ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf

上传人:eveningprove235 文档编号:535772 上传时间:2018-12-06 格式:PDF 页数:6 大小:404.33KB
下载 相关 举报
ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf_第1页
第1页 / 共6页
ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf_第2页
第2页 / 共6页
ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf_第3页
第3页 / 共6页
ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf_第4页
第4页 / 共6页
ASTM F1826-2000(2016) Standard Specification for Live Line and Measuring Telescoping Tools《带电测量伸缩工具的标准规格》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F1826 00 (Reapproved 2016)Standard Specification forLive Line and Measuring Telescoping Tools1This standard is issued under the fixed designation F1826; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last

2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers mechanical and electrical test-ing and acceptance criteria for telescoping live line tools.1.1.1

3、A tool designed only for use as a measuring deviceneed not comply with mechanical strength requirements of thisspecification.1.2 The use and maintenance of this equipment is beyondthe scope of this specification.1.3 This specification does not cover multiple section orextendable section clampsticks.

4、1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 The following safety hazards caveat pertains to Section9 only. This standard does

5、 not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stand

6、ards:2D149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesF819 Terminology Relating to Electrical Protective Equip-ment for Workers3. Terminology3.1 Definitions Terminology used in this specification isin acc

7、ordance with Definitions F819.3.2 Definitions of Terms Specific to This Standard:3.2.1 acceptance test, none made at the option of thepurchaser to verify that a product meets design criteria.3.2.2 design test, none made on a sample treated asrepresentative of an industrial product. These tests gener

8、allywill not be repeated in quantity production.3.2.3 dimensional check, nmeasurements made to verifythat a product complies with the dimension stated by themanufacturer.3.2.4 hydrophobic, adjlacking affinity for water.3.2.5 routine test, na type of test made regularly onproduction material.3.2.6 te

9、lescoping live line tool, nan extendable multiplesection FRP tool designed to carry an attachment to performmechanical tasks.3.2.7 telescoping measuring tool, nan extendable multiplesection FRP tool designed only to measure vertical heights.3.2.8 visual inspection, na visual check made to detectmanu

10、facturing defects.4. Significance and Use4.1 This specification shall be used for design, routine, andacceptance testing of live line and measuring telescoping tools.5. Ordering Information5.1 Include the following information when ordering tele-scoping live line or measuring tools, or both:5.1.1 Qu

11、antity.5.1.2 Catalog number.NOTE 1Live line tools may also be designed as a measuring tool.5.1.3 Tested to meet ASTM Specification F1826 designtests.6. Workmanship, Finish, and Appearance6.1 The external and internal surfaces shall have hydropho-bic abilities.6.2 The external and internal surfaces s

12、hall be free of anyabrasions, scratches, blemