ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf

上传人:livefirmly316 文档编号:528032 上传时间:2018-12-05 格式:PDF 页数:8 大小:120.30KB
下载 相关 举报
ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf_第1页
第1页 / 共8页
ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf_第2页
第2页 / 共8页
ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf_第3页
第3页 / 共8页
ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf_第4页
第4页 / 共8页
ASTM E1155M-1996(2001) Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers [Metric]《使用F-数字制测定楼板平正度和水平度的试验方法(米制)》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E 1155M 96 (Reapproved 2001)METRICStandard Test Method forDetermining FFFloor Flatness and FLFloor Levelness NumbersMetric1This standard is issued under the fixed designation E 1155M; the number immediately following the designation indicates the year oforiginal adoption or, in the case

2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a quantitative method of mea-suring floor surface profiles to obtai

3、n estimates of the floorscharacteristic FFFlatness and FLLevelness Face Floor ProfileNumbers (F-Numbers) using the metric (SI) system of units.NOTE 1This is the metric companion to Test Method E 1155.1.2 The text of this test method references notes andfootnotes that provide explanatory material. Th

4、ese notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of this test method.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-

5、priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 1155 Test Method for Determining FFFloor Flatness andFLFloor Levelness Numbers22.2 ACI Standard:ACI 117-90 Standard Specifications for Tolerances for

6、 Con-crete Construction and Materials33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 elevationheight, altitude, vertical location in space.Elevation measurements are always made parallel to thedirection of gravity.3.1.2 flateven, plane, homoloidal, free of undulation.3.1.2.1

7、DiscussionFor the purposes of this test method,flatness will be measured by calculating curvature value, q,between all 12-in. reading points separated by 24 in. Thecurvature value is the difference between successive elevationdifferences. The mean and standard deviation of all thecurvature values fo

8、r a given test section are then convertedaccording to the equations in this test method to get thedimensionless FFFlatness Number.3.1.3 floor profilometera Type I device (see 6.1.1) thatproduces a continuous record of the elevation of a single pointmoving along a line on the floors surface.3.1.4 hor

9、izontallevel, normal to the direction of gravity.3.1.5 inclinometera Type II device (see 6.1.2) that mea-sures the angle between horizontal and the line joining the twopoints of contact with the floors surface.3.1.6 levelhorizontal, normal to the direction of gravity.3.1.6.1 DiscussionFor the purpos

10、es of this test method,levelness will be measured by collecting elevation differencesat points spaced 10 ft apart and that will be described by the FLLevelness number (dimensionless).3.1.7 longitudinal differential floor profilometer, na TypeII device (see 6.1.2) that produces a continuous record of

11、 theelevation difference between two points moving along a line onthe floors surface, which two points remain separated by afixed distance.3.1.8 sample measurement linea sample measurementline shall consist of any straight line on the test surface alongwhich measurements are taken, with the limitati

12、ons listed in7.3.3.1.9 sign conventionwhere up is the positive direction;down is the negative direction. Consequently, the higher thereading point, the more positive its hivalue, and the lower thereading point, the more negative its hivalue. Similarly, theelevation difference from a low point to a h

13、igh point (that is, anuphill difference) is positive, while the elevation differencefrom a high point to a low point (that is, a downhill difference)is negative.3.1.10 test sectiona test section consists of any subdivi-sion of the test surface with the limitations listed in 7.2.3.1.11 test surfaceon

14、 any one building level, the entirefloor area of interest constitutes the test surface, with thelimitations listed in 7.1.3.1.12 verticalparallel to the direction of gravity.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility

15、of Subcommittee E06.21on Serviceability.Current edition approved April 10, 2001. Published May 1996. Originallypublished as E 1155M 87. Last previous edition E 1155M 87e1.2Annual Book of ASTM Standards, Vol 04.11.3Available from American Concrete Institute, P.O. Box 19150, Detroit, MI48219-0150.1Cop

16、yright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2 Symbols:3.2.1 Aiarea of Test Section i.3.2.2 didifference in elevation (in millimetres) betweenreading points Piand Pi1(i $ 1).3.2.3 FfFace FFFlatness Number (dimensionless).3.2.4 Ffico

17、mposite FFFlatness Number for Test Section i.3.2.5 FlFace FLLevelness Number (dimensionless).3.2.6 Flicomposite FLLevelness Number for Test Sectioni.3.2.7 hielevation (in millimetres) of Reading Point Pi(i$0).3.2.8 njnumber of reading points in Test Sample j (nj$12).3.2.9 Nminminimum number of 3-m e

