ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf

上传人:eventdump275 文档编号:520254 上传时间:2018-12-03 格式:PDF 页数:8 大小:143.27KB
下载 相关 举报
ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf_第1页
第1页 / 共8页
ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf_第2页
第2页 / 共8页
ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf_第3页
第3页 / 共8页
ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf_第4页
第4页 / 共8页
ASTM D5614-1994(2014) 4504 Standard Test Method for Open Channel Flow Measurement of Water with Broad-Crested Weirs《采用宽口堰测量明渠水流流量的标准试验方法》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D5614 94 (Reapproved 2014)Standard Test Method forOpen Channel Flow Measurement of Water with Broad-Crested Weirs1This standard is issued under the fixed designation D5614; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio

2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers measurement of the volumetricflow rate of water in open channels with two types

3、 ofhorizontal broad-crested weirs: those having a square (sharp)upstream corner and those having a well-rounded upstreamcorner.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for inform

4、ation onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulator

5、y limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3858 Test Method for Open-Channel Flow Measurementof Water by Velocity-Area Method2.2 IS

6、O Standards:3ISO 555-1973 Liquid Flow Measurement in OpenChannelsDilution Methods for Measurement of SteadyFlowConstant Rate Injection MethodISO 3846-1989 Liquid Flow Measurement in Open Chan-nels by Weirs and FlumesRectangular Broad-CrestedWeirsISO 4373-1979 Measurement of Liquid Flow in OpenChanne

7、lsWater Level Measuring DevicesISO 4374-1990 Liquid Flow Measurement in Open Chan-nels by Weirs and FlumesRound-Nose Horizontal CrestWeirs3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1

8、 boundary layer displacement thickness the bound-ary layer is a layer of fluid flow adjacent to a solid surface (inthis case, the weir crest and sidewalls) in which, due to viscousfriction, the velocity increases from zero at the stationarysurface to an essentially frictionless-flow value at the edg

9、e ofthe layer. The displacement thickness is a distance normal tothe solid surface that the flow streamlines can be considered tohave been displaced by virtue of the boundary-layer informa-tion.3.2.2 crestthe horizontal plane surface of the weir.3.2.3 critical flowopen channel flow in which the ener

10、gy,expressed in terms of depth plus velocity head, is a minimumfor a given flow rate and channel. The Froude number is unityat critical flow.3.2.4 Froude numbera dimensionless number expressingthe ratio of inertial to gravity forces in free surface flow. It isequal to the average velocity divided by

11、 the square root of theproduct of the average depth and the acceleration due togravity.3.2.5 headin this test method , the depth of water above aspecified elevation. The measuring head is the depth of flowabove the weir crest measured at an appropriate locationupstream of the weir; the downstream he

12、ad is referencedsimilarly to the crest elevation and measured downstream ofthe weir. The head plus the corresponding velocity head isoften termed the total head or total energy head.3.2.6 hydraulic jumpan abrupt transition from supercriti-cal flow to subcritical or tranquil flow, accompanied byconsi

13、derable turbulence or gravity waves, or both.3.2.7 nappethe curved sheet or jet of water overfalling thedownstream end of the weir.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.07 on Sediments,Geomorphology, and Open-Ch

14、annel Flow.Current edition approved Jan. 1, 2014. Published March 2014. Originallyapproved in 1994. Last previous edition approved in 2008 as D5614 94 (2008).DOI: 10.1520/D5614-94R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.

15、org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive

16、, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.8 primary devicethe device (in this case, the weir) thatcreates a hydrodynamic condition that can be sensed by thesecondary instrument.3.2.9 Reynolds numbera dimensionless number express-ing the ratio of inertial to viscous forces in

17、 a flow.The pertinentReynolds number on the weir crest is equal to the (critical)velocity multiplied by the crest length and divided by thekinematic viscosity of the water.3.2.10 secondary instrument in this case, a device thatmeasures the depth of flow (referenced to the crest elevation)at an appro

18、priate location upstream of the weir. The secondaryinstrument may also convert this measured head to an indicatedflow rate or could totalize flow rate.3.2.11 stilling wella small free-surface reservoir con-nected through a restricted passage to the head-measurementlocation upstream of the weir so th

19、at a head measurement canbe made under quiescent conditions.3.2.12 subcritical flowopen channel flow that is deeperand at lower velocity than critical flow for the same flow rate;sometimes called tranquil flow.AFroude number less than oneexists.3.2.13 submergencea condition in which the water levelo

20、n the downstream side of the weir is high enough to affect theflow over the weir and hence alter the head-discharge relation.It is usually expressed as a ratio or percentage of downstreamto upstream head or downstream to upstream total head.3.2.14 supercritical flowopen channel flow that is shal-low

