ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf

上传人:diecharacter305 文档编号:533042 上传时间:2018-12-06 格式:PDF 页数:7 大小:114.89KB
下载 相关 举报
ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf_第1页
第1页 / 共7页
ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf_第2页
第2页 / 共7页
ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf_第3页
第3页 / 共7页
ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf_第4页
第4页 / 共7页
ASTM E562-2011 8125 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count《系统人工点计数法体积分数测定的标准试验方法》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E562 11Standard Test Method forDetermining Volume Fraction by Systematic Manual PointCount1This standard is issued under the fixed designation E562; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi

2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method may be used to determine the volume fraction of constituents in an opaquespecimen using a polished, planar cro

3、ss section by the manual point count procedure. The samemeasurements can be achieved using image analysis per Practice E1245.1. Scope1.1 This test method describes a systematic manual pointcounting procedure for statistically estimating the volumefraction of an identifiable constituent or phase from

4、 sectionsthrough the microstructure by means of a point grid.1.2 The use of automatic image analysis to determine thevolume fraction of constituents is described in Practice E1245.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstand

5、ard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenc

6、ed Documents2.1 ASTM Standards:2E3 Guide for Preparation of Metallographic SpecimensE7 Terminology Relating to MetallographyE407 Practice for Microetching Metals and AlloysE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1245 Practice for Determining t

7、he Inclusion or Second-Phase Constituent Content of Metals by Automatic ImageAnalysis3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology E7.3.2 Definitions of Terms Specific to This Standard:3.2.1 point countthe total number of points in a test gridthat fall

8、 within the microstructural feature of interest, or on thefeature boundary; for the latter, each test point on the boundaryis one half a point.3.2.2 point fractionthe ratio, usually expressed as a per-centage, of the point count of the phase or constituent ofinterest on the two-dimensional image of

9、an opaque specimento the number of grid points, which is averaged over n fields toproduce an unbiased estimate of the volume fraction of thephase or constituent.3.2.3 stereologythe methods developed to obtain informa-tion about the three-dimensional characteristics of microstruc-tures based upon mea

10、surements made on two-dimensionalsections through a solid material or their projection on asurface.3.2.4 test grida transparent sheet or eyepiece reticle witha regular pattern of lines or crosses that is superimposed overthe microstructural image for counting microstructural featuresof interest.3.2.

11、5 volume fractionthe total volume of a phase orconstituent per unit volume of specimen, generally expressedas a percentage.3.3 Symbols:PT= total number of points in the test grid.Pi= point count on the ithfield.1This test method is under the jurisdiction of ASTM Committee E04 onMetallography and is

12、the direct responsibility of Subcommittee E04.14 on Quanti-tative Metallography.Current edition approved Oct. 1, 2011. Published October 2011. Originallyapproved in 1976. Last previous edition approved in 2008 as E562 081. DOI:10.1520/E0562-11.2For referenced ASTM standards, visit the ASTM website,

13、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.PP

14、(i) =PiPT3 100 = percentage of grid points, in theconstituent observed on the ithfield.n = number of fields counted.Pp= 1n(i 5 1nPpi! = arithmetic average of Pp(i).s = estimate of the standard deviation (s) (see (Eq3) in Section 10).95 % CI = 95 % confidence interval= 6ts/=n (see Note 1).t = a multi

15、plier related to the number of fieldsexamined and used in conjunction with thestandard deviation of the measurements to de-termine the 95% CI.VV= volume fraction of the constituent or phaseexpressed as a percentage (see (Eq 5) in Section10).% RA = % relative accuracy, a measure of the statisticalpre

16、cision = (95 % CI/ Pp) 3 100.NOTE 1 Table 1 gives the appropriate multiplying factors (t) for anynumber of fields measured.4. Summary of Test Method4.1 Aclear plastic test grid or eyepiece reticle with a regulararray of test points is superimposed over the image, or aprojection of the image, produce

17、d by a light microscope,scanning electron microscope, or micrograph, and the numberof test points falling within the phase or constituent of interestare counted and divided by the total number of grid pointsyielding a point fraction, usually expressed as a percentage, forthat field. The average poin

18、t fraction for n measured fieldsgives an estimate of the volume fraction of the constituent. Thismethod is applicable only to bulk opaque planar sectionsviewed with reflected light or electrons.5. Significance and Use5.1 This test method is based upon the stereological prin-ciple that a grid with a

