ASTM D7541-2011(2015) 1655 Standard Practice for Estimating Critical Surface Tensions《估算临界表面张力的标准实施规程》.pdf

上传人:syndromehi216 文档编号:525755 上传时间:2018-12-04 格式:PDF 页数:3 大小:69.67KB
下载 相关 举报
ASTM D7541-2011(2015) 1655 Standard Practice for Estimating Critical Surface Tensions《估算临界表面张力的标准实施规程》.pdf_第1页
第1页 / 共3页
ASTM D7541-2011(2015) 1655 Standard Practice for Estimating Critical Surface Tensions《估算临界表面张力的标准实施规程》.pdf_第2页
第2页 / 共3页
ASTM D7541-2011(2015) 1655 Standard Practice for Estimating Critical Surface Tensions《估算临界表面张力的标准实施规程》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D7541 11 (Reapproved 2015)Standard Practice forEstimating Critical Surface Tensions1This standard is issued under the fixed designation D7541; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.

2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for estimating values ofthe critical surface tension of surfaces by observing the wettingand dewettin

3、g of a series of liquids (usually organic solvents)applied to the surface in question.1.2 Another technique, measurement of the contact angles, of a series of test liquids and plotting cos versus surfacetension (Zisman plots), provides data that allow the determi-nation of more exact values for crit

4、ical surface tension.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stand

5、ard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2578 Test Method for Wetting Tension of Polyethylene andPolypropylene Films2.2 Nordtest Standards:3NT poly 176 Spreading Surfa

6、ce Tension by the AppliedDroplet Method.3. Terminology3.1 Definitions:3.1.1 critical surface tension, nthe surface tension of ahypothetical liquid that would just spontaneously spread ifapplied as a drop to the surface in question; any liquid with asurface tension lower than the critical surface ten

7、sion willspread spontaneously.4. Summary of Practice4.1 In this practice, a series of liquids of gradually increas-ing surface tension are applied to a surface in the form ofdrops, narrow strips, or spots. Drops may be applied using adropper, syringe or other device capable of producing indi-vidual

8、drops. Liquid strips or spots are applied to the surface byswabbing with saturated cotton swabs or by another type ofapplicator, such as one that is similar to a marker pen. In thecase of the drop, the observer determines whether the dropstays in place or spreads. In the case of the liquid strip or

9、spot,the question is whether the liquid stays in place or dewets andcrawls. In each case, the break point between wetting anddewetting provides the critical surface tension.5. Significance and Use5.1 Knowledge of the critical surface tension of substrates,primers and other coatings is useful for exp

10、laining or predict-ing wettability by paints and other coatings applied to thosesurrfaces. Surfaces with low critical surface tensions usuallyare prone to suffer defects such as crawling, picture framing,cratering and loss of adhesion when painted. Low or irregularvalues, or both, often are indicati

11、ve of contamination that couldreduce adhesion. Surfaces with high critical surface tensionsare easy to wet and usually provide an excellent platform forpainting.5.2 The swab, marking pen and draw-down tests all simu-late the application of a film5.3 The swab and marking pen techniques are simple and

12、rapid and are particularly useful for testing in the field or oncurved, irregular or porous surfaces where contact anglescannot be measured. The drop test does not work well on suchsurfaces and the draw-down method requires a flat specimenthat is relatively large.5.4 The estimation of critical surfa

13、ce tension has beenuseful in characterizing surfaces before and after cleaningprocesses such as power washes and solvent wipes in order toevaluate the efficiency of the cleaning.5.5 One or more of these techniques could be the basis of ago/no-go quality control test where if a certain liquid wets, t

14、he1This practice is under the jurisdiction of ASTM Committee D01 on Paint andRelated Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.23 on Physical Properties of Applied Paint Films.Current edition approved June 1, 2015. Published June 2015. Originallyapprov

15、ed in 2009. Last previous edition approved in 2011 as D7541 11. DOI:10.1520/D7541-11R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summa

16、ry page onthe ASTM website.3For Nordtest standards, see or contactNordtest, Tekniikantie 12, FIN-02150 Espoo, Finland.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1surface is acceptable for painting, but if that liquid retracts and

17、crawls, the surface is not acceptable.5.6 Another go/no go test is possible where the test liquid isa paint and the surface is a substrate, primer or basecoat. Aform of this test has been used for coatings for plastics.6. Interferences6.1 The specimen must be clean in order for results to bemeaningf

18、ul. The surface must not be touched or rubbed.6.2 The surface tensions of test liquids, especially those thatare mixtures, are subject to change with time. Test liquidsurface tensions should be confirmed before they are first used,measured periodically after that and whenever change issuspected.6.3

19、Test liquids may become contaminated, in which caseresults with them will be meaningless. Test liquid surfacetensions should be confirmed before they are first used,measured periodically after that and whenever contamination issuspected.6.4 High ambient temperature may cause rapid evaporationof test

20、 liquids and make it difficult to determine whetherretraction has occurred or shrinkage is due to evaporation.7. Apparatus7.1 Several of one of the following types of applicators:7.1.1 Cotton swab (small ball of cotton at the end of a stick).7.1.2 Marker pen type applicator.7.1.3 Dropper or syringe.

21、7.1.4 Other device with the ability to apply a drop, strip, orspot.7.2 Drawdown Baronly for draw-down test.7.3 Instrument or devices for measuring temperature andhumidity.8. Materials8.1 Swab, drop and draw-down tests.8.1.1 Test liquids.8.1.1.1 The original publication on the swab test4specifiedthe

22、liquids in Table 1 (listed along with their surface tensions).This set of liquids has a large surface tension gap between 24and 35 dynes/cm.8.1.1.2 Test Method D2578 specifies mixtures of formamideand ethylene glycol monomethyl ether (both reagent grade).Mixtures can be designed so as to produce any

23、 combination ofsurface tension values.8.1.1.3 The drop test publications5,6specify mixtures ofethanol and water, but do not give details of the proportions.8.1.1.4 Nordtest Method NT poly 1763includes a table ofsurface tensions for ethanol/water mixtures at 23C, whichgives values ranging from 22 to

24、72 mN/m in 2 mN/m intervals.8.1.1.5 Other liquids covering a range of surface tensionscould be used. If possible, highly volatile solvents should beavoided as it is difficult to tell whether they are dewetting orjust evaporating.9. Preparation of Specimens9.1 The areas tested shall not contain visib

25、le blemishes ordefects and shall not be touched with the fingers or be allowedto be contaminated in any way.9.2 Specimens may be cleaned, bearing in mind that thesurface of the specimen may be affected by the cleaningprocess. Any cleaning method should be chosen only afterconsidering how the process

26、 may alter the surface. Cleaningmust be clearly indicated in the report.10. ProcedureCotton Swab10.1 Beginning with the lowest surface tension liquid in thetest series, saturate the cotton ball at the end of the stick andapply three uniform strips 0.5 to 1 cm wide and 2 to 5 cm longto the test speci

27、men.10.2 Observe whether the liquid remains as an intact film,retracts (crawls) or completely beads up. Allow 3 seconds forretraction or beading to occur. Longer times may be used, butevaporation of the liquid may cause retraction that appears tobe dewetting, but is not.10.3 If the liquid strip does

28、 not retract or bead up within 3seconds, repeat the procedure on an untested section of thespecimen with a clean cotton swab and the next higher surfacetension liquid. If the strip does retract or bead in the initial test,a lower surface tension test liquid must be found and used.10.4 Each of the li

29、quids in the series is used to test thespecimen until one of them clearly retracts. There are twodifferent conventions for determining the end point and esti-mating the critical surface tension:10.4.1 The critical surface tension of dewetting is taken asbeing intermediate between the surface tension

