ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf

上传人:amazingpat195 文档编号:524951 上传时间:2018-12-04 格式:PDF 页数:7 大小:111.09KB
下载 相关 举报
ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf_第1页
第1页 / 共7页
ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf_第2页
第2页 / 共7页
ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf_第3页
第3页 / 共7页
ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf_第4页
第4页 / 共7页
ASTM D7251-2009 9375 Standard Specification for Color and Appearance Retention of Variegated Color Plastic Siding Products.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D7251 09An American National StandardStandard Specification forColor and Appearance Retention of Variegated Color PlasticSiding Products1This standard is issued under the fixed designation D7251; the number immediately following the designation indicates the year oforiginal adoption or,

2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification establishes requirements and testmethods for the color and a

3、ppearance retention of variegatedcolor plastic siding products.1.2 Color retention testing provides a method for estimatingthe acceptability of color change in a siding product over aperiod of years of service.1.3 Characterization of color and appearance for variegatedcolors is complicated by the pr

4、esence of multiple colors in arandom pattern. The procedure is based on using a template toreference 6 spots for color measurement.1.4 Methods of indicating compliance with this specifica-tion are provided.1.5 This standard does not purport to address all of thesafety concerns, if any, associated wi

5、th its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Termi

6、nology Relating to PlasticsD1435 Practice for Outdoor Weathering of PlasticsD1600 Terminology for Abbreviated Terms Relating toPlasticsD2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE805 Practice for Identification of Instrumental

7、 Methods ofColor or Color-Difference Measurement of MaterialsG147 Practice for Conditioning and Handling of Nonmetal-lic Materials for Natural and Artificial Weathering Tests3. Terminology3.1 DefinitionsDefinitions are in accordance with termi-nologies in Terminologies D883 and D1600 unless otherwis

8、enoted.3.2 Definitions of Terms Specific to This Standard:3.2.1 color regionparameters that define the color spacefor a siding sample. Color is measured with Hunter Units,sphere geometry (di:8), Illuminant C, 2 Observer, specularcomponent included.3.2.1.1 DiscussionThe color values used to classify

9、colorsby region were established by measuring the Hunter L, a, bcolor values from the sample population, calculating theaverage for Hunter L, a, b, and then choosing the integer fromthe corresponding L, a, b average values (that is, by truncatingany fractional result) to be used to classify colors b

10、y region.Thus, average values greater than zero are truncated down tothe next lowest integer, and average values less than zero aretruncated up to the next highest integer. All values greater than-1 and less than +1 truncate to 0.3.2.2 color retention standardspredictive color regionsdescribed by a

11、three dimensional model which constituteacceptable color retention levels resulting from weathering ofa specific product type and color.3.2.2.1 DiscussionColor retention standards are definedby equations that describe the three dimensional ellipsoidvalue.3.2.3 ellipsoid valuea mathematical calculati

12、on derivedby inserting the measured DL, Da, and Db values of aweathered specimen into an ellipsoid equation.3.2.4 temperate northern climatein weathering testing,aNorth American metropolitan area testing site located within73 to 100W longitude and 37 to 45N latitude.3.2.5 variegated plastic sidingsi

13、ding having discretemarkings of different colors.4. Classification4.1 DefinitionsDefinitions are in accordance with termi-nology in Terminologies D883 and D1600 unless otherwisenoted.1This specification is under the jurisdiction of ASTM Committee D20 onPlastics and is the direct responsibility of Su

14、bcommittee D20.24 on Plastic BuildingProducts.Current edition approved Nov. 1, 2009. Published December 2009. Originallyapproved in 2006. Last previous edition approved in 2006 as D7251 - 06. DOI:10.1520/D7251-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cu

15、stomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock

16、en, PA 19428-2959, United States.4.2 Color RegionsThe color region for a color is deter-mined by measuring the Hunter L, a, b color values at sixlocations on each specimen in a sample population andcalculating the average Hunter L, a, b color value. Use theinteger value (by truncating any fractional