19、number of regularly arrayed points,when systematically placed over an image of a two-dimensional section through the microstructure, can provide,after a representative number of placements on different fields,an unbiased statistical estimation of the volume fraction of anidentifiable constituent or

20、phase (1, 2, 3).35.2 This test method has been described (4) as beingsuperior to other manual methods with regard to effort, bias,and simplicity.5.3 Any number of clearly distinguishable constituents orphases within a microstructure (or macrostructure) can becounted using the method. Thus, the metho

21、d can be applied toany type of solid material from which adequate two-dimensional sections can be prepared and observed.5.4 A condensed step-by-step guide for using the method isgiven in Annex A1.6. Apparatus6.1 Test Grid, consisting of a specified number of equallyspaced points formed by the inters

22、ection of very thin lines. Twocommon types of grids (circular or square array) are shown inFig. 1.6.1.1 The test grid can be in the form of a transparent sheetthat is superimposed upon the viewing screen for the measure-ment.6.1.2 Eyepiece Reticle, may be used to superimpose a testgrid upon the imag

23、e.6.2 Light Microscope, or other suitable device with aviewing screen at least 100 mm 3 125 mm, preferably withgraduated x and y stage translation controls, should be used toimage the microstructure.6.3 Scanning Electron Microscope, may also be used toimage the microstructure; however, relief due to

24、 polishing orheavy etching must be minimized or bias will be introduced asa result of deviation from a true two-dimensional sectionthrough the microstructure.6.4 Micrographs, of properly prepared opaque specimens,taken with any suitable imaging device, may be used providedthe fields are selected wit

25、hout bias and in sufficient quantity toproperly sample the microstructure.6.4.1 The applicable point counting grid shall only beapplied once to each micrograph. Point counting measurementsshould be completed on different fields of view and, therefore,different micrographs. Repeated point count measu

26、rements onan individual micrograph is not allowed.6.4.2 The magnification of the micrograph should be as highas needed to adequately resolve the microstructure withoutresulting in adjacent grid points overlaying a single constituentfeature.7. Sample Selection7.1 Samples selected for measurement of t

27、he phase orconstituent should be representative of the general microstruc-ture, or of the microstructure at a specified location within a lot,heat, or part.7.2 Adescription of the sample locations should be includedas a part of the results.3The boldface numbers in parentheses refer to the list of re

28、ferences at the end ofthis standard.TABLE 1 95 % Confidence Interval MultipliersNo. of Fields n t No. of Fields n t5 2.776 19 2.1016 2.571 20 2.0937 2.447 21 2.0868 2.365 22 2.0809 2.306 23 2.07410 2.262 24 2.06911 2.228 25 2.06412 2.201 26 2.06013 2.179 27 2.05614 2.160 28 2.05215 2.145 29 2.04816

29、2.131 30 2.04517 2.120 40 2.02018 2.110 60 2.000 1.960E562 1127.3 Any orientation of the prepared section (that is, whetherlongitudinal or transverse) can be used. However, it should berecorded since it may have an effect upon the precisionobtained.7.4 If the sample microstructure contains gradients

30、 or inho-mogeneities (for example, banding) then the section shouldcontain or show the gradient or inhomogeneity.8. Sample Preparation8.1 The two-dimensional sections should be prepared usingstandard metallographic, ceramographic, or other polishingprocedures, such as described in Methods E3.8.2 Sme

31、aring or other distortions of the phases or constitu-ents during preparation of the section or sections should beminimized because they tend to introduce an unknown biasinto the statistical volume fraction estimate.8.3 Etching of the sections, as described in Test MethodsE407, should be as shallow (

32、that is, light) as possible becausedeviations from a planar two-dimensional section will cause abias toward over estimation of the volume fraction.8.4 Stain- or coloring-type etchants are preferable to thosethat cause attack of one or more of the constituents or phases.8.5 Description of the etchant

33、 and etching procedure shouldbe included in the report.8.6 If etching is used to provide contrast or distinguishabil-ity of constituents then the volume fraction estimates should beobtained as a function of etching time to check the significanceof any bias introduced.9. Procedure9.1 Principle:9.1.1

34、An array of points formed by a grid of lines or curvesis superimposed upon a magnified image (that is, a field ofview) of a metallographic specimen.9.1.2 The number of points falling within the microstruc-tural constituent of interest is counted and averaged for aselected number of fields.9.1.3 This

