1、Designation: E 433 71 (Reapproved 2008)Standard Reference Photographs forLiquid Penetrant Inspection1This standard is issued under the fixed designation E 433; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These reference photographs are supplied as a means ofestablishing types and characteristics of surface discontinuitiesdetectable
3、 by the penetrant examination methods. They may beused as a reference for acceptance standards, specifications anddrawings.1.2 Actual dimensions including maximum length of indi-cations and number of indications per unit area must bespecified by the users of this document. No attempt has beenmade to
4、 establish limits of acceptability or the metallurgicalcause of a discontinuity.NOTE 1Examples of these reference photographs are shown in Figs.1-8.2. Referenced Documents2.1 ASTM Standards:2E 165 Test Method for Liquid Penetrant Examination2.2 ASTM Adjuncts:Reference Photographs for Penetrant Inspe
5、ction33. Classifications3.1 TypesFor the purposes of this standard there are twotypes of indications, which are defined as follows:3.1.1 Type I IndicationsThose in which neither of themeasurable dimensions is greater than three times the other.3.1.2 Type II IndicationsThose in which one of themeasur
6、able dimensions is at least three times greater than theother.3.2 ClassesFor purposes of this standard there are fourclasses of indications which are defined as follows:A. SingleB. Multiple unalignedC. Multiple alignedD. Intersection of surfaces (threads, corners, fillets, etc.)4. Identification4.1
7、The types of discontinuity indications covered by thesereference photographs are listed and described in Table 1. Eachtype of discontinuity indication is designated by a Romannumeral. The class of indication is designated by the letters Athrough D. Individual photographs within type and class areide
8、ntified by numbers. Each reference photograph is, therefore,identified with the proper Roman numeral, letter, and number.5. Method of Preparation5.1 The reference photographs were reproduced from mas-ter photographs which are the property of ASTM. The photo-graphs retain the original photographic co
9、ntrast.6. Basis for Use of Reference Photographs6.1 These reference photographs are intended for use whenspecified in the inquiry, contract, order material specification,or applicable code, and when the severity is mutually agreedupon between the manufacturer and the purchaser. It isrecognized that
10、it is impossible to rigidly interpret indicationsfrom a set of photographic references. Consequently, there is aneed for close cooperation between manufacturer and pur-chaser.6.2 Zones of inspection and severity levels in each zoneshall be shown on applicable drawings or otherwise specified.Unless o
11、therwise specified all accessible surfaces shall beexamined.6.3 These reference photographs are intended to depictpenetrant indications of surface discontinuities. They are notintended to indicate the depth of such discontinuities.1These reference photographs are under the jurisdiction of ASTM Commi
12、tteeE07 on Nondestructive Testing and are the direct responsibility of SubcommitteeE07.03 on Liquid Penetrant and Magnetic Particle Methods.Current edition approved Dec. 15, 2008. Published December 2008. Originallyapproved in 1971. Last previous edition approved in 2003 as E 433 71 (2003).2For refe
13、renced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM Headquarters. Order ADJE0433.TABLE 1 Reference Ph
14、otographs, Indication TypesType Class Description Fig. No.I A single I-A1, 2B multiple unaligned I-B1, 2, 3, 4C multiple aligned I-C1, 2D intersection of surfaces (threads, corners,fillets, etc.)I-D1II A single II-A1, 2, 3, 4B multiple unaligned II-B1, 2, 3C multiple aligned II-C1, 2, 3, 4D intersec
15、tion of surfaces (threads, corners, II-D1, 2, 3, 4, 5fillets, etc.)1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Applicable penetrant examination methods and tech-niques are described in the latest issue of Test Method E 165.7.
16、 Keywords7.1 discontinuities; liquid penetrant indications; liquid pen-etrant inspection; penetrant inspection; penetrant examination;photographs; reference photographsFIG. 1 Example of Type I, Class A, IndicationFIG. 2 Example of Type I, Class B, IndicationE 433 71 (2008)2FIG. 3 Example of Type I,
17、Class C, IndicationFIG. 4 Example of Type I, Class D, IndicationE 433 71 (2008)3FIG. 5 Example of Type II, Class A, IndicationFIG. 6 Example of Type II, Class B, IndicationE 433 71 (2008)4ASTM International takes no position respecting the validity of any patent rights asserted in connection with an
18、y item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical
19、 committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration a
20、t a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor
21、Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).FIG. 7 Example of Type II, Class C, IndicationFIG. 8 Example of Type II, Class D, IndicationE 433 71 (2008)5