18、levation differencereadings required per the test section.3.2.10 qiarithmetic difference (in millimetres) betweenelevation differences diand di1(i $ 2).3.2.11 rxjnumber of readings of Variable x obtained fromSample j.3.2.12 sxjstandard deviation of Variable x in Sample j.3.2.13 Vxjvariance of Variab

19、le x in Sample j.3.2.14 zidifference in elevation (in millimetres) betweenReading Points Piand Pi10(i $ 10).4. Summary of Test Method4.1 Straight lines are marked at various locations on thefloor surface. Point elevations are then measured at regular300-mm intervals along each line. The elevation di

20、fferencesbetween all adjacent reading points are calculated, and astraight line approximation to the surface profile along eachmeasurement line is produced and evaluated for consistencywith visual observation of the floor surface.4.2 The arithmetic differences between all adjacent 300-mmelevation di

21、fferences and the elevation differences between allpoints separated 3 m are then calculated. Estimates of each testsections floors FFFlatness and FLLevelness F-Numbers areobtained through statistical analyses of these calculated profilevalues. Finally, the F-Numbers for each test section arecombined

22、 to arrive at a composite set of F-Numbers for eachtest surface.5. Significance and Use5.1 This test method provides statistical (and graphical)information concerning floor surface profiles.5.2 Results of this test method are used primarily to:5.2.1 Establish compliance of randomly trafficked floors

23、urfaces with specified FFFlatness and FLLevelness toler-ances,5.2.2 Evaluate the effect of different construction methodson resulting floor surface flatness and levelness, and5.2.3 Investigate the curling and deflection of floor surfaces.5.3 Results of this test method shall not be used to enforceco

24、ntract flatness and levelness tolerances on those floor instal-lations primarily intended to support the operation of fixed-path vehicle systems (for example, narrow aisle warehousefloors).NOTE 2When the traffic patterns across a floor are random, (as isgenerally the case) evaluation of the floors F

25、FFlatness and FLLevelnesswill necessarily involve a random sampling of the surface, since all of theinfinite potential profiles to be seen by the traffic can not possibly bemeasured. In those instances when the traffic across a floor will beconfined to specific paths, however, the requirement for ra

26、ndom samplingis eliminated, since the floor can indeed be inspected exactly as it will beseen by all of the traffic. In these special cases, rather than inferring thecondition of the traffic paths from a random sample, it is far more usefulto measure each of the traffic paths directly using continuo

27、us recordingfloor profilometer configured to run exactly in the traffic wheel paths. Suchdirect simulation measurements eliminate the inherent uncertainties ofstatistical sampling and provide profile information immediately appli-cable to the correction of the surface in way of the future traffic.6.

28、 Apparatus6.1 Point Elevation Measurement Device:6.1.1 Type I ApparatusIf a Type II apparatus (see 6.1.2)isnot used for this test, then an apparatus capable of measuringthe elevations of a series of points spaced at regular 300-mmintervals along a straight line on the floor surface shall be used.Exa

29、mples of satisfactory Type I point elevation measurementdevices include, but are not limited to the following:6.1.1.1 Leveled Straightedge, with gage (for example, tri-square, dial indicator, etc.) to measure vertical distance fromthe upper straightedge surface to floor.6.1.1.2 Leveled Straightedge,

30、 with graduated wedges orshims to measure vertical distance from lower straightedgesurface to floor.6.1.1.3 Optical Level, with vernier or scaled target.6.1.1.4 Laser Level, with vernier or scaled target.6.1.1.5 Taut Level Wire, with gage to measure verticaldistance from wire to floor.6.1.1.6 Floor

31、Profilometer.6.1.2 Type II ApparatusIf a Type I apparatus (see 6.1.1)isnot used for this test, then an apparatus capable of measuringthe elevations of a series of points spaced at regular 300-mmintervals along a straight line on the floor surface shall be used.Examples of satisfactory Type II point

32、elevation measurementdevices include, but are not limited to the following:6.1.2.1 Inclinometer, having 300-mm contact point spacing.6.1.2.2 Longitudinal Differential Floor Profilometer, having300-mm sensor wheel spacing.6.2 Ancillary Equipment:6.2.1 Measurement Tape, graduated in millimetres.6.2.2

33、Chalk Line (or other means for marking straight lineson the test surface).6.2.3 Data Recording MeansThis procedure requires therecording of both verbal and numeric information. Examples ofsatisfactory data recording means include, but are not limitedto the following:6.2.3.1 Manual Data Sheet.6.2.3.2

