ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf

上传人:ownview251 文档编号:520893 上传时间:2018-12-03 格式:PDF 页数:7 大小:129.83KB
下载 相关 举报
ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf_第1页
第1页 / 共7页
ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf_第2页
第2页 / 共7页
ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf_第3页
第3页 / 共7页
ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf_第4页
第4页 / 共7页
ASTM D5863-2000a(2016) 3767 Standard Test Methods for Determination of Nickel Vanadium Iron and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry《使用火焰.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D5863 00a (Reapproved 2016)Standard Test Methods forDetermination of Nickel, Vanadium, Iron, and Sodium inCrude Oils and Residual Fuels by Flame Atomic AbsorptionSpectrometry1This standard is issued under the fixed designation D5863; the number immediately following the designation indi

2、cates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination

3、 of nickel,vanadium, iron, and sodium in crude oils and residual fuels byflame atomic absorption spectrometry (AAS). Two differenttest methods are presented.1.2 Test Method A, Sections 713Flame AAS is used toanalyze a sample that is decomposed with acid for thedetermination of total Ni, V, and Fe.1.

4、3 Test Method B, Sections 1419Flame AAS is used toanalyze a sample diluted with an organic solvent for thedetermination of Ni, V, and Na. This test method uses oil-soluble metals for calibration to determine dissolved metalsand does not purport to quantitatively determine nor detectinsoluble particu

5、lates. Hence, this test method may underesti-mate the metal content, especially sodium, present as inorganicsodium salts.1.4 The concentration ranges covered by these test methodsare determined by the sensitivity of the instruments, theamount of sample taken for analysis, and the dilution volume.A s

6、pecific statement is given in Note 1.1.5 For each element, each test method has its own uniqueprecision. The user can select the appropriate test method basedon the precision required for the specific analysis.1.6 The values stated in SI units are to be regarded asstandard. No other units of measure

7、ment are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita

8、tions prior to use. Specific warningstatements are given in 7.1, 8.2, 8.5, 10.2, 10.4, and 15.1.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andP

9、etroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System Performance3. Summary of Test Method3.1 Test Method AOne to twenty grams of sample areweighed into a beaker and decomposed with concentratedsulfuric acid

10、 by heating to dryness. The residual carbon isburned off by heating at 525 C in a muffle furnace. Theinorganic residue is digested in dilute nitric acid, evaporated toincipient dryness, dissolved in dilute nitric and made up tovolume with dilute nitric acid. Interference suppressant isadded to the d

11、ilute nitric acid solution. The solution isnebulized into the flame of an atomic absorption spectrometer.A nitrous oxide/acetylene flame is used for vanadium and anair/acetylene flame is used for nickel and iron. The instrumentis calibrated with matrix-matched standard solutions. Themeasured absorpt

12、ion intensities are related to concentrations bythe appropriate use of calibration data.3.2 Test Method BSample is diluted with an organicsolvent to give a test solution containing either 5 % (m/m) or20 % (m/m) sample. The recommended sample concentrationis dependent on the concentrations of the ana

13、lytes in thesample. For the determination of vanadium, interference sup-pressant is added to the test solution. The test solution isnebulized into the flame of an atomic absorption spectrometer.A nitrous oxide/acetylene flame is used for vanadium and an1These test methods are under the jurisdiction

14、of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand are the direct responsibility ofSubcommittee D02.03 on Elemental Analysis.Current edition approved April 1, 2016. Published May 2016. Originallyapproved in 1995. Last previous edition approved in 2011 as D5863 00a (2011).DOI

15、: 10.1520/D5863-00AR16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr

16、 Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1air/acetylene flame is used for nickel and sodium. The mea-sured absorption intensities are related to concentrations by theappropriate use of calibration data.4. Significance and Use4.1 When fuels are combusted, metals pres

17、ent in the fuelscan form low melting compounds that are corrosive to metalparts. Metals present at trace levels in petroleum can deactivatecatalysts during processing. These test methods provide ameans of quantitatively determining the concentrations ofvanadium, nickel, iron, and sodium. Thus, these

18、 test methodscan be used to aid in determining the quality and value of thecrude oil and residual oil.5. Purity of Reagents5.1 Reagent grade chemicals shall be used for all tests.Unless otherwise indicated, it is intended that all reagentsconform to the specifications of the Committee on AnalyticalR

19、eagents of the American Chemical Society where suchspecifications are available.3Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.5.2 When determining metals at concentratio

20、ns less than1 mg kg, use ultra-pure grade reagents.5.3 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean reagent water conformingto Type II of Specification D1193.6. Sampling and Sample Handling6.1 The objective of sampling is to obtain a sample fortesting purp

21、oses that is representative of the entire quantity.Only representative samples obtained as specified in PracticesD4057 and D4177 shall be used. Do not fill the samplecontainer more than two-thirds full6.2 Prior to weighing, stir the sample and then shake thesample in its container. If the sample doe

22、s not readily flow atroom temperature, heat the sample to a sufficiently high andsafe temperature to ensure adequate fluidity.TEST METHOD AFLAME ATOMIC ABSORPTIONAFTER ACID DECOMPOSITION OF THE SAMPLE7. Apparatus7.1 Atomic Absorption Spectrometer, complete instrumentwith hollow cathode lamps and bur

23、ners with gas supplies tosupport air-acetylene and nitrous oxide-acetylene flames.(WarningHazardous. Potentially toxic and explosive. Referto the manufacturers instrument manual for associated safetyhazards.)7.2 Sample Decomposition Apparatus (optional)This ap-paratus is described in Fig. 1. It cons

24、ists of a borosilicate glass400 mL beaker for the test solution, an air bath (Fig. 2) thatrests on a hot plate and a 250 W infrared lamp supported2.5 cm above the air bath. A variable transformer controls thevoltage applied to the lamp.7.3 GlasswareBorosilicate glass 400 mL beakers, volu-metric flas

25、ks of various capacities and pipettes of variouscapacities. When determining concentrations below 1 mg kg,all glassware must be thoroughly cleaned (or soaked overnight)with 5 % HNO3and rinsed five times with water.7.4 Electric Muffle Furnace, capable of maintaining 525 C6 25 C and sufficiently large

26、 to accommodate 400 mL bea-kers. The capability of an oxygen bleed is advantageous andoptional.7.5 Steam Bath.7.6 Temperature Controlled Hot Plate, (optional).7.7 Drying Oven, (optional), explosion-proof, if used to heatcrude oils to obtain fluidity.8. Reagents8.1 Aqueous Standard SolutionsIndividua

27、l aqueous stan-dards with 1000 mg kg concentrations of vanadium, nickel,and iron, purchased or prepared in acid matrix to ensurestability.8.2 Nitric AcidConcentrated nitric acid, HNO3.(WarningPoison, oxidizer. Causes severe burns. Harmful orfatal if swallowed or inhaled.)8.3 Nitric Acid 50 % (V/V)Ca

28、refully add, with stirring,one volume of concentrated nitric acid to one volume of water.8.4 Dilute Nitric Acid, 5 % (V/V)Carefully add, withstirring, one volume of concentrated nitric acid to 19 volumesof water.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society,

29、Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.FIG.

30、1 Decomposition ApparatusD5863 00a (2016)28.5 Sulfuric AcidConcentrated sulfuric acid, H2SO4.(WarningPoison, oxidizer. Causes severe burns. Harmful orfatal if swallowed or inhaled.)8.6 Aluminum Nitrate, Al(NO3)39HOH.8.7 Potassium Nitrate, KNO3.9. Preparation of Standards9.1 Multi-Element StandardUsi

31、ng the aqueous standardsolutions, prepare a multi-element standard containing100 mg kg each of vanadium, nickel, and iron. Standardsshould be prepared to ensure accuracy and stability and shouldbe stored in clean containers to safeguard against physicaldegradation.9.2 Working StandardsPrepare at lea

32、st two working stan-dards to cover the concentration ranges specified in Table 1.For vanadium, add the specified interference suppressant. Eachworking standard must contain 5 % (V V) nitric acid. Stan-dards should be prepared to ensure accuracy and stability andshould be stored in clean containers t

33、o safeguard againstphysical degradation.9.3 Standard Blank, the standard blank contains 5 % (V/V)nitric acid and any interference suppressant specified in Table1.9.4 Check StandardPrepare a calibration check standardin the same way as the working standards and at analyteconcentrations that are typic

34、al of the specimens being ana-lyzed.10. Preparation of Test Solutions10.1 Into a beaker, weigh an amount of sample estimated tocontain between 0.0025 mg and 0.12 mg of each metal to bedetermined. A typical mass is 10 g. Add 0.5 mL of H2SO4foreach gram of sample.NOTE 1If it is desired to extend the l

35、ower concentration limits of thetest method, it is recommended that the decomposition be done in 10 gincrements up to a maximum of 100 g. It is not necessary to destroy all theorganic matter each time before adding additional amounts of the sampleand acid. When it is desired to determine higher conc

36、entrations, reduce thesample size accordingly.10.2 At the same time prepare reagent blanks using thesame amount of sulfuric acid as used for sample decomposi-tion. Reagent blanks should be carried through the sameprocedure as the samples. (WarningReagent blanks arecritical when determining concentra

37、tions below 1 mg kg. Tosimplify the analysis, use the same volume of acid and thesame dilutions as used for the samples. For example, if 20 g ofsample is being decomposed, use 10 mL of sulfuric acid for thereagent blank.)10.3 The use of the air bath apparatus (Fig. 2) is optional.Place the beaker in

38、 the air bath, which is located in the hood.The hot plate is off at this time. Heat gently from the top withthe infrared lamp (Fig. 1) while stirring the test solution with aglass rod. As decomposition proceeds (indicated by a frothingand foaming), control the heat of the infrared lamp to maintainst

39、eady evolution of fumes. Give constant attention to eachsample mixture until all risk of spattering and foaming is past.Then, gradually increase the temperature of both the hot plateand lamp until the sample is reduced to a carbonaceous ash.10.4 If the air bath apparatus is not used, heat the sample

40、and acid on a temperature controlled hot plate. As described in10.3, monitor the decomposition reaction and adjust thetemperature of the hot plate accordingly. (WarningHotfuming concentrated sulfuric acid is very corrosive and astrong oxidizing acid. The analyst should work in a well-ventilated hood

41、 and wear rubber gloves and a suitable faceshield to protect against spattering acid.)NOTE 1All parts 16 gage (1.5 mm, 0.060 in.) aluminum. All dimen-sions are in inches.Metric Equivalentsin. mm in. mm1 25.4 378 98.4112 38.1 5 1272 50.8 612 165.13116 77.8 . .FIG. 2 Air BathTABLE 1 AAS Conditions for

42、 the Determination of Vanadium,Nickel, and Iron Following Acid Sample DecompositionElementWavelength,nmConcentrationRange, g/mLInterferenceSuppressantFlameVanadium 318.4 0.520 250 g/mL Al,Al(NO3)3in 5 %(V/V)HNO3N2O-C2H2Nickel 232.0 0.520 None Air-C2H2Iron 248.3 3.010 None Air-C2H2D5863 00a (2016)310

43、.5 Place the sample in the muffle furnace maintained at525 C 6 25 C. Optionally, introduce a gentle stream ofoxygen into the furnace to expedite oxidation. Continue to heatuntil the carbon is completely removed.10.6 Dissolve the inorganic residue by washing down thewall of the beaker with about 10 m

44、L of the 1 + 1 HNO3. Digeston a steam bath for 15 min to 30 min. Transfer to a hot plateand gently evaporate to incipient dryness.10.7 Wash down the wall of the beaker with about 10 mL ofdilute nitric acid (5 % V/V). Digest on the steam bath until allsalts are dissolved. Allow to cool. Transfer quan

45、titatively to avolumetric flask of suitable volume and make up to volumewith dilute nitric acid. This is the test solution.10.8 Pipette aliquots of the test solution into two separatevolumetric flasks. Retain one flask for the determination ofnickel and iron. To the other flask add aluminum interfer

46、encesuppressant for vanadium determination (refer to Table 1) anddilute up to mark with dilute nitric acid (5 % V/V). Similarly,prepare a reagent blank solution for vanadium analysis.11. Preparation of Apparatus11.1 Consult the manufacturers instructions for the opera-tion of the atomic absorption s

47、pectrometer. This test methodassumes that good operating procedures are followed. Designdifferences between spectrometers make it impractical toexactly specify required instrument settings.11.2 Set up the instrument to determine each analyte se-quentially.12. Calibration and Analysis12.1 For each an

48、alyte in turn, perform the following opera-tion:12.2 Nebulize the appropriate blank standard and zero theinstrument.12.3 Nebulize the working standards, determine the absor-bance and construct a calibration curve of absorbance versusanalyte concentration utilizing the instruments concentrationmode i

49、f available, otherwise plot these values.12.4 Use the check standard to determine if the calibrationfor each analyte is accurate. If the results obtained on the checkstandard are not within 65 % of the expected concentration foreach analyte, take corrective action and repeat the calibration.12.5 Nebulize the test solutions and measure and record theabsorbance. If appropriate, blank correct this absorbance bysubtracting the reagent blank absorbance.12.6 After measuring absorbances for a test solution, checkthe blank standard. If this