1、Designation: D 5678 95 (Reapproved 2008)Standard Test Method forFreeze/Thaw Resistance of Wax Emulsion Floor Polish1This standard is issued under the fixed designation D 5678; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea

2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the stabil-ity of wax emulsion floor polishes when these are expose

3、d torepeated cycles of freezing and thawing. Possible degradationof the emulsion is observed and possible reduction of initialgloss is measured.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purp

4、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1

5、436 Test Methods for Application of Emulsion FloorPolishes to Substrates for Testing PurposesD 1455 Test Method for 60 Specular Gloss of EmulsionFloor Polish3. Significance and Use3.1 This test method is used to determine the effect offreezing on wax emulsion floor polishes. It may be used topredict

6、 the stability of a floor polish in transit or when exposedto freezing, and whether or not the polish is damaged byfreezing.4. Apparatus4.1 Freezer, adjusted to 7.8 to 6.7C (18 to 20F).4.2 Clear Bottles, three, 4 oz (125 mL) capacity.4.3 Test Flooring SubstratesOffcial Vinyl Composition Tile(OVCT),3

7、black, 304.8 mm (12 by 12 in.).4.4 60-Deg Gloss Meter.4.5 Polishes, to be tested.5. Procedure5.1 Determine the turbidity of each polish, visually or byany other suitable method.5.2 Apply one coat of each test polish on a black vinylcomposition tile using pour method (E) (see Test MethodD 1436). Allo

8、w polish to dry in a vertical position at roomtemperature. After polish is dry, wait 1 h, then buff with a softcotton cloth. Determine the initial gloss in accordance withTest Method D 1455.5.3 Place 100 mL of polish in each of three 125 mL (4 oz)clear bottles. Place the filled bottles side by side,

9、 horizontally,in the freezer on a rack. Provide a minimum of 25 mm (1 in.)between the bottles and the freezer walls and keep the contactarea between the bottles and the rack to a minimum.5.4 Allow the samples to remain in the freezer for 16 h, ora minimum of 8 h after becoming solid.5.5 Remove all t

10、he samples of frozen polish and allow tothaw, undisturbed, at 18 to 24C (65 to 76F) for a period of 24h.5.6 Inspect all thawed samples visually. Observe and recordany separation or stratification without disturbing the sample.5.7 Mix one bottle of the thawed polish by inverting it tentimes. Then app

11、ly one coat of polish on a black vinylcomposition tile using the same procedure as in 5.2. Allowpolish to dry in a vertical position at room temperature. Afterpolish is dry, wait 1 h, then buff with a soft cotton cloth.Determine the gloss in accordance with Test Method D 1455.Also determine and reco

12、rd while applying the polish if thisagitated sample is a free flowing liquid, or has separated, or haslarge particles that cannot be buffed.5.8 Determine the turbidity on the open sample of polish asin 5.1.5.9 Return the remaining two bottles of polish to the freezerfor 16 h, and repeat 5.4-5.8 for

13、the second freeze/thaw cycle.5.10 Return the third bottle of polish to the freezer for 16 hand again repeat 5.4-5.8.6. Interpretation of Results6.1 The polish passes each freeze/thaw cycle after mixing ifthere has been no meaningful change in appearance, forexample, separation, large particles, not

14、being a free flowing1This test method is under the jurisdiction ofASTM Committee D21 on Polishesand is the direct responsibility of Subcommittee D21.03 on Chemical and PhysicalTesting.Current edition approved March 1, 2008. Published April 2008. Originallyapproved in 1995. Last previous edition appr

15、oved in 2002 as D 5678 - 95(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Chemical Sp

16、ecialties Manufacturers Assn., 1913 I St., NW,Washington, DC 20006.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.liquid, or anything else that would prevent its application anduse as a floor polish. The polish also passes each free

17、ze/thawcycle if there is no more than a 25 % loss in gloss. Gloss isdetermined as in 5.2.7. Report7.1 Report test results as the number of cycles passedtogether with visual inspection comments regarding possibleseparation, stratification, and pourability.8. Precision and Bias8.1 PrecisionThe test me

18、thod differentiates polishes thatare freeze stable from those that are not. Polishes that areborderline in freeze/thaw stability may pass in some laborato-ries and fail in others.8.2 BiasThis test method has no bias because the resultsdeveloped are defined only in terms of this test method.9. Keywor

19、ds9.1 floor polish; freeze/thaw; wax emulsionASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, an

20、d the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revisi

21、on of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you sh

22、ouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 5678 95 (2008)2