ASTM F1365-1991(2013) Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性的标准.pdf

上传人:ownview251 文档编号:534759 上传时间:2018-12-06 格式:PDF 页数:3 大小:75.15KB
下载 相关 举报
ASTM F1365-1991(2013) Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性的标准.pdf_第1页
第1页 / 共3页
ASTM F1365-1991(2013) Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性的标准.pdf_第2页
第2页 / 共3页
ASTM F1365-1991(2013) Standard Test Method for Water Infiltration Resistance of Plastic Underground Conduit Joints Which Use Flexible Elastomeric Seals《采用柔性合成橡胶密封件的塑料地下管道接头耐水渗透性的标准.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F1365 91 (Reapproved 2013) An American National StandardStandard Test Method forWater Infiltration Resistance of Plastic UndergroundConduit Joints Which Use Flexible Elastomeric Seals1This standard is issued under the fixed designation F1365; the number immediately following the designa

2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the deter

3、mination of the waterinfiltration resistance of gasketed plastic underground conduitjoints using a pressurized water bladder apparatus.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided fo

4、r information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r

5、egulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsF512 Specification for Smooth-Wall Poly(Vinyl Chloride)(PVC) Conduit and Fittings for Under

6、ground Installation2.2 Underwriters Laboratories (UL) Standard:UL 651 Schedule 40 and 80 Rigid PVC Conduit32.3 National Electrical Manufacturers Association (NEMA)Standards:TC-2 Electrical Plastic Tubing (EPT) and Conduit (EPC-40and EPC-80)4TC-6 PVC and ABS Plastic Utilities Duct for UndergroundInst

7、allation4TC-8 Extra-Strength PVC Plastic Utilities Duct for Under-ground Installation43. Significance and Use3.1 Underground electrical and communication conduitshould be impervious to groundwater in order to preventdamage to conductors and utility vaults. The bladder testdescribed in this test meth

8、od may be used to qualify potentialgasketed conduit systems by indicating whether the jointsystem will prevent water infiltration.3.2 This test method can be used to qualify joints for plasticunderground conduits using flexible elastomeric seals.However, it should not be assumed that a joint system

9、thatpasses this test method will be able to seal under cases ofmisinstallation or abuse, or both.3.3 This test method covers all of the following gasketedconduit types: encased burial (EB) excluding EB20, directburial (DB), telecommunications, cable television, and Sched-ule 40 conduit and Schedule

10、80 conduit. Trade sizes coveredare 2-in. nominal size and larger. (See UL 651; NEMA TC-2,TC-6, and TC 8; and Specification F512.)3.4 This test method also covers fittings that are intended foruse with the conduit types described in 3.3 and which useflexible elastomeric seals.4. Apparatus4.1 GeneralO

11、ne type of bladder joint tester is shown inFig. 1.4.2 Bladder:4.2.1 The bladder shall be similar to that shown in Fig. 1.The bladder shall be comprised of a reinforced elastomerictube that is capable of providing a watertight capsule aroundthe subject joint specimen.4.2.2 The bladder shall be able t

12、o safely contain an internalwater pressure of at least 11.0 psi (75 kPa).4.2.3 The bladder shall have plumbing connections thatallow the bladder to be pressurized with water and that allowtrapped air to be bled out of the bladder.4.2.4 The bladder shall have a pressure gage that indicatespressure in

13、 the bladder. This gage shall be capable of measur-ing 11 psi (75 kPa) (gage) with an accuracy of 60.5 psi (63.5kPa) (gage).1This test method is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.40 on TestMethods.Current editio

14、n approved Aug. 1, 2013. Published October 2013. Originallyapproved in 1991. Last previous edition approved in 2009 as F1365 91(2009) DOI:10.1520/F1365-91R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of A

15、STMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories (UL), 333 Pfingsten Rd.,Northbrook, IL 60062-2096, http:/.4Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Ross

16、lyn, VA 22209, http:/www.nema.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 Support Fixture:4.3.1 The support fixture shall constrain movement of thetest specimen and bladder during testing.4.3.2 The support fixture shall be

17、 capable of axially deflect-ing the joint specimen about the joint to the maximumdeflection angle recommended by the joint manufacturer.NOTE 1Axial deflection of a gasketed pipe joint will also inducediametric deformation of the bell and spigot if the angle of axial deflectionis large enough. This c

