ASTM E677-1994(2016) 1829 Standard Specification for Interchangeable Spherical Ground Joints《可互换球面磨口的标准规格》.pdf

上传人:王申宇 文档编号:533297 上传时间:2018-12-06 格式:PDF 页数:3 大小:102.42KB
下载 相关 举报
ASTM E677-1994(2016) 1829 Standard Specification for Interchangeable Spherical Ground Joints《可互换球面磨口的标准规格》.pdf_第1页
第1页 / 共3页
ASTM E677-1994(2016) 1829 Standard Specification for Interchangeable Spherical Ground Joints《可互换球面磨口的标准规格》.pdf_第2页
第2页 / 共3页
ASTM E677-1994(2016) 1829 Standard Specification for Interchangeable Spherical Ground Joints《可互换球面磨口的标准规格》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: E677 94 (Reapproved 2016)Standard Specification forInterchangeable Spherical Ground Joints1This standard is issued under the fixed designation E677; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi

2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers standard dimensional require-ments for obtaining, within practical limits, interchangeabilityin spher

3、ical ground joints for ordinary laboratory and industrialapplications. It covers dimensional interchangeability of theground surfaces only and does not involve design characteris-tics of the item except where specified, nor does it involvephysical or chemical characteristics of the material used.NOT

4、E 1The dimensions pertaining to spherical ground joints weretaken from the Commercial Standard CS 2158 of the U.S. Department ofCommerce.NOTE 2Although glass is the most commonly used material forground joints, other materials may be used as specified. Spherical jointsconstructed from glass shall co

5、nform to Specifications E438 and E671.1.2 The following precautionary caveat pertains only to theTest Method portion, Section 4, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this sta

6、ndard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory ApparatusE671 Specification for Maximum Permissible Thermal Re-sidual Stress in An

7、nealed Glass Laboratory ApparatusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Specification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United States Government Procure-mentsE1157 Specification for Samp

8、ling and Testing of ReusableLaboratory Glassware2.2 U.S. Department of Commerce Standard:CS 21 Interchangeable Taper-Ground Joints, Stopcocks,Stoppers, and Spherical-Ground Joints33. Requirements3.1 Socket MemberThe design of the socket member isshown in Fig. 1. The contour of the ground area shall

9、bespherical, with a radius of curvature equal to one half of thegaging ball diameter specified in Table 1 as a minimum. Thecontour of the shoulder shall be essentially spherical andconcentric with the ground area. When tested in accordancewith 4.2, socket members shall show a continuous circumfer-en

10、tial line of contact with the gaging ball.3.2 Ball MemberThe design of the ball member is shownin Fig. 1. The contour of the ground area shall be spherical,with a radius of curvature equal to one half of the gaging balldiameter as specified in Table 1 as a maximum. The contour ofthe shoulder shall b

11、e essentially spherical, approximatelyconcentric with the ground area and with a slightly smallerradius to provide a short offset at or slightly beyond the line ofthe gaging diameter. Ball members shall meet the reducedpressure test (4.3) when assembled with a socket membercomplying with 3.1.3.3 Siz

12、e DesignationThe size designation of joints shallbe the accepted nominal gaging diameter, plus the insidediameter of the joint within the ball member, both expressed inmillimetres and separated by a line. Therefore, the designation18/7 means that the nominal gaging diameter of the joint is 18mm and

13、the inside diameter of the joint is 7 mm.3.4 DimensionsThe size designations and essential di-mensions of joints are shown in Table 1. Only the sizes listedshall be considered standard.3.5 InterchangeabilityWhen assembled ball-and-socketmembers are paired at random and tested under reducedpressure,

14、the leak rates shall not exceed those specified in 4.3.4. Test Methods4.1 Gaging the BallGaging balls shall have dimensionsand tolerances shown in Table 1.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.0

15、1 onLaboratory Ware and Supplies.Current edition approved Sept. 1, 2016. Published September 2016. Originallyapproved in 1980. Last previous edition approved in 2004 as E677 94 (2010).DOI: 10.1520/E0677-94R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom

16、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Discontinued 1979U.S. Department of Commerce, Washington, DC 20234.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,

17、 PA 19428-2959. United States14.2 Gaging the SocketSockets shall be tested against agaging ball. The ball shall enter the socket and the line ofcontact shall be continuous circumferentially. This line may beobtained with the use of a film of Prussian blue or stopcockgrease applied to the gaging ball

