ASTM D7047-2012 red 4686 Standard Test Method for Mucilloid Content of Plantago Insularis (Ovata Psyllium)《用作增粘剂的岛生车前 (Ovata 欧车前) 的粘液含量测定的标准试验方法》.pdf

上传人:feelhesitate105 文档编号:524368 上传时间:2018-12-04 格式:PDF 页数:2 大小:16.17KB
下载 相关 举报
ASTM D7047-2012 red 4686 Standard Test Method for Mucilloid Content of Plantago Insularis (Ovata Psyllium)《用作增粘剂的岛生车前 (Ovata 欧车前) 的粘液含量测定的标准试验方法》.pdf_第1页
第1页 / 共2页
ASTM D7047-2012 red 4686 Standard Test Method for Mucilloid Content of Plantago Insularis (Ovata Psyllium)《用作增粘剂的岛生车前 (Ovata 欧车前) 的粘液含量测定的标准试验方法》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D7047 04 D7047 12Standard Test Method forMucilloid Content of Plantago Insularis (Ovata, Psyllium)Used as a Tackifiers1This standard is issued under the fixed designation D7047; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re

2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 QuantitiveQuantitative test method to determine the mucilloid content of plantago insularis (Ovata

3、 Psyllium) used as atackifier.Psyllium).1.2 The purpose of this test method is to provide a means of evaluating the amount of mucilloid in a plantago insularis (Ovata,Psyllium) tackifier.Psyllium).1.3 The values stated in SI units are to be regarded as the standard. The values in parenthesis are pr

4、ovided for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations pr

5、ior to use.2. Terminology2.1 Definitions:2.1.1 For common definitions of terms in this standard refer to Terminology D635.2.1.2 tackifier, nin erosion control, a substance by which its characteristics are used for bonding various types of materialsand/or soil together.3. Summary of Test Method3.1 Pr

6、oduct specimen is taken and weighed, saturated and measured. The mucilloid content is expressed as a percent.4. Significance and Use4.1 The meaning of the test is related to the manufacturing and end use of the material, to determine characteristics of products.5. Apparatus5.1 Electronic Gram Scale

7、or Balance Scale, minimum accuracy 0.0000.1 gms.5.2 Graduated 50.0 mL Glass Cylinder , with ground glass stopper.5.3 Weighting Boat.5.4 60 Minute Timer, graduated in one minute intervals.6. Sampling, Test Specimens, and Test Units6.1 Prepare specimen by separating 3.0 g of plantago insularis (Ovata,

8、 Psyllium) used as a tackifier from an undamaged bagby taking 13 from the top of the bag, 13 from the middle of the bag and 13 from the bottom of the bag.7. Procedure7.1 Weigh weighting boat and place 1.0 g of the plantago insularis (Ovata, Psyllium) used as a tackifier specimen in theweighting boat

9、7.2 Transfer the sample in the weighting boat quantitatively to the graduated cylinder.1 This test method is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.25 on Erosion and SedimentControl Technology.Current edition approved May 1

10、 2004Aug. 1, 2012. Published June 2004October 2012. Originally approved in 2004. Last previous edition approved in 2004 as D704704.DOI: 10.1520/D7047-04.10.1520/D7047-12.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes

11、have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official

12、document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.3 Add 20 mls tap water to the cylinder then close cylinder with glass stopper.7.4 Shake the cylinder vigorously for 1 min.7.5 Set the timer for 60 min and start it, shake the

13、cylinder vigorously for 1 min when the timer indicates the minutes elapsedfor the procedure has reached 9, 19, 29, 39, 49, and 59.7.6 After shaking the cylinder for the final time, allow the cylinder to stand for 23 h.7.7 Record to the nearest ml the column which is a suspended solid.8. Calculation