17、 result) of theaverage to determine the color region for the color using thefollowing region boundaries.4.2.1 Region 1BrownL = 20 to 49 L = 25 to 49a=1to5 a=8to5b=2to11 b=12to254.2.2 Region 2Medium BlueL = 45 to 64a = 26 to 1b = 25 to 24.2.3 Region 3Light BlueL = 65 to 93a = 12 to 1b = 25 to 24.2.4

18、Region 4GreenL = 50 to 84 L = 50 to 64 L = 50 to 64a = 12 to 1 a = 25 to 3 a = 25 to 13b=1to10 b=11to30 b=1to10L = 65 to 93 L = 85 to 93a = 25 to 13 a = 12 to 3b=25to30 b=1to34.2.5 Region 5Medium BeigeL = 50 to 74 L = 50 to 64 L = 65 to 74a=0to1 a=2to1 a=12to1b=4to12 b=11to15 b=11to124.2.6 Region 6L

19、ight BeigeL = 75 to 84 L = 85 to 93 L = 75 to 84a=0to1 a=12to1 a=12to1b=4to12 b=4to12 b=11to124.2.7 Region 7GoldL = 65 to 93a=0to4b=13to304.2.8 Region 8YellowL = 65 to 93a = 12 to 1b=13to304.2.9 Region 9WhiteL = 85 to 100 All L = 94 to 100a=2to1b=1to34.2.10 Region 10Light GrayL = 65 to 84a=0to1b=1to

20、34.2.11 Region 11MauveL = 65 to 93 L = 65 to 93 L = 50 to 64 L = 50 to 64a=2to25 a=5to25 a=2to25 a=2to1b=2to12 b=13to15 b=2to30 b=16to304.2.12 Region 12Medium GrayL = 50 to 64a=0to1b=1to34.2.13 Region 13Dark GrayL = 25 to 49a=1to5b=1to14.2.14 Region 14Dark BlueL = 25 to 44a = 25 to 3b = 25 to 24.2.1

21、5 Region 15Dark GreenL = 25 to 49a = 20 to 2b=1to114.2.16 Region 16Dark RedL = 25 to 49a=6to30b=1to254.2.17 Region 17PurpleL = 25 to 44 L = 45 to 49 L = 50 to 93a=4to30 a=2to30 a=2to25b = 25 to 2 b = 25 to 2 b = 25 to 14.3 Ellipsoid Value EquationsUse the following equationsto determine the ellipsoi

22、d value representing the change incolor due to weathering. Use the equation that corresponds tothe color region determined for the specimens initial color(prior to weathering) in 4.2.4.3.1 Region 1BrownDL 1.6!25.2!21Da 1 1.0!23.0!21Db 0.5!22.5!25 Ellipsoid Value4.3.2 Region 2Medium BlueDL 1 1.0!26.0

23、21Da 1 0.6!22.9!21Db 0.8!25.4!25 Ellipsoid Value4.3.3 Region 3Light BlueDL 1 0.3!26.4!21Da 1 0.1!22.7!21Db 0.8!24.3!25 Ellipsoid Value4.3.4 Region 4GreenDL 0.2!25.9!21Da 0.8!24.8!21Db 0.2!25.6!25 Ellipsoid Value4.3.5 Region 5Medium BeigeDL 1 0.1!26.1!21Da 0.0!22.8!21Db 0.4!23.9!25 Ellipsoid Value4.

