the sample withreference patterns of standards.3,4,54. Significance and Use4.1 The choice of pigments and extenders influences theappearanc

8、e, durability, cost, and other properties of paint. Thistest method is a convenient way, and probably the mostreliable, to identify pigments in paint.5. Apparatus5.1 X-ray Diffractometer, suitable for collecting intensityversus two theta (20) angle diffraction patterns in the rangefrom 5 to 65 20. I

9、t is preferred that the diffractometer beequipped with a copper target X-ray tube and a monochromatorthat passes only copper K-alpha radiation. If a monochromatoris not available, then a suitable filter may be used to removecopper K-beta radiation from the diffracted X-ray beam. Anickel filter may b

10、e used for this purpose when a copper targettube is employed.NOTE 1Follow the recommendations of the manufacturer of thediffractometer used.5.2 Liquid Paint or Grind Paste:5.2.1 Paint Shaker.5.2.2 Film Applicator, that will produce a 3- to 10-mil (75-to 250 m) wet film thickness.5.2.3 Plastic Sheet,

11、 such as polyester film, that contains nocrystalline components that would produce interfering X-raydiffraction peaks and is not attacked by paint solvent.5.2.4 Perforated Suction Plate or other flat surface.5.3 Paint Chips or Pigment Powder:5.3.1 Miniature Reciprocating Ball Mill.5.3.2 Stainless St

12、eel Vials, with agitator for ball mill.5.3.3 Powder Specimen Holders, for X-ray diffractometer.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Pai

13、nts and Paint Materials.Current edition approved Feb. 1, 2009. Published February 2009. Originallyapproved in 1993. Last previous edition approved in 2003 as D 5280 - 93 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F

14、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Search Manual, (Hanawalt), “ Inorganic Phases,” International Centre forDiffraction Data, (ICDD), Catalog No. HA 42, Newtown Square Corporate Campus,12 Campus Blvd., Newtown Square, P

15、A 19073-3273.4Search Manual, (Fink), “ Inorganic Phases,” ICDD.5“Powder Diffraction File, Inorganic,” ICDD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Hazards6.1 PrecautionAs exposure to excessive quantities ofX-radiation is i

16、njurious to health, X-ray producing equipmentcan be dangerous to both the operator and persons in theimmediate vicinity unless safety precautions are strictly ob-served. Therefore, users should avoid exposing any parts oftheir bodies, not only to the direct beam, but also to secondaryor scattered ra

17、diation that occurs when an X-ray beam strikesor passes through any material. It is strongly recommended thatusers check the degree of exposure by film carried on them orby the use of dosimeters and that blood counts be madeperiodically. Before utilizing the equipment, all persons desig-nated or aut

18、horized to operate X-ray instrumentation or super-vise its operation, should have a full understanding of its natureand should also become familiar with established safe exposurefactors by a careful study of the NIST handbook,6“X-rayRecommendations of the International Roentgen Ray Commit-tee on X-r

19、ay Protection,” the manufacturers instructionmanual, and other standard publications on the subject. Inquir-ies should be made of state agencies as to existing require-ments.7. Specimen Preparation7.1 Prepare a specimen from the sample using one of thefollowing methods:7.1.1 Liquid Paint or Pigment

20、Paste Thoroughly mix andsample the paint or paste in accordance with Practice D 3925.Place a plastic sheet on the perforated suction plate. On thesheet make a drawdown of the sample. A wet film thickness of3.0 to 10.0 mil (75 to 250 m) is suggested. Cut from thedrawdown on the plastic sheet a specim

21、en of shape and sizesuitable for the mounting in the specimen holder of thediffractometer.7.1.2 Paint ChipUsing a ball mill, grind to a powder thepaint chip or, if it contains more than one layer, the part of thechip of interest. Prepare sufficient specimen to fill the specimenholder or to satisfy t

22、he requirements of the preparation tech-nique to be used. In cases where the chip has a planar surfaceand uniform thickness, it may be possible to cut the chip to therequired dimensions and mount it directly in the specimenholder with no preparation.NOTE 2X-ray diffraction patterns collected for spe

23、cimens consistingof whole chips will reveal the composition of all paint layers probed by theX-rays. The depth probed will depend upon the wavelength of X-ray used,the composition of the paint layer or layers through which the X-rays pass,the composition of the deepest layer probed, the two-theta an

