ASTM E1521-2001(2006) Standard Test Method for Liquid Holding Capacity of Granular Carriers《颗粒载波的液体储存容量标准试验方法》.pdf

上传人:王申宇 文档编号:528864 上传时间:2018-12-05 格式:PDF 页数:2 大小:50.80KB
下载 相关 举报
ASTM E1521-2001(2006) Standard Test Method for Liquid Holding Capacity of Granular Carriers《颗粒载波的液体储存容量标准试验方法》.pdf_第1页
第1页 / 共2页
ASTM E1521-2001(2006) Standard Test Method for Liquid Holding Capacity of Granular Carriers《颗粒载波的液体储存容量标准试验方法》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: E 1521 01 (Reapproved 2006)Standard Test Method forLiquid Holding Capacity of Granular Carriers1This standard is issued under the fixed designation E 1521; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la

2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the liquid holdingcapacity (LHC) of granular carriers.1.2 The values stated in ei

3、ther SI or inch-pound units are tobe regarded as standard. The values given in parentheses arefor information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate

4、safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 5.2. Summary of Test Method2.1 Incremental amounts of suitable fluids are added to aknown weight of granular carrier. The point at which thegranules

5、stick to the sides of the container allows calculation ofthe LHC.3. Significance and Use3.1 This test method has been designed principally forgranular carriers with LHC greater than 5.0 %. The incremen-tal amount of suitable fluid added can be adjusted down asneeded for carriers with LHC less than 5

6、.0 %.3.2 This test method is applicable to granules in the rangefrom 4 to 100 mesh (4.75 to 0.150 mm).4. Apparatus and Reagents4.1 Buret Stand.4.2 Buret, 10 to 25 mL, accurate to 0.2 mL.4.3 Glass Bottle, 1 oz (29.6 mL), with poly seal cap (7 by3.5-cm outside diameter).4.4 Glass Bottle, 8 oz (236.8 m

7、L), wide mouth with polyseal cap.4.5 Suitable Fluids, dearomatized mixed aliphatic solventslike Exxsol(R) D110 from Exxon Mobile Chemical Company,that boil in the range of 250275C and have a specific gravityof 0.800.82.4.6 Balance, accurate to 60.1 g.5. Safety Precautions5.1 Before testing, read the

8、 precautionary statements on theproduct label and material safety data sheet. Take properprecautions to prevent skin contact and inhalation of the finesand vapors. Take care to prevent contamination of the sur-rounding area. Always wear the appropriate safety equipmentand, where indicated, wear resp

9、iratory devices approved byNIOSH for the product being tested.6. Procedure6.1 Weigh 7.0 6 0.1 g of granular carrier for LHC deter-mination into a 29.6-mL glass bottle.6.2 From a buret, add a suitable fluid as follows: 0.5-mLincrements until 2.0 mL is reached, or the carrier meets one endpoint condit

10、ion. Shake between increments by hand or me-chanical shaker until completely absorbed. (A few sharp tapswith the heel of the hand may be necessary to break up asaturated portion.) Shaking should not exceed 2 min.6.3 After the first 2.0 mL is added or one end pointcondition is met, decrease the incre

11、ments to 0.2 mL andproceed as described in 6.2 until the end point is reached. Theend point is indicated by two or more of the following:6.3.1 Carrier darkens or appears wet.6.3.2 Granules cease to be free flowing.6.3.3 Granules stick to sides of bottle.6.3.4 Granules stick to bottom of bottle when

12、invertedslowly.6.4 An alternate procedure is to use 50 g of carrier. Followthe instructions given in 6.1-6.3, but use the 236.8-mL jar. Addan initial 15 mL of fluid in 5-mL increments, as described in6.2. Thereafter, follow the steps outlined in 6.3.6.5 For carriers with low LHC the initial incremen

13、ts of fluidadded may have to be adjusted down so the end points are notexceeded.7. Calculation7.1 Calculate % LHC as follows:% LHC 5ml fluid!3fluid specific gravity!3100!g granules!1ml fluid!3fluid Specific gravity!(1)1This test method is under the jurisdiction of ASTM Committee E35 onPesticides and

14、 Alternative Control Agents and is the direct responsibility ofSubcommittee E35.22 on Pesticide Formulations and Delivery Systems.Current edition approved Nov. 1, 2006. Published November 2006. Originallyapproved in 1992. Last previous edition approved in 2001 as E 1521 01.1Copyright ASTM Internatio

15、nal, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 Round the % LHC to the nearest whole number.8. Disposal of Sample8.1 Store all materials in a safe manner after testing, anddispose of used material in accordance with the product labeldirections and materia

16、l safety data sheet.9. Keywords9.1 formulations; granular carriers; liquid holding capacity;pesticidesASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that de

17、termination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved

18、or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel t

19、hat your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).E 1521 01 (2006)2

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1