ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf

上传人:confusegate185 文档编号:532626 上传时间:2018-12-05 格式:PDF 页数:5 大小:170.79KB
下载 相关 举报
ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf_第1页
第1页 / 共5页
ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf_第2页
第2页 / 共5页
ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf_第3页
第3页 / 共5页
ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf_第4页
第4页 / 共5页
ASTM F377-2003(2015) Standard Practice for Calibration of Braking Tractive Measuring Devices for Testing Tires《校准试验轮胎制动 牵引力测量装置的标准实施规程》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F377 03 (Reapproved 2015)Standard Practice forCalibration of Braking/Tractive Measuring Devices forTesting Tires1This standard is issued under the fixed designation F377; the number immediately following the designation indicates the year of originaladoption or, in the case of revision,

2、 the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice gives procedures for the calibration of:reference load cellscalibration platform systems by

3、 using a reference load cellstatic calibration of braking/tractive force on locked wheelsof tire test trailers, instrumented vehicles, and laboratory tiretesting machines by using the calibration platform system as acalibration fixture.1.2 The values stated in SI units are to be regarded asstandard.

4、 The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of

5、 regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E74 Practice of Calibration of Force-Measuring Instrumentsfor Verifying the Force Indication of Testing MachinesF538 Terminology Relating to the Characteristics and Per-formance of Tires3. Terminology3.1 Definitions:3.1.

6、1 bias, nthe difference between the average measuredtest result and the accepted reference value; it measures in aninverse manner the accuracy of a test.3.1.2 longitudinal force, F, of a tire, nthe component ofthe tire force vector in the X direction.3.1.3 vertical load, nthe normal reaction of the

7、tire on theroad which is equal to the negative of normal force.4. Summary of Practice4.1 Reference-load cells shall be calibrated using proce-dures and equipment traceable to the National Institute ofStandards and Technology (NIST), or appropriate nationalstandards organization.NOTE 1Practice E74 ma

8、y be used as an alternative method forload-cell calibration.4.2 The calibrated reference-load cell is used to calibrate thecalibration-platform systems or used as the longitudinal forcesensor. The tire test trailer, instrumented vehicle, or laboratorytire testing machine is calibrated with the platf

9、orm.5. Significance and Use5.1 Calibration is essential in the use of various test plat-forms and devices to insure that the test results generated bythese test devices are accurate, repeatable and meaningful. Thisstandard gives the necessary instructions for the calibration ofall of the test device

10、s cited in the Scope.6. Apparatus6.1 The calibration system consists of the following basiccomponents:6.1.1 PlatformThe platform on which the test wheel isplaced shall have a flat high friction top surface. The platformshall be of sufficient dimensions to support the entire tirecontact patch through

11、out the calibration process. A low frictionbearing (an air bearing is recommended) permitting freehorizontal motion and capable of sustaining a vertical loadequal to the largest anticipated wheel load shall support theplatform. The longitudinal movement shall be sufficient toobtain the necessary req

12、uired force levels. The platform mayalso be instrumented with integrated transducers (Force Sen-sors) to measure vertical and longitudinal forces.6.1.2 Force Generation ApparatusA system, capable ofdeveloping a longitudinal force sufficient for the calibration ofthe operating range of the device, sh

13、all be used. The force shallbe applied along the longitudinal centerline of the platform.6.1.3 Force SensorsSensors to measure applied forces inthe vertical and longitudinal directions that shall be used tocalibrate braking/tractive measuring devices. These sensorscan be integrated force transducers

14、 located in the platform,scales or tension load cells. Sensors shall have sufficient1This practice is under the jurisdiction of ASTM Committee F09 on Tires and isthe direct responsibility of Subcommittee F09.10 on Equipment, Facilities andCalibration.Current edition approved June 1, 2015. Published

15、September 2015. Originallyapproved in 1974. Last previous edition approved in 2009 as F377 03 (2009).DOI: 10.1520/F0377-03R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,

16、 refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1measurement range to cover the maximum anticipated testwheel forces. Sensors shall be mounted in a manner such thatcross-