18、.4.3 LeakageUse the leak test apparatus illustrated in Fig.2, or one functionally similar to it, with the average differentialpressure during the test kept above 600 mm Hg. Conduct thetest as follows:4.3.1 Clean both joints to be tested with distilled water, andthen dry them with a clean paper towel

19、. Next, wipe the groundzones with a clean chamois to remove any remaining particles.4.3.2 Tightly close the unground end of the joint to beconnected to the manometer system, using a rubber stoppercontaining a concentric hole (or rubber tubing, depending uponthe joint size under test) sized to fit sn

20、ugly on the manometerconnection, and mount the joint on the connection in an uprightposition.4.3.3 Firmly plug the unground end of the other type of jointwith a solid rubber stopper.4.3.4 Carefully mate the ground surfaces of the jointswithout exerting any pressure on them.4.3.5 Gently apply a 225-g

21、 weight on the upper joint forseating pressure; then rotate the upper joint 90 and remove theweight.4.3.6 After ensuring that the stopcock to the vacuum pumpis in the closed position, turn on the pump, and adjust thestopcock to the pump so that the mercury in the manometerrises to a level such that

22、the average differential pressure willremain above 600 mm Hg at the conclusion of the test.4.3.7 Allow air leakage to occur through the mated joints fora timed interval, and note the change in differential pressure.4.3.8 Repeat 4.3.4 4.3.7 once, ensuring in 4.3.5 that theupper joint is rotated 90 fr

23、om its position in the first test.4.3.9 CalculationCompute the leak rate in torrL/s orPaL/s as follows:Leak rate 5 P!V!/T (1)where:P = maximum change in differential pressure noted in test,mm Hg or Pa,V = total evacuated volume, including manometer tubing,connections, flask, and joints, L, andFIG. 1

24、 Diagram of Ball-and-Socket MembersTABLE 1 Spherical Ground JointsJoint SizeDesignationNominalGagingDiameter,mmDimensionD(approximate),mmGaging BallDiameter,mm7/1 7 1.0 7.144 0.00112/1 12 1.0 12.700 0.00312/1.5 12 1.5 12.700 0.00312/2 12 2.0 12.700 0.00312/3 12 3.0 12.700 0.00312/5 12 5.0 12.700 0.0

25、0318/7 18 7.0 19.050 0.00318/9 18 9.0 19.050 0.00328/12 28 12.0 28.575 0.00428/15 28 15.0 28.575 0.00435/20 35 20.0 34.925 0.00435/25 35 25.0 34.925 0.00440/25 40 25.0 41.275 0.00450/30 50 30.0 50.800 0.00465/40 65 40.0 63.500 0.00575/50 75 50.0 76.200 0.006102/75 102 75.0 101.600 0.008NOTE 1Evacuat

26、ed volume of manometer tubing, connections, andflask shall be 100 to 150 cm3. Joint volume shall be added for leak ratecalculation.NOTE 2Leak rate of apparatus shall not exceed 5 % of that of jointbeing tested. Spherical joints constructed from glass shall conform toSpecifications E438 and E671.NOTE

27、 3Dimensions are in millimetres and are approximate, exceptfor minimum diameters.FIG. 2 Schematic Representation of Leak Test ApparatusE677 94 (2016)2T = time of test, s.The leak rate shall not exceed the following values:Leak RateJoint Size torrL/s PaL/s7/1 to 12/5 0.15 20.018/7 to 28/15 0.30 39.93

28、5/20 to 75/50 0.45 59.8102/75 0.60 79.85. Marking5.1 Interchangeable spherical ground joints conforming tothis specification shall be marked on both members with thesymbol SJ indicating spherical joint, the size designation, andthe trademark of manufacturer or distributor. This symbol isthe manufact

29、urers assurance to purchasers that the itemidentified by the symbol is a standard interchangeable size andtype described and is manufactured within the tolerancespermitted by this specification. It shall not be used on joints norin advertising description of joints of any size or type otherthan thos

30、e described in this standard.6. Sampling and Testing6.1 For sampling and testing refer to Specification E1157.7. Packaging7.1 For packaging, select from Specifications E920 or E921or Practice E1133.8. Keywords8.1 ground; joints; sphericalASTM International takes no position respecting the validity o

31、f any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to

32、 revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters.

33、Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is c

34、opyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 94 (2016)3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1