14、or Interpretation of Results8.1 Calculate the percentage mucilloid as follows:Mucilloid Content%5S/W 3100 (1)where:S = mls of the suspended solid, andW = 20 mls of tap water.9. Report9.1 Report the equation as a percentage.10. Precision and Bias10.1 PrecisionIt is not possible to specify the precisi

15、on of the procedure in D7047 for mucilloid content of plantago insularis(Ovata, Psyllium) used as a tackifier because no material having an accepted reference value is available.10.2 BiasThere is no accepted reference value for this test method, therefore, bias cannot be determined.11. Keywords11.1

16、erosion control; mucilloid; muciloid; ovata; plantago insularis; psyllium; tackifierASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the

17、 validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your

18、 comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments

19、have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multi

20、ple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).D7047 122

展开阅读全文
相关资源
猜你喜欢
  • ASHRAE LO-09-024-2009 Pressurization of Floors to Improve Life Safety During a High-Rise Fire《生命安全在高层建筑防火期间对楼层增压改进》.pdf ASHRAE LO-09-024-2009 Pressurization of Floors to Improve Life Safety During a High-Rise Fire《生命安全在高层建筑防火期间对楼层增压改进》.pdf
  • ASHRAE LO-09-025-2009 Specific Energy Consumption (SEC) for the Integrated Circuit Assembly and Testing (IC A T) Industry in Taiwan《台湾集成电路组件和测试(IC A T)工业用能量消耗率》.pdf ASHRAE LO-09-025-2009 Specific Energy Consumption (SEC) for the Integrated Circuit Assembly and Testing (IC A T) Industry in Taiwan《台湾集成电路组件和测试(IC A T)工业用能量消耗率》.pdf
  • ASHRAE LO-09-026-2009 Humidification of Large-Scale Cleanrooms by Adiabatic Humidification Method in Subtropical Areas An Industrial Case Study《通过绝热增湿法测定亚热带地区大尺度洁净室内的湿润性》.pdf ASHRAE LO-09-026-2009 Humidification of Large-Scale Cleanrooms by Adiabatic Humidification Method in Subtropical Areas An Industrial Case Study《通过绝热增湿法测定亚热带地区大尺度洁净室内的湿润性》.pdf
  • ASHRAE LO-09-027-2009 Required Duration For Borehole Test Validated by Field Data《通过现场数据对确定钻孔测试所需时间》.pdf ASHRAE LO-09-027-2009 Required Duration For Borehole Test Validated by Field Data《通过现场数据对确定钻孔测试所需时间》.pdf
  • ASHRAE LO-09-028-2009 Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems《传统置换通风房间和地下气体分.pdf ASHRAE LO-09-028-2009 Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems《传统置换通风房间和地下气体分.pdf
  • ASHRAE LO-09-029-2009 Air Distribution Effectiveness with Stratified Air Distribution Systems《分层气流组织系统中气流组织效能的研究》.pdf ASHRAE LO-09-029-2009 Air Distribution Effectiveness with Stratified Air Distribution Systems《分层气流组织系统中气流组织效能的研究》.pdf
  • ASHRAE LO-09-030-2009 In-Situ Performance of Stratified Air Distribution Systems in Two Canadian Buildings《两个加拿大建筑中分层空气分配系统的原地性能》.pdf ASHRAE LO-09-030-2009 In-Situ Performance of Stratified Air Distribution Systems in Two Canadian Buildings《两个加拿大建筑中分层空气分配系统的原地性能》.pdf
  • ASHRAE LO-09-031-2009 Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System《关于带有分层空调系统的大型建筑中气流分布的设计.pdf ASHRAE LO-09-031-2009 Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System《关于带有分层空调系统的大型建筑中气流分布的设计.pdf
  • ASHRAE LO-09-032-2009 Contaminant Transport and Filtration Issues with DOAS《用DOAS垃圾运输和过滤处理问题》.pdf ASHRAE LO-09-032-2009 Contaminant Transport and Filtration Issues with DOAS《用DOAS垃圾运输和过滤处理问题》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1