21、er and at higher velocity than critical flow for the same flowrate. A Froude number greater than one exists.3.2.15 tailwaterthe water elevation immediately down-stream of the weir.3.2.16 tranquil flowsee subcritical flow.3.2.17 velocity headthe square of the average velocitydivided by twice the acce

22、leration due to gravity.4. Summary of Test Method4.1 In broad-crested weirs, the length of the horizontal crestin the direction of flow is large enough relative to the upstreamhead for essentially rectilinear critical flow to occur at somepoint along the crest. This ideally permits the flow rate to

23、beobtained from a single measurement of the upstream head; acorrective coefficient must be applied in practice. This coeffi-cient has been evaluated experimentally for square-edge weirsand can be determined analytically for rounded weirs.5. Significance and Use5.1 Broad-crested weirs can be used for

24、 accurate measure-ments of a wide range of flow rates, but their structuralsimplicity and sturdiness make them particularly useful formeasuring large flows under field conditions.5.2 Because they require vertical sidewalls, broad-crestedweirs are particularly adaptable to rectangular artificial chan

25、-nels or to natural and artificial channels that can readily belined with vertical sidewalls in the immediate vicinity of theweir.6. Interferences6.1 Broad-crested weirs are not suitable for use in sediment-laden streams that are carrying heavy bed loads. However,floating debris is readily passed, p

26、articularly by the roundedweir (see 7.2.1).6.2 Broad-crested weirs cannot be used beyond submer-gence limits because insufficient data exist to document theirperformance. It is therefore necessary to adhere to thetailwater-level limitations described in this test method.7. Apparatus7.1 A broad-crest

27、ed weir measuring system consists of theweir itself and its immediate channel (the primary) and a headmeasuring device (the secondary). The secondary device canrange from a simple staff gage for visual readings to aninstrument that senses the depth continuously, converts it to aflow rate, and displa

28、ys or transmits a readout or record of theinstantaneous flow rate or totalized flow, or both.7.2 Square-Edge (Rectangular) Broad-Crested Weir:7.2.1 ConfigurationThe square-edge broad-crested weiras shown in Fig. 1 is rectangular in longitudinal profile andprovides a plane horizontal crest that has f

29、inite length in thedirection of flow and extends the full width of the channelbetween vertical sidewalls. A contracted section must beconstructed as shown (see also 7.4.1.2) if the channel does nothave vertical sidewalls or is wider than the desired crest. Thevertical sidewalls must extend downstrea

30、m of the downstreamface of the weir a distance of at least twice the maximum head.Recommended limits on dimensions and geometric ratios aregiven in 7.2.5. The upstream and downstream faces must bevertical and perpendicular to the channel surfaces, and it isimportant that the upstream corner be squar

31、e and sharp.NOTE 1High flow rates combined with floating debris may damagethe sharp edge; rounded-edge weirs should be considered for suchapplications.7.2.2 Construction Requirements:7.2.2.1 The structure must be sturdy enough to withstandthe maximum flow rate and must be watertight so that nomeasur

32、able leakage can bypass it.7.2.2.2 FinishLarge weirs constructed in the field shouldhave a finish equivalent to that of smooth concrete. Smallerweirs, such as those in a laboratory environment, should havea smoothness equivalent to that of rolled sheet metal.7.2.2.3 LevelThe crest must not deviate f

33、rom a level planeby more than 0.01 ft (2 mm) at any point or exceed a slope of0.01 anywhere.7.2.3 Head Measurement LocationMake the head mea-surement at a distance of 3 h to 4 hmaxupstream of theupstream face of the weir, where hmaxis the anticipatedmaximum head.7.2.4 Head-Discharge Relations:7.2.4.

34、1 Basic EquationsThe basic relation for the flowrate, Q, over a broad-crested weir is, in compatible units,Q 5 2/3!3/2g1/2CvCdBh3/2(1)D5614 94 (2014)2where:h = measured upstream head referenced to the crestelevation,B = width of the weir between the vertical side-walls,g = acceleration due to gravit

35、y,Cd= discharge coefficient that accounts for departures fromideal conditions, andCv= velocity-of-approach coefficient that permits the flowrate to be related to the measured head rather than thetotal head, H. Then,Cv5 H/h!3/25 h1V2u/2g!/h#3/2(2)where:Vu= average velocity at the head-measurement loc

36、ation,and = coefficient that accounts for any increase in the kineticenergy term caused by a nonuniform velocity distribu-tion. However, in this test method, the approachvelocity is considered sufficiently close to uniform (see7.4.1) for to be essentially unity.7.2.4.2 In the case of square-edge wei

