ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf

上传人:diecharacter305 文档编号:529181 上传时间:2018-12-05 格式:PDF 页数:14 大小:669.58KB
下载 相关 举报
ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf_第1页
第1页 / 共14页
ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf_第2页
第2页 / 共14页
ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf_第3页
第3页 / 共14页
ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf_第4页
第4页 / 共14页
ASTM E1667-1995a(2012) Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants 《办公设施关于公众和居住者图像的适用性标准分类》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E1667 95a (Reapproved 2012)An American National StandardStandard Classification forServiceability of an Office Facility for Image to the Publicand Occupants1, 2This standard is issued under the fixed designation E1667; the number immediately following the designation indicates the year

2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classifyin

3、gan aspect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments for image to the public and occupants.1.2 Within that aspect of serviceability, each pair of scales,shown in Figs. 1-7, are for classifying one topic of service

4、abil-ity. Each paragraph in an Occupant Requirement Scale (seeFigs. 1-7) summarizes one level of serviceability on that topic,which occupants might require. The matching entry in theFacility Rating Scale (see Figs. 1-7) is a translation of therequirement into a description of certain features of a f

5、acilitywhich, taken in combination, indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-7)are indicative and not comprehensive. They are for quickscanning to estimate approximately, quickly, and economically,how

6、well an office facility is likely to meet the needs of one oranother type of occupant group over time. The entries are notfor measuring, knowing, or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level ofserviceability of an existing facility. It c

7、an also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability bu

8、t does not statehow to conduct a serviceability rating nor how to assign aserviceability score. That information is found in PracticeE1334. The scales in this classification are complimentary toand compatible with Practice E1334. Each requires the other.2. Referenced Documents2.1 ASTM Standards:3E63

9、1 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Buildingor Building-Related FacilityE1679 Practice for Setting the Requirements for the Ser-viceability of a Building or Building-Related Facility2.2 ISO Document:4ISO 6240 International Standard, Performance St

10、andards inBuildingContents and Presentation3. Terminology3.1 Definitions:3.1.1 facilitya physical setting used to serve a specificpurpose. E6313.1.1.1 DiscussionA facility may be within a building, awhole building, or a building with its site and surroundingenvironment; or it may be a construction t

11、hat is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orrequired to be used. E6313.1.2.1 DiscussionThe scope of this performance is of thefacility as a system

12、, including its subsystems, components andmaterials and their interactions, such as acoustical, hydrother-mal, air purity, and economic; and of the relative importance ofeach performance requirement).3.1.3 offcea place, such as a room, suite, or building, inwhich business, clerical or professional a

13、ctivities are con-ducted. E6311This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved April 1, 2012. Published May 2012. Originallyapproved in 199

14、5. Last previous edition approved in 2005 as E1667 95a (2005).DOI: 10.1520/E1667-95AR12.2Portions of this document are based on material originally prepared by theInternational Centre for Facilities (ICF) and r 1993 by ICF and Minister of PublicWorks and Government Services Canada. Their cooperation

15、 in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Availabl

16、e from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.4 For standard definitions of additional terms applicableto thi

17、s classification, see Terminology E631.4. Significance and Use4.1 Each Facility Rating Scale (see Figs. 1-7) in thisclassification provides a means to estimate the level of service-ability of a building or facility for one topic of serviceabilityand to compare that level against the level of any oth

18、er buildingor facility.4.2 This classification can be used for comparing how welldifferent buildings or facilities meet a particular requirementfor serviceability. It is applicable despite differences such aslocation, structure, mechanical systems, age, and buildingshape.4.3 This classification can

19、be used to estimate the amount ofvariance of serviceability from target or from requirement fora single office facility or within a group of office facilities.4.4 This classification can be used to estimate the following:4.4.1 Serviceability of an existing facility for uses otherthan its present use

20、.4.4.2 Serviceability (potential) of a facility that has beenplanned but not yet built.4.4.3 Serviceability (potential) of a facility for which re-modeling has been planned.4.5 Use of this classification does not result in buildingevaluation or diagnosis. Building evaluation or diagnosisgenerally re

21、quires a special expertise in building engineering ortechnology and the use of instruments, tools, or measurements.4.6 This classification applies only to facilities that arebuilding constructions, or parts thereof. (While this classifica-tion may be useful in rating the serviceability of facilities

22、 thatare not building constructions, such facilities are outside thescope of this classification.)4.7 This classification is not intended for, and is not suitablefor, use for regulatory purposes, nor for fire hazard assessmentnor for fire risk assessment.5. Basis of Classification5.1 The scales in F

23、igs. 1-7 contain the basis for classifica-tion.5.2 Instructions for the use of this classification are con-tained in Practices E1334 and E1679.6. Keywords6.1 appearance of building; exterior; building; facility; fa-cility occupants; function; image; to public and occupants;office; offices; appearanc

24、e of; performance; rating; rating scale;requirements; signage (in buildings); image of; serviceabilityE1667 95a (2012)2FIG. 1 Scale A.11.1 for Exterior AppearanceE1667 95a (2012)3FIG. 1 Scale A.11.1 for Exterior Appearance (continued)E1667 95a (2012)4FIG. 2 Scale A.11.2 for Public Lobby of BuildingE

25、1667 95a (2012)5FIG. 2 Scale A.11.2 for Public Lobby of Building (continued)E1667 95a (2012)6FIG. 3 Scale A.11.3 for Public Spaces Within the BuildingE1667 95a (2012)7FIG. 3 Scale A.11.3 for Public Spaces Within the Building (continued)E1667 95a (2012)8FIG. 4 Scale A.11.4 for Appearance and Spacious

26、ness of Office SpacesE1667 95a (2012)9FIG. 5 Scale A.11.5 for Finishes and Materials in Office SpacesE1667 95a (2012)10FIG. 6 Scale A.11.6 for Identity Outside the BuildingE1667 95a (2012)11FIG. 6 Scale A.11.6 for Identity Outside the Building (continued)E1667 95a (2012)12FIG. 7 Scale A.11.7 for Nei

27、ghborhood and SiteE1667 95a (2012)13FIG. 7 Scale A.11.7 for Neighborhood and Site (continued)ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determinati

28、on of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdr

29、awn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your

30、comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single

31、 or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).E1667 95a (2012)14