17、axis forces will not adversely affect the accuracy. Theforce sensor instrumentation shall have the capability to allowfor the recording of data, such as a chart recorder, data logger,or visual output that allows for manual logging of data.6.1.4 Reference Load CellThe force standard that pro-vides di

18、rect traceability to NIST or appropriate national stan-dards organization that shall be used to certify other forcesensors or weights used within this standard. If integratedplatform transducers are not used, the reference load cell maybe used as the longitudinal force sensor during calibration ofth

19、e braking/tractive measuring device. The reference load cellshall have sufficient measurement range to cover the maximumanticipated forces.7. Calibration of the Reference Load Cell and ForceSensors7.1 Three procedures are covered: (1) calibration of thereference-load cell, (2) calibration of the lon

20、gitudinal forcesensor, and (3) calibration of the vertical load sensor. Repeatthe appropriate calibrations when any relevant component ischanged or altered (see ASTM Manual 7). Repeat the calibra-tions annually unless the changes between the most recentcalibration equation values and those from the

21、previous cali-bration do not exceed 0.1%. Calibration intervals may belengthened to a maximum of 2 years provided that thesechanges do not exceed 0.1% of the value. Record the ambienttemperature during load cell calibrations. Force sensor gainvalues (or their equivalent) shall be consistent througho

22、utsections 7.3 and 7.4.7.2 Reference Load Calibration:7.2.1 Set up the reference load cell, indicator and requiredequipment to perform the calibration. List all equipment used,including signal conditioning and output devices. Recordequipment identification and calibration dates.7.2.2 Set the bridge-

23、excitation voltage and gain, or itsequivalent, in accordance with the instructions on the unitbeing used.7.2.3 Adjust the “bridge zero,“ or its equivalent, to “zero.“Be certain that the reference load cell is not being stressed.7.2.4 Using force measuring instruments or weights knownto 0.01% or bett

24、er of applied force, perform a calibration on thereference load cell. Class F weights of 8.9N (2 lb) or greaterhave a tolerance of 0.01%. Apply the calibration forces in atleast 8 appropriately spaced increments to a maximum of notless than the anticipated maximum force seen in use. Allow allforce i

25、ndicators to come to rest at each increment and recordthe force readings.7.2.5 Determine bias values at each applied force.7.2.6 The biases of the reference-load cell and indicatorsystem shall be 0.25% or less of the known applied force(minimum of 62.2N(60.5lbf).7.3 Calibration of Longitudinal Force

26、 Sensor Fig.1Subsection 7.3 does not apply when the reference load cellis used as the longitudinal force sensor during calibration of thebraking/tractive measuring device.7.3.1 Mount the reference-load cell such that its longitudi-nal axis is parallel to the direction of motion of the platformwithin

27、 62 and in line with the applied force. If necessary,place a tension spring in the longitudinal force applicationsystem to allow for longitudinal motion.7.3.2 Apply sufficient force to both channels of the systemthrough the full range of expected calibration forces to exerciseto platform. Release al

28、l forces.7.3.3 Set the bridge-excitation voltage and gain, or itsequivalent, for all instrumentation in accordance with theinstructions on the unit being used.7.3.4 Adjust the “bridge zeros,” or its equivalent, to “zero”on all instrumentation. Be certain that the reference load celland platform are

29、not being stressed.7.3.5 Using weights known to 0.1% of applied load orbetter, apply a test load, representative of a load which will beencountered on the braking/tractive test device to be calibrated,to the top of the platform near the geometric center of the top.The platform must be maintained lev

30、el within 60.25 duringcalibration. Record all force readings.NOTE 2The platform may be sensitive to the support structure usedduring calibration. Therefore during calibration, the platform shall besupported in a manner similar to that which will subsequently be usedduring the calibration of the brak

31、ing/tractive measuring device.7.3.6 Apply the longitudinal calibration force in at least 6approximately equally spaced increments to a maximum of notless than the anticipated maximum longitudinal wheel forceseen in use. Allow all force indicators to come to rest at eachincrement and record the force

32、 readings.7.3.7 Repeat 7.3.3 and 7.3.6 as necessary to collect at least12 calibration points.7.3.8 Determine longitudinal force bias values at eachapplied force.FIG. 1 Force Calibration of a Platform Force TransducerF377 03 (2015)27.3.9 The biases of the longitudinal force sensor and indi-cator syst