35、 average number of points expressed as a percent-age of the total number of points in the array (PT)isanunbiased statistical estimation of the volume percent of themicrostructural constituent of interest.9.1.4 Acondensed step-by-step description of the procedureis provided in Annex A1.9.2 Grid Selec

36、tion:9.2.1 The grid should consist of equally spaced pointsformed by the intersection of fine lines. Diagrams of twopossible grids, one with a circular pattern and one with a squarepattern, which are recommended for use, are shown in Fig. 1.9.2.2 Determine the number of points (that is, the grid siz

37、e,PT) from a visual estimate of the area fraction occupied by theconstituent of interest. Table 2 provides guidelines for thisselection. The values in Table 2 do not correspond to theoreti-cal constraints; but, by using these values, empirical observa-tions have shown that the method is optimized fo

38、r a givenprecision.9.2.2.1 The user may choose to employ a 100 point gridover the entire range of volume fractions. The use of 100pointgrid facilitates easy volume percent calculations. the use ofCircular GridSquare GridNOTE 1The entire 24 points can be used, or the outer 16, or the inner8 points.FI

39、G. 1 Examples of Possible Grid Configurations That Can BeUtilizedTABLE 2 Guidelines for Grid Size SelectionANOTE 1A grid size selection which gives a significant number offields having no grid points on the constituent of interest should beavoided.Visual Area Fraction EstimateExpressed as a Percenta

40、geGrid Size (Number of Points, PT)2to5% 1005to10% 4910 to 20 % 2520 % 16AThese guidelines represent an optimum for efficiency for the time spentcounting and for the statistical information obtained per grid placement.E562 113only one overlay or eyepiece reticle for all volume percentdeterminations m

41、ay save both time and money.9.2.2.2 For constituents present in amount of less than 2%,a 400point grid may be used.9.2.3 Superimpose the grid, in the form of a transparency,upon a ground glass screen on which the section image isprojected.9.2.4 A grid in the form of an eyepiece reticle may also beus

42、ed.9.2.5 If the constituent areas form a regular or periodicpattern on the section image, avoid the use of a grid having asimilar pattern.9.3 Magnification Selection:9.3.1 Select the magnification so that it is as high as neededto clearly resolve the microstructure without causing adjacentgrid point

43、s to fall over the same constituent feature.9.3.2 As a guideline, choose a magnification that gives anaverage constituent size that is approximately one half of thegrid spacing.9.3.3 As the magnification is increased, the field areadecreases, and the field-to-field variability increases, thusrequiri

44、ng a greater number of fields to obtain the same degreeof measurement precision.9.4 Counting:9.4.1 Count and record for each field the number of pointsfalling on the constituent of interest.9.4.2 Count any points falling on the constituent boundaryas one half.9.4.3 In order to minimize bias, any poi

45、nt that is doubtful asto whether it is inside or outside of the constituent boundaryshould be counted as one half.9.4.4PPi!5Pi3 100PT(1)9.4.5 The values of PP(i)are used to calculate Ppandstandard deviation, s.9.5 Selection of the Number of Fields:9.5.1 The number of fields or images to measure depe

46、nds onthe desired degree of precision for the measurement. Table 3gives a guide to the number of fields or images to be countedas a function of PT, the selected relative accuracy (statisticalprecision), and the magnitude of the volume fraction.9.6 Selection of the Array of Fields:9.6.1 Use a uniform

47、ly spaced array of fields to obtain theestimated value, Pp, and the estimated standard deviation, s.9.6.2 If gradients or inhomogeneities are present, then auniform spacing of fields may introduce a bias into theestimate. If another method of field selection is used, forexample, random, then describ

48、e it in the report.9.6.3 When the microstructure shows a certain periodicityof distribution of the constituent or phase being measured, anycoincidence of the points of the grid and the structure must beavoided. This can be achieved by using either a circular grid ora square grid placed at an angle t

49、o the microstructuralperiodicity.9.7 Grid Positioning Over FieldsMake grid positioningof each field without viewing the microstructure to eliminateany possibility of operator bias. This can be accomplished bymoving the x and y stage mechanism a fixed amount whileshifting to the next field without looking at the microstructure.9.8 Improving Measurement Precision It is recommendedthat the user attempt to sample more of the microstructureeither by multiple specimens or by completely repeating themetallographic preparation on the same sample when theprecision for a

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1