24、gle, and otherfactors. When a copper X-ray tube is used, the depth probed may rangefrom as little as approximately 2 mils (75 m) in the case of very highdensity coatings to as much as 197 mils (0.5 cm) in the case ofunpigmented resin.7.1.3 Paint Film on PanelCut from the panel a specimenof dimension

25、s suitable for mounting in the specimen holder.Asan alternative, it may be convenient to cut a piece of specimento the same dimensions as the specimen holder and use thespecimen without the holder.NOTE 3An X-ray diffraction pattern collected for coating on a panelwill be a superposition of the diffr

26、action patterns of the crystallinecomponents in the coating on the panel and, to the extent that X-raysdiffracted from the substrate reach the detector, the diffraction pattern ofthe substrate.7.2 Mount the specimen in the specimen holder, taking careto insure that the surface of the specimen is flu

27、sh with theoptical plane of the holder.NOTE 4Failure to place the specimen surface in the optical planeilluminated by the X-ray source and viewed by the detector will result ina systematic shift from the correct position of peaks in the observeddiffractogram. The greater the shift, the greater the d

28、ifficulty in using theobserved diffractogram to identify components in the specimen.8. Procedure8.1 Experimental:8.1.1 Turn on the diffractometer and allow it to stabilizethoroughly before beginning collection of results. With the aidof the manufacturers literature, select instrument operationcondit

29、ions that permit collection of X-ray diffractogramsspanning the two-theta range from 5 to 65. The conditionschosen must be suitable for qualitative analysis of a multicom-ponent mixture assuming the presence of a minor componentpresent at approximately one percent by weight. Resultscollected must be

30、 available as the d-spacing and intensity,preferably the integrated intensity, of each peak. In the case ofdiffractometers not equipped with a computer, the two-thetaand intensity data must be measured manually from plotteddiffraction patterns and the d-spacings then calculated from thetwo-theta ang

31、les of the peaks. In the latter case, the diffractionpatterns must be plotted with two-theta scale expansion thatpermits the angle of each peak to be measured to the nearest0.01 Afor peaks in the range above 3.5 Aand to the nearest0.001 Afor peaks below approximately 3.5 A.NOTE 5If not already estab

32、lished, then make sure that the two-thetacalibration of the goniometer of the diffractometer is verified at two ormore angles in accordance with recommendations of the manufacturer andcorrected as needed. The procedure will entail comparison of the observedand expected d-spacing of diffraction peaks

33、 of highly crystalline referencematerials at least at one high and one low two-theta angle.8.1.2 For each sample correct the diffraction pattern span-ning at least from 5 to 65 two-theta.9. Identification9.1 Prepare a list of all diffraction peaks exhibited by thesample including both the d-spacing

34、and intensity (preferablyintegrated intensity) of each peak, listed in decreasing order ofd-spacing. The d-spacing of each peak should be stated at thenearest hundredth of an angstrom for d-spacings greater than3.5 Aand stated to the nearest thousandth of an angstrom ford-values of less than about 3

35、.5 A.9.2 Identify the crystalline phase or phases that account forall peaks in the diffraction pattern of the sample under analysis,using the Hanawalt Method, Fink Method, or other systematicprocedure. Full identification of the crystalline componentsmay be speeded by use of information about compon

36、entsknown to be or suspected of being in the sample (that is,preconceived composition) or by use of the list of commonpigments and extenders appended (see Table 1).6NIST Handbook, X-Ray Recommendations for the International Roentgen RayCommittee on X-Ray Protection, NIST, Gaithersburg, MD, 20899.D 5

37、380 93 (2009)29.2.1 Verification of Preconceived Components:9.2.1.1 Prepare a list of components known to be present orsuspected of being present on the basis of other information, ifany, available to the user. Use the ICDDAlphabetical Index7orother compilation of diffraction peak data to determine

38、thed-values of the three strongest peaks of a suspected component.Compare the three peaks for the suspected component listed inthe Alphabetical Index with the set of diffraction peaksobserved for the sample under analysis. If any one of the threepeaks is absent from the diffraction pattern of the sa