34、 Magnetic Tape Recorder (voice or direct input).6.2.3.3 Paper Chart Recorder.6.2.3.4 Direct Computer Input.NOTE 3Since the bias of the results obtained with this test methodwill vary directly with the accuracy of the particular measurement deviceemployed, all project participants should agree on the

35、 exact test apparatusto be used prior to the application of this test method for contractspecification enforcement.E 1155M 96 (2001)27. Organization of Test Area7.1 Test SurfaceOn any one building level, the entire floorarea of interest shall constitute the test surface.7.1.1 When this test method i

36、s used to establish complianceof randomly trafficked floor surfaces with specified FFFlatnessand FLLevelness tolerances, each portion of the surface whichhas a unique specified set of tolerances must be treated as aseparate surface.7.2 Test SectionA test section shall consist of any subdi-vision of

37、a test surface satisfying the following criteria:7.2.1 No test section shall measure less than 2.4 m on a side,nor comprise an area less than 12 m2.7.2.2 No portion of the test surface shall be associated withmore than one test section.7.2.3 When testing a concrete floor, no test section boundarysha

38、ll cross any construction joint.7.3 Sample Measurement LineA sample measurementline shall consist of any straight line on the test surfacesatisfying the following criteria:7.3.1 No sample measurement line shall measure less than3.3 m in length.7.3.2 When testing a concrete floor, no portion of anysa

39、mple measurement line shall fall within 600 mm of any slabboundary, construction joint, isolation joint, block-out, penetra-tion, or other similar discontinuity.7.3.2.1 ExceptionShrinkage crack control joints formedeither by partial depth sawcuts or by partial depth inserts shallbe ignored.7.3.2.2 E

40、xceptionIf the area to be excluded from mea-surement exceeds 25 % of the test section area, then the600-mm boundary exclusion shall not apply.7.3.3 Measurement lines may not be placed parallel to eachother closer than 1.2 m.7.4 Type I Test Sample (Measured With Type IApparatus)AType I test sample sh

41、all consist of not less thantwelve sequential point elevation measurements made at regu-lar 300-mm intervals along a single sample measurement line.7.5 Type II Test Sample (Measured With Type IIApparatus)A Type II test sample shall consist of not lessthan eleven sequential measurements of the elevat

42、ion differ-ences between adjacent reading points spaced at regular300-mm intervals along a single sample measurement line.7.6 Minimum Number of ziReadings Per Test SectionThenumber (or length) of Type I or Type II test samples to becollected within each test section shall be sufficient to yield (ina

43、ggregate) not less than Nminindividual measurements of zi,where Nminis calculated as follows:Nmin5 2=A 12#A#150! (1)5 A/3 A . 150!where:A = test section area, m2.7.7 Construction JointsWhere construction joints are re-quired to be measured, periodic measurements of the 600-mmcurvature qishall be tak

44、en, transverse to and centered on theconstruction joint. At least one qimeasurement shall be takenon each straight section of joint, with a maximum intervalbetween measurement locations not to exceed 3 m. Thesemeasurement locations shall be recorded.NOTE 4Since construction joints are a discontinuit

45、y in the floorsurface, measuring across them would introduce statistical anomalies intothis test method. Construction joints are therefore excluded from thegeneration of F-Number statistics. However, since traffic will neverthelesspass across many of the construction joints, a separate measurement a

46、ndanalysis of the joints may be required in order to provide a quantitativemeasure of the roughness of the joints themselves. Some joints may neversee traffic, for example, those along a wall. The particular joints requiredto be analyzed may be specified in contract specifications, along with amaxim

47、um allowable value for qi.8. Procedure8.1 Record the name and location of the subject building;the installation date of the subject floor, if known; the subjectfloors specified Ffand Flvalues; the make, model, and serialnumber of the test apparatus to be used; the date of the test; andthe name of th

48、e individual making the test.NOTE 5When this test is used to evaluate the compliance of a newconcrete floor with contract flatness and levelness specifications, thetimeliness of the test vis-a-vis the date of the floors installation is ofcritical importance. Since most concrete floors will change sh

49、ape signifi-cantly within a few days after installation, owing to inevitable shrinkageand deflection, the American Concrete Institute (see ACI 117-90) nowrequires that specified concrete floor tolerances be checked within 72 hafter floor installation in order to ensure that an accurate gage of thesurfaces “as-built” shape is assessed.8.2 Lay out the test surface.8.2.1 Divide the entire test surface into test sections. Assigna different identification number to each test section, andrecord the locations of all test section b