30、 value of the lastliquid that wet the surface and the first one that did not. Forexample, if a 34 mN/m liquid wets the specimen and a 36mN/m liquid does not, the critical surface tension will beconsidered to be approximately 35 mN/m.10.4.2 The critical surface tension is taken as the highestsurface

31、tension liquid that just wets the surface. Using thiscriterion, the critical surface tension in the example in 10.4.1would be considered to be approximately 34 mN/m.4Hansen, C. M., J. Coat. Technol., 44 (570), 57 (1972).5Hansen, C. M., European Coatings J., 94, 838 (1994).6Hansen, C. M., Pigment and

32、 Resin Technol., 27, 374 (1998).TABLE 1 Test Liquids and Their Surface TensionsLiquidSurfact TensionmN/m (= dynes/cm)Acetone 23.7Dimethyl formamide 35.22-pyrollidone 37.6N-methyl-2-pyrollidone 39.0Dimethyl sulfoxide 43.0Ethylene cyanohydrin 44.4Formamide 56.0Water 72.8D7541 11 (2015)211. ProcedureMa

33、rker Pen Applicator11.1 Begin with the marker pen with the lowest surfacetension.11.2 Press the applicator tip firmly on the corner of thespecimen until the tip is fully saturated with the ink.11.3 Lightly draw the pen across the specimen in threeparallel passes. One of the pen manufacturers specifi

34、es onlyevaluating the last pass.11.4 If the last ink strip remains wetted for 3 seconds ormore, repeat steps 11.2 and 11.3 on an untested portion of thespecimen with the next higher surface tension marker pen.11.5 Continue testing until the paint strip clearly retracts.Aswith the cotton swab test, t

35、here are two conventions fordetermining the end point and estimating the critical surfacetension. See 10.4.1 and 10.4.2 for details.12. ProcedureDrop Test12.1 Beginning with the lowest surface tension test liquid,place a small drop of the test liquid on the test specimen.12.2 Observe whether the liq

36、uid spreads. If it does, apply adrop of the next higher surface tension liquid.12.3 Continue with higher and higher surface tension liq-uids until a drop does not spread.12.4 See 10.4.1 and 10.4.2 for the two conventions used inestimating the critical surface tension from the observations.12.5 An ex

37、ample is shown in Fig. 1. The surface has acritical surface tension between 22 and 26 dynes/cm. Liquidswith surface tensions equal to or higher than 26 dynes/cm donot wet the surface and, therefore, retain their droplet form.13. ProcedureDraw-Down Test13.1 Aflat specimen, preferably on the order of

38、20 by 25 cmis placed on and clamped to a work bench or table.13.2 Several test liquid drops are placed across the top ofthe specimen with space between them. The liquids shouldrange from low to high surface tension, increasing from left toright. A draw-down bar is placed above the drops and pulleddo

39、wn. The resultant draw-downs are quickly examined forwetting and dewetting behavior.13.3 As with the other methods, there should be a breakpoint between the draw-down strips that wet and those thatdewet and retract.14. Report14.1 The report shall contain the following informationwhen applicable and

40、available.14.1.1 Date, time, and place of the measurement.14.1.2 Description of the test specimen.14.1.3 Whether specimen is as-received or whether cleaninghas been done. If the latter, then describe the cleaning process.14.1.4 Temperature and humidity in the area of the test.14.1.5 Identification o

41、f the test and applicator that wereused.14.1.6 If the drop test is used, indicate the drop size.14.1.7 Any deviations from the method.14.1.8 Identification of which convention was used to esti-mate the critical surface tension.14.1.9 The estimated value for the critical surface tension inmN/m.15. Ke

42、ywords15.1 critical surface tension; dewetting; surface contamina-tion; wettability; wettingASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determinatio

43、n of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdra

44、wn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your c

45、omments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single

46、or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 1 Drops of Different Surface Tension Liquids on a Low Surface Tension Surface. Left to Right: Low to High Surface Tension Liq-uids; Spreading to BeadingD7541 11 (2015)3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1