33、em shall be 1.0 % or less of the applied force and 0.5% or less than the maximum applied force (minimum of 0.1%of anticipated maximum braking/tractive measuring device testforce or 4.4 N (1lbf) whichever is greater).7.3.10 Determine cross talk of longitudinal force, read aspart of the vertical load

34、at each applied longitudinal force. Thebias of the vertical load sensor and indicator system at eachapplied longitudinal force shall be 61.0 % or less (minimum of64.4N(61lbf) of the applied vertical load.7.4 Calibration of Vertical Load Sensor:7.4.1 Level the vertical load sensor (platform with inte

35、graltransducers or appropriate scale) within 60.25.7.4.2 Set the bridge-excitation voltage and gain, or itsequivalent, for all instrumentation in accordance with theinstructions on the unit being used. Use gain values (or theirequivalent) from 7.3.3 if a two-axis platform with integraltransducers is

36、 utilized.7.4.3 Adjust the “bridge zeros,” or its equivalent, to “zero”on all instrumentation. Be certain that the platform or scale isnot being stressed.7.4.4 Using force measuring instruments or weights knownto 0.1 % of applied load or better, apply the vertical calibrationforce to the top of the

37、platform/scale near the geometric centerof the top in at least six approximately equally spacedincrements. The platform/scale shall be maintained levelwithin 60.25 during calibration. Begin at a load less than theminimum test load of the braking/tractive measuring deviceand continue to a load greate

38、r than or equal to the anticipatedmaximum wheel load. Allow all force indicators to come torest at each increment and record all force readings.NOTE 3The platform may be sensitive to the support structure usedduring calibration. Therefore during calibration, the platform shall besupported in a manne

39、r similar to that which will subsequently be usedduring the calibration of the braking/tractive measuring device.7.4.5 Repeat 7.4.1 through 7.4.4 as necessary to collect atleast 12 calibration points.7.4.6 Determine vertical load bias values at each appliedforce.7.4.7 The biases of the vertical sens

40、or and indicator systemshall be 1.0 % or less of the applied force and 0.5 % or less thanthe maximum applied force (minimum of 0.1% of anticipatedmaximum braking/tractive measuring device test force or 4.4 N(1lbf) whichever is greater).7.4.8 Determine cross talk of vertical load, read as part ofthe

41、longitudinal force at each applied vertical load. The bias ofthe longitudinal force sensor and indicator system at eachapplied vertical load shall be 61.0 % or less (minimum of64.4N(61lbf) of the applied longitudinal force.8. Calibration of Braking/Tractive Force on a LockedWheel (Fig. 2, Fig. 3,orF

42、ig. 4)8.1 Three procedures are covered: (1) for vertical calibra-tion of the test wheel load cell, (2) for longitudinal drivingtractive force calibration of the test wheel load cell, and (3) aprocedure identical to (2) above except for direction of theapplied force, ie. for the longitudinal braking

43、force calibrationof the test wheel load cell. Repeat the appropriate calibrationswhen any relevant component is changed or altered (seeASTMManual 7). At a minimum, repeat the calibrations annually.Record the ambient temperature during load cell calibrations.Force sensor gain values (or their equival

44、ent) must be consis-tent throughout sections 8.3 and 8.4.8.2 Equipment Preparation:8.2.1 Prior to starting calibration verify all reference equip-ment is in calibration in accordance with Section 6. List allequipment used, both test vehicle and reference forcemeasurement, signal conditioning and out

45、put devices. Recordequipment identification and calibration dates.8.2.2 Turn on the test vehicle system instrumentation andcalibration system instrumentation suitably in advance to allowwarm-up before attempting calibration.FIG. 2 Force Calibration of a Locked WheelF377 03 (2015)38.2.3 If necessary,

46、 clean the low friction bearing or airbearing plate surface to allow for free movement of theplatform.8.2.4 Position the test wheel over the platform such that thetest wheel is located as near as possible to the geometric centerof the platform throughout each calibration procedure. Ifnecessary, to m