39、mple, thenthe suspected component is not present in the sample. (Excep-tion: If a component has one or more peaks with relativeintensity much greater than its other peaks and is present at lowconcentration, then it may not be possible to observe its weakerpeaks.) If all three peaks are present, then

40、 make sure that thefile number beside the listed d-values is noted and the full setof diffraction data for the suspected component is inspected inthe Powder Data File.59.2.1.2 Confirmation of the presence of the suspected com-ponent requires that all peaks listed for the suspect in thePowder Diffrac

41、tion File, or other reference source, must bepresent in the diffraction pattern of the sample. Furthermore,the relative intensity of the peaks in the diffraction pattern mustbe similar to the relative intensity of the peaks in the referencepattern when experimental error and possible overlap by peak

42、sof other components are taken into account. Once a componentin the sample is identified, make sure that the corresponding setof peaks is either labeled or crossed off the list of peakobserved for the sample. However, a peak may be left on thelist for further consideration if the observed intensity

43、signifi-cantly exceeds the intensity cited in the reference file, thussuggesting that a peak of another component overlaps the onein question. Repeat the procedure stated in 9.2.1 until allpreconceived components are confirmed or rejected. Unas-signed peaks, if any, remaining on the list prepared in

44、 9.1represent unidentified components in the sample. Identify thesecomponents using one or more of the following methods:NOTE 6When comparing the d-values of observed peaks withd-values of peaks listed in references, allow for reasonable experimental7Alphabetical IndexInorganic Phases, Catalog No. A

45、l42, ICDD.TABLE 1 Common Pigments and Extenders for Paintd-Value and IntensityAName FormulaICDD FileNumber17.6x9.054.4983.5841.5046bentoniteBNa0.3(AlMg)2Si4O1012-219(OH)2H2O10.1x4.4993.6663.36x2.5659micaBKal2Si3AlO10(OH)27-259.34x4.6693.116x2.47671.8704talcBMg3Si4O10(OH)213-5587.63x4.283x3.06582.873

46、52.6854gypsum CaSO42H2O 33-3117.36x4.5653.6682.45171.5317chrysotile-20rcl Mg3Si2O5(OH)425-6457.31x4.5753.6572.2731.5355chrysotile-2Mcl Mg3Si2O5(OH)431-8087.17x4.36664.18653.57982.4955kaoliniteBAl2Si2O5(OH)414-1644.568x9.1264.41023.46032.8537zinc phosphateBZn3(PO4)2H2O 37-4654.18x2.6942.4552.1921.722

47、yellow iron oxide FeO(OH) 29-7134.040x3.13612.84112.48712.4860crystobalite SiO239-14253.52x2.37021.89241.70021.6672anatase TiO221-12723.445x3.31973.103x2.12182.1068barium sulfate BaSO424-10353.39x6.3222.98682.84042.2692chrome orange Pb2(OH)2CrO48-4373.38x2.90352.78752.63231.7553red lead Pb3O48-193.3

48、42x4.25722.45781.81811.5429quartz SiO233-11613.310x3.12982.92691.910381.76425zinc sulfide ZnS 36-14503.28x4.9634.3833.4863.037lead chromate PbCrO48-2093.260x9.7965.77124.25123.1305lead oxide sulfatehydratePb4O3SO4H2O 29-7813.260x3.45283.00662.54362.3085strontium chromate SrCrO415-3563.247x2.48752.18

49、831.68761.6242rutile TiO221-12763.22x4.8934.7233.12x2.6682moly orange Pb(Cr19Mo11)O419-6853.160x3.58383.36762.06861.7615cadmium yellow CdS 6-3143.142x4.57123.49433.17423.1188antimony oxide Sb2O311-6893.030x3.85232.28422.09431.87263calcite CaCO324-272.886x2.19232.01521.80421.7863dolomite CaMg(CO3)211-782.700x3.68432.51971.840641.69415red iron oxide Fe2O333-6642.666x3.63382.480x2.17641.6729chrome oxide green Cr2O36-5042.623x4.4764.2563.6193.299lead carbonatehydroxidePb3(CO3)2(OH)213-1312.609x7.0293.3193.0892.8967zinc yellow K2Zn4(CrO4)23H2O 8-2022.5503x2.8

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1