24、3.6 Region 6Light BeigeDL 0.0!25.0!21Da 0.2!22.6!21Db 0.3!25.4!25 Ellipsoid Value4.3.7 Region 7GoldDL 1 0.6!26.6!21Da 1 0.3!23.4!21Db 1 0.4!24.7!25 Ellipsoid Value4.3.8 Region 8YellowDL 1 0.3!25.5!21Da 1.0!23.3!21Db 1 0.1!25.5!25 Ellipsoid ValueD7251 0924.3.9 Region 9WhiteDL 0.6!28.2!21Da 1 0.0!23.3

25、21Db 1.9!25.3!25 Ellipsoid Value4.3.10 Region 10Light GrayDL 1 1.8!27.0!21Da 0.2!22.1!21Db 1.3!24.0!25 Ellipsoid Value4.3.11 Region 11MauveDL 0.4!26.5!21Da 0.8!24.0!21Db 1.1!24.5!25 Ellipsoid Value4.3.12 Region 12Medium GrayDL 1 1.0!26.6!21Da 1 0.3!22.5!21Db 1.2!23.7!25 Ellipsoid Value4.3.13 Region

26、 13Dark GrayDL 0.1!25.1!21Da 1 0.8!23.4!21Db 1 0.1!23.0!25 Ellipsoid Value4.3.14 Region 14Dark BlueDL 0.3!25.2!21Da 1.0!23.6!21Db 1 1.3!24.5!25 Ellipsoid Value4.3.15 Region 15Dark GreenDL 0.0!25.0!21Da 1 0.4!23.0!21Db 1 0.2!23.8!25 Ellipsoid Value4.3.16 Region 16Dark RedDL 0.4!25.4!21Da 0.8!24.0!21D

27、b 0.2!23.0!25 Ellipsoid Value4.3.17 Region 16PurpleDL 0.0!26.0!21Da 0.0!25.0!21Db 0.0!25.2!25 Ellipsoid Value5. Procedure for Measuring Color Retention5.1 Test Site Setup and Exposure Duration Test Times:5.1.1 Samples shall be exposed at three test sites: TemperateNorthern represented by a site loca

28、ted in Louisville, KY orCleveland, OH; hot, humid represented by a site located inMiami, FL, and hot, dry represented by a site located inPhoenix, Arizona. Additional test sites are permitted as agreedupon by the buyer and the seller.5.1.2 All exposures shall be conducted at an angle of 45facing Sou

29、th and backed using unpainted plywood in accor-dance with Practices D1435 and G147.5.1.3 Remove test specimens for color measurement at24-month exposure. In some cases, 24 months are not sufficientto distinguish material durability differences and longer expo-sure periods are necessary. Additional e

30、xposure times arepermitted as agreed upon by the buyer and the seller.5.2 Sampling and Specimen Preparation:5.2.1 Samples shall be representative of the product to beevaluated.NOTE 2Samples prepared in the laboratory in the same manner ascommercial samples are an acceptable alternate to a commercial

31、 part. Ifthe commercial product is extruded, the laboratory specimen must beextruded; if the commercial product is injection molded, the laboratoryspecimen must be injection molded, and so forth.5.2.2 Select a minimum of four specimens per sample pertest site to allow for three test specimens and on

32、e file specimenfor each sample evaluated.5.2.3 The file specimen will be used for a visual assessmentof variegation/contrast change. The test specimens will bemeasured for color and weathered.5.2.4 Specimens shall be a flat section and a minimum of 3by 10 in. (76 by 254 mm). The variegated pattern s

33、hall beparallel to the long edge of the specimen.5.2.5 Use the Variegated Color Measurement Template toidentify the 6 spots on each test specimen for color retentiontesting. The center points of these 6 spots are specified in Fig.1. The diameter of the six spots is specified as 0.50 in. (12.2mm) min

34、imum. Those shown in the diagram are for illustrationonly.5.2.6 The exact locations of these test spots must bedetermined and recorded for each test specimen to allowmeasurement of color change following exposure testing.5.2.7 The locations and spot sizes identified in 5.2.5 for eachtest specimen sh

35、all not change once the exposure test is started.5.2.8 Mark each specimen permanently to ensure retentionof identity during and after exposure testing.NOTE 3Use of a vibratool leaves a permanent mark that satisfies thiscriteria.5.3 Data Record:5.3.1 Measured specimen color values shall be reported t