47、aintain normal vehicle orientation and toprevent movement, place blocks with a high friction surfaceunder the other vehicle wheels so that the test wheel mountingface is perpendicular to level within 1. In the case of a trailer,the hitch point should be externally secured by a fixture or bythe tow v

48、ehicle. If the tow vehicle is used, engage the brakesand block the wheels to prevent slippage.8.2.5 Level the platform to within 0.25 and align it laterallywithin 3 of the trailer or vehicle longitudinal axis along thecenterline of the test wheel. Maintain platform level throughoutall calibration pr

49、ocedures.8.3 Vertical Calibration Procedure:8.3.1 Ensure the system force sensors are not stressed bylifting the test wheel from the calibration platform. Verify thatthe test wheel is locked/unlocked from rotation as appropriateto the test device. The suspension may be further unloaded bytapping the test wheel with a mallet. Adjust the zeros/gains ofall systems.8.3.2 Start the data-logging device and lower the test wheelonto the platform. Increase the load in no less than fourincrements until the full weight (not less than the anticipatedmaximum test load)

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2936-2013 Standard Guide for Contractor Self Assessment for U S Government Property Management Systems《美国政府物业管理系统承包商自我评估的标准指南》.pdf ASTM E2936-2013 Standard Guide for Contractor Self Assessment for U S Government Property Management Systems《美国政府物业管理系统承包商自我评估的标准指南》.pdf
  • ASTM E2937-2013 Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations《鉴识涂料检查中使用红外光谱的标准指南》.pdf ASTM E2937-2013 Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations《鉴识涂料检查中使用红外光谱的标准指南》.pdf
  • ASTM E2937-2018 Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations《在法医检验中使用红外光谱的标准指南》.pdf ASTM E2937-2018 Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations《在法医检验中使用红外光谱的标准指南》.pdf
  • ASTM E2938-2015 Standard Test Method for Evaluating the Relative-Range Measurement Performance of 3D Imaging Systems in the Medium Range《评估中等范围3D成像系统的相对范围测量性能的标准试验方法》.pdf ASTM E2938-2015 Standard Test Method for Evaluating the Relative-Range Measurement Performance of 3D Imaging Systems in the Medium Range《评估中等范围3D成像系统的相对范围测量性能的标准试验方法》.pdf
  • ASTM E2939-2013 Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems《测定光伏非聚光器系统用报告条件和预测能力的标准实施规程》.pdf ASTM E2939-2013 Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems《测定光伏非聚光器系统用报告条件和预测能力的标准实施规程》.pdf
  • ASTM E2939-2013(2018) Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems《确定光伏非集中器系统报告条件和预期容量的标准实施规程》.pdf ASTM E2939-2013(2018) Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems《确定光伏非集中器系统报告条件和预期容量的标准实施规程》.pdf
  • ASTM E2941-2013 Standard Practice for Nitric Acid-Extraction of Elements from Ores and Related Metallurgical Materials by Closed Vessel Microwave Heating《通过封闭容器微波加热硝酸萃取矿石和相关冶金材料元素的.pdf ASTM E2941-2013 Standard Practice for Nitric Acid-Extraction of Elements from Ores and Related Metallurgical Materials by Closed Vessel Microwave Heating《通过封闭容器微波加热硝酸萃取矿石和相关冶金材料元素的.pdf
  • ASTM E2941-2014 Standard Practices for Extraction of Elements from Ores and Related Metallurgical Materials by Acid Digestion《采用酸分解法从矿石和相关冶金材料中萃取元素的标准实践规程》.pdf ASTM E2941-2014 Standard Practices for Extraction of Elements from Ores and Related Metallurgical Materials by Acid Digestion《采用酸分解法从矿石和相关冶金材料中萃取元素的标准实践规程》.pdf
  • ASTM E2942-2015 Standard Guide for Security of Tank Farm Installations for Compliance with Spill Prevention Control and Countermeasure Plan (SPCC) Regulations《为使与泄露预防 控制和对策方案 (SPCC.pdf ASTM E2942-2015 Standard Guide for Security of Tank Farm Installations for Compliance with Spill Prevention Control and Countermeasure Plan (SPCC) Regulations《为使与泄露预防 控制和对策方案 (SPCC.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1