18、an be beneficial when evaluating the sealing abilityof a gasketed pipe joint.5. Test Specimens5.1 The gasketed joint specimen shall be comprised of agasketed bell and a spigot with a chamfer on the outsidediameter edge. Both the bell and spigot shall be of sufficientlength to extend out beyond the b

19、ladder enough to provide ameans by which to attach the specimen/bladder assembly to thesupport fixture.5.2 Bell specifications and spigot chamfer specificationsshall be determined by the manufacturer, but the specimensshall be representative of normal and customary production bythe manufacturer. (Se

20、e Test Method D2122.)5.3 Three specimens shall be tested for each size of gas-keted conduit.6. Conditioning6.1 Condition specimens for at least2hinairatatemperature of 73.4 6 3.6F (23 6 2C) and conduct the testin a room maintained at the same temperature. (See PracticeD618.)7. Procedure7.1 Select an

21、d condition three sets of gasketed bells andspigots of the same nominal size according to Sections 5 and 6of this test method.7.2 Mark the specimens with consecutive numbers, startingwith “1” and ending with “3.”7.3 Select a bell/spigot pair and apply a joint lubricantrecommended by the conduit manu

22、facturer to both the bell andspigot according to the lubricant manufacturers directions.7.4 Insert the spigot into the bell until the insertion line onthe spigot is flush with the bell lip.7.5 Slide the bladder over the assembled conduit joint andcenter the bladder over the joint seam. Seal the ends

23、 of thebladder to the spigot and bell.NOTE 2The type of clamps used to seal the bladder to the specimenand the location of the clamps on the specimen may influence the amountof bell and spigot deformation when the joint is deflected axially.7.6 Attach all plumbing in accordance with 4.2.3 and 4.2.4t

24、o the bladder assembly.7.7 Attach the bladder/specimen assembly to the test fixturein a horizontal, axially straight position.7.8 Fill the bladder with water and bleed off trapped air. Donot allow the bladder to pressurize past 5 psi (34 kPa) duringthe filling and air bleeding of the bladder.7.9 Aft

25、er all air is bled from the bladder, pressurize thebladder to 11 psi (75 kPa) and allow the bladder pressure tostabilize for 5 min.7.10 After the stabilization period, make the necessaryadjustments to the bladder pressure to return it to 11.0 6 0.5psi (75 6 3.5 kPa).7.11 Check for water leakage insi

26、de specimen. Leakage atthis point constitutes failure of the test.7.12 Visually check for leakage of the joint at 5, 10, and15-min intervals. If leakage is detected at any interval, discon-tinue the test. Any leakage constitutes a failure of the test.7.13 If no leakage has occurred to this point, re

27、peat 7.12after axially misaligning the same joint to the maximumamount allowed by the joint manufacturer.7.14 Any leakage during any part of the test constitutesfailure of the test and the test may be suspended at that point.7.15 Repeat 7.3 through 7.14 for the remaining joints.7.16 If other sizes o

28、f conduit are to be tested, repeat 7.1through 7.15.8. Report8.1 Each test of a nominal size of conduit (three specimens)shall generate a test report.8.2 The test report shall include the following:8.2.1 Identification of the bell and spigot specimens used inthe test, including nominal size, type of

29、conduit, material ofmanufacture, type and source of gasket, and the name of thejoint manufacturer.FIG. 1 Bladder Test ApparatusF1365 91 (2013)28.2.2 Whether the joint passed or failed the test. If the jointfailed, state at what point in the test failure occurred.8.2.3 Date(s) of testing.8.2.4 Locati

30、on of testing.8.2.5 Name(s) of personnel conducting test.8.2.6 Comments, if appropriate.9. Precision and Bias9.1 No statement is made about either the precision or biasof this test method for determining water infiltration resistancesince the result merely states whether there is conformance tothe c

31、riteria for success specified in the procedure.10. Keywords10.1 bladder; gasketed conduit; underground conduit; waterinfiltrationASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard ar

32、e expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not

33、revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which yo

34、u may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United

35、 States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).F1365 91 (2013)3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1