ASTM F1363-2007(2011) Standard Guide for Reduction of Risk of Injury for Archery Overdraws《降低射箭运动员由于张拉过度而受伤风险的标准指南》.pdf

上传人:diecharacter305 文档编号:534752 上传时间:2018-12-06 格式:PDF 页数:3 大小:92.02KB
下载 相关 举报
ASTM F1363-2007(2011) Standard Guide for Reduction of Risk of Injury for Archery Overdraws《降低射箭运动员由于张拉过度而受伤风险的标准指南》.pdf_第1页
第1页 / 共3页
ASTM F1363-2007(2011) Standard Guide for Reduction of Risk of Injury for Archery Overdraws《降低射箭运动员由于张拉过度而受伤风险的标准指南》.pdf_第2页
第2页 / 共3页
ASTM F1363-2007(2011) Standard Guide for Reduction of Risk of Injury for Archery Overdraws《降低射箭运动员由于张拉过度而受伤风险的标准指南》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F1363 07 (Reapproved 2011)An American National StandardStandard Guide forReduction of Risk of Injury for Archery Overdraws1This standard is issued under the fixed designation F1363; the number immediately following the designation indicates the year oforiginal adoption or, in the case o

2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the function of archery overdraws andsuggests a limited number of geometric

3、configurations thatcould decrease the potential risk of injury to the archer.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ

4、ine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 acceptable overdrawan acceptable configuration ofan archery bow overdraw should provide partial or fullcontainment for the arrow if the arrow becomes disengagedfrom th

5、e arrow rest.2.1.2 archery overdrawany design configuration, integralor added, that permits the extreme forward tip of an arrow to bedrawn past the pivot point of the hand grip.3. Significance and Use3.1 This guide covers only the most obvious areas ofoverdraw safety.3.2 This guide is not intended a

6、s a comprehensive analysisof the subject.4. Arrow Containment4.1 Vertical Plane:4.1.1 In the vertical plane, Fig. 1 shows that increasinglevels of arrow enclosure will provide increasing levels ofarrow containment.4.1.2 A higher degree of arrow containment may beachieved by the position in Fig. 1(D)

7、 than by that in Fig. 1(A).4.2 Horizontal Plane:4.2.1 It must be recognized that an arrow can be drawn pastthe support of the arrow rest, regardless of the type of bow andwhether or not it has an overdraw. This condition is dependenton the length of the arrow and lies entirely within the controlof t

8、he individual archer. The length of the arrow must beselected so that the arrow will not be drawn past the arrow rest.It is generally possible, within functional limits, to providesome hardware design to further guard against the possiblehazard from negligence on the part of the user.4.2.2 The locat

9、ion of the arrow rest in relation to the aft endof overdraw is shown in Fig. 2.4.2.3 An arrow rest placed at the extreme aft end of theoverdraw (Fig. 2(A) may allow the arrow to fall off the restand overdraw platform if an archer draws past his or her drawlength.4.2.4 The arrow rest location at the

10、forward end of theplatform is shown in Fig. 2(C). In this location the arrowdisengagement from the rest should be contained by theplatform to a greater degree than in Fig. 2(A).4.3 Arrow Containment Methods Without Full Enclosure ofthe Arrow:4.3.1 A relatively wide horizontal plate extending beyondt

11、he wrist and knuckles of the bow hand may provide adequatearrow containment if the arrow disengages from the rest (Fig.3).1This guide is under the jurisdiction of ASTM Committee F08 on SportsEquipment and Facilities and is the direct responsibility of Subcommittee F08.16 onArchery Products.Current e

12、dition approved June 1, 2011. Published July 2011. Originally approvedin 1991. Last previous edition approved in 2007 as F1363 07. DOI: 10.1520/F1363-07R11.FIG. 1 Increasing Levels of Arrow Containment, Vertical Plane1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke

13、n, PA 19428-2959, United States.4.3.2 A relatively high vertical plate left of the arrow (for aright-handed archer) may provide adequate containment for anarrow raised upward from the arrow rest (Fig. 4).4.3.3 It should be noted that most overdraw designs are acombination of Figs. 3 and 4 to some ex

14、tent, and they providevarious degrees of arrow containment.5. Suggested Guidelines5.1 Vertical Plane:5.1.1 An open system with a relatively high vertical platecould provide adequate levels of arrow containment (Fig. 4),should the arrow become disengaged from the rest.5.1.2 A fully enclosed overdraw

15、system that surrounds thearrow would shelter the arrow circumferentially at all points inthe vertical plane (Fig. 5) and provide a still greater degree ofarrow containment.5.2 Horizontal Plane:5.2.1 In the horizontal plane (looking down on the archer),an arrow might be disengaged from the arrow rest

16、, even in afully vertically enclosed system.5.2.2 The length of an arrow overhanging in front of the restat full draw should be long enough to prevent disengagementof the arrow if the archer pulls past his or her draw length (Fig.6). On a compound bow, this distance may be made equal to orgreater th

17、an the maximum distance that the bow can bereasonably drawn. An extra-long arrow would give a greaterdegree of arrow containment.6. Overdraws on Bows without Draw Stops or DefinedValleys in the Force-Draw Characteristics6.1 Such bows can be drawn further than compound bowspast their recommended draw

18、 length. An adequate arrowoverhang for a compound bow may not be sufficient for arecurve bow.7. Alignment of Overdraws With Sight Window and BowShelf7.1 To minimize the possibility of arrow impact against thebowhandle, it is critical that the horizontal plate of theoverdraw be in line with or higher

19、 than the bow shelf. It is alsosuggested that the side plate be in line with or to the left of thesight window (for right-handed shooters) (Fig. 7).8. Instructions8.1 It is suggested that the manufacturer issue instructionswith each overdraw unit stating that the recommended lengthof overhang from t

20、he rest for an arrow is a minimum of oneinch.FIG. 2 Increasing Levels of Arrow Containment, Horizontal PlaneFIG. 3 Extended Width of the Horizontal PlateFIG. 4 Extended Height of the Vertical Plate FIG. 5 Fully Enclosed Overdraw SystemF1363 07 (2011)29. Keywords9.1 arrow; bow shelf; containment; ove

21、rdraw; sight windowASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement

22、of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for

23、 additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known

24、to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM a

25、t the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).FIG. 6 Adequate Overhang of the Arrow Relative to the RestFIG. 7 Alignment of OverdrawsF1363 07 (2011)3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1