37、rs, both Cdand Cvareaffected by the head-to-weir height ratio, h/P, so it is conve-nient to combine them into a single coefficient, C; then,Q 5 2/3!3/2g1/2CBh3/2(3)7.2.4.3 Discharge Coeffcient, C:(1) The discharge coefficient is given as a function of h/Land h/P in Fig. 2, which has been adapted fro

38、m ISO 3846-1989.(2) The discharge coefficient for h/L 0.3 is constant at0.850, provided that h/P 0.4, the weir is nolonger truly broad crested in accordance with 4.1, since theflow over the crest is curvilinear throughout.)7.2.5 Limiting ConditionsThe flow conditions and dimen-sions of the square-ed

39、ge weir are subject to the followinglimits:(1) h 0.2 ft (0.06 m), or 0.1 L, whichever is larger;(2) B 1 ft (0.3 m);(3) P 0.5 ft (0.15 m);(4) 0.1 h/L 1.6;(5) h/P 1.6; and(6) 0.1 L/P 4.The minimum h is recommended in order to minimize theeffects of surface tension, viscosity, and surface roughness and

40、to avoid small heads that may be difficult to measure accu-rately. The minimum h/L prevents frictional effects fromcausing the point of critical flow to shift away from theupstream end of the crest. The limitation on maximum h/P isintended to reduce the likelihood of upstream disturbances, andthe re

41、maining limitations are recommended mainly to conformto the experiments from which the coefficients were obtained.Limiting values of tailwater depth to avoid submergence aregiven in 7.4.2.2.7.3 Rounded Broad-Crested Weir:7.3.1 Configuration:7.3.1.1 The rounded broad-crested weir is shown in Fig. 3.A

42、s in the square-edge weir, a plane level crest of finitestreamwise length extends over the full channel width betweenvertical sidewalls. If the channel is not rectangular or ofsuitable width, construct a contracted section as shown. Theupstream face must be vertical and perpendicular to theFIG. 1 Sq

43、uare-Edge Broad-Crested WeirD5614 94 (2014)3channel surfaces. However, the following geometric featuresdepart from those of the square-edge weir.7.3.1.2 To prevent separation round the upstream corner toa radius of at least 0.2 Hmax, where Hmaxis the anticipatedmaximum upstream total head.NOTE 2Sour

44、ces customarily express rounded-weir dimensions interms of total head, H. Users can place them in terms of measured head,h, by using (Eq 2) and Table 1.IfH/P is limited to a maximum of 1.5 asrecommended in 7.3.5, H/h will not exceed approximately 1.06.7.3.1.3 The length of the horizontal part of the

45、 crest must beat least 1.75 Hmax, and the total length (including radius) mustbe at least 2.25 Hmax.7.3.1.4 The downstream face of the rounded weir can besloped rather than vertical; the only effect is on the tailwaterdepth necessary to avoid submergence (see 7.4.2.3).7.3.2 Construction Requirements

46、:7.3.2.1 The watertightness and finish requirements for therounded weir are the same as those for the square-edge weirgiven in 7.2.2.1 and 7.2.2.2.7.3.2.2 LevelThe crest of the rounded weir must be levelwithin the slope of 0.001.7.3.3 Head Measurement LocationMeasure the head at adistance of 3 H to

47、4 Hmaxupstream of the upstream face of theweir.7.3.4 Head-Discharge Relations:7.3.4.1 For rounded-edge weirs, the discharge coefficient,Cd,inEq 1 is associated with frictional effects along the crestand may be expressed in terms of boundary layer growth asCd5 1 2 2*/L!L/B!#1 2 */L!L/h!#3/2(4)where:*

48、= boundary-layer displacement thickness.The value of */L as a function of Reynolds number (see3.2.9) and relative surface roughness can be determined bymethods given in ISO 4374-1990 and in fluid mechanics texts;however, unless the surfaces are excessively rough, it issufficiently accurate to use */

49、 L = 0.003 for relatively smalland smooth weirs, as in a laboratory, and */ L = 0.004 forlarger concrete weirs.7.3.4.2 The velocity-of-approach coefficient, Cv,inEq 1 isgiven in Table 1 as a function of CdBh/Au, where Auis thecross-sectional area of the approach flow and is equal toB(P + h).7.3.5 Limiting ConditionsThe flow conditions and dimen-sions of the rounded weir are subject to the following limita-tions:(1) h 0.2 ft (0.06 m);(2) 0.05 H/L 0.57;(3) H/P 1.5;(4) 0.5 ft (0.15 m); andFIG. 2 Discharge Coefficients

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1