36、oone decimal place.5.3.2 Calculation of color units shall be reported to onedecimal place.5.4 Practice:5.4.1 Obtain test and file specimens in accordance with 5.2.5.4.2 Measure the original tristimulus X, Y, and Z values forthe 6 spots identified in 5.2.5 for each test specimen. Color ismeasured usi

37、ng sphere geometry (di:8), illuminant C, 2observer, specular component included in accordance withPractice E805. The minimum aperture size for color measure-ment 0.50 in. (12.2 mm).5.4.3 Calculate the Hunter L, a, and b units in accordancewith the equations in the section on “Hunter L, a, and b Colo

38、rSpace and Color-Difference Equation” in Test Method D2244using the average of the six measurements and record in apermanent record.5.4.4 The measured average color of each test specimen isthe specimens initial color and is used to determine colorchange after specified periods of exposure testing.5.

39、4.5 Repeat steps 5.4.2 through 5.4.4 for each test speci-men.5.4.6 Calculate the average color in Hunter L, a, b for thethree test specimens to determine their color region as definedin 4.2.5.4.6.1 Calculate the overall average color of the 3 testspecimens for each test site from step 5.4.5.5.4.6.2

40、A single color region must be determined and usedat all test sites. If the color regions determined for each test siteare not the same, re-measure the test specimens for thenon-conforming test site. If the three test sites still do not agree,D7251 093calculate the overall average color for test spec

41、imens from allsites to determine the samples color region.5.4.7 Expose the test specimens at the test sites in accor-dance with 5.1.1 and 5.1.2. Record in a permanent record thetest start date.5.4.8 Remove the test specimens at the exposure interval(s)in accordance with 5.1.3. Record in a permanent

42、record thedate the specimens are removed from the exposure test rack forcolor measurement.5.4.9 The exposed test specimens shall be measured forcolor and evaluated for appearance. It is recommended thatcolor measurement and appearance evaluation be conducted atthe test site. Color measurement shall

43、take place within sevendays of specimen removal from the exposure test rack. It isrecommended that color measurement take place within 48 h ofthe specimens removal from the exposure test rack.NOTE 4Additional color development is known to occur for PVCproducts after removal from exposure to ultravio

44、let (UV) light. Thisartificial color change is referred to as Dark Time Yellowing. Colormeasurement within 48 h of removal is strongly recommended for PVCproducts.5.4.10 Wash the exposed test specimens in accordance withthe procedure in Annex A1.5.4.11 Inspect each exposed test specimen for appearan

45、ceand surface condition. Record observations and inspection datein a permanent record.5.4.12 Referencing the file specimen, evaluate each testspecimen for loss of variegation in accordance with 6.3.5.4.13 Measure and record the color of each test specimenin accordance with 5.4.2 through 5.4.3 for ea

46、ch exposure time.Record in a permanent record the date the color of thespecimen(s) is measured.FIG. 1 Variegated Color Measurement TemplateD7251 0945.4.14 Referencing each test specimens initial color deter-mined in 5.4.5, calculate and record the color change in HunterL, a, and b units for each tes

47、t specimen.5.4.15 In cases where specimens are evaluated at exposuretimes other than 24 months, the specimens shall be returned tothe exposure test rack within 7 days for continuation of the test;it is recommended the samples be returned to the test rackswithin 48 h. Record in a permanent record the

48、 date thespecimens are returned to the exposure test rack.NOTE 5In case of dispute, the referee procedure shall be the use ofseparate specimens for each exposure time that can then be disposed aftercolor measurements are made.6. Performance Requirements6.1 Using the ellipsoid value equations in 4.3,

49、 calculate theellipsoid value for each test specimen using the measured colorchange determined in 5.4.14 and the appropriate color regiondetermined in 5.4.6.6.2 Acceptable color retention is determined by the averageellipsoid value of the three test specimens at each test locationbeing less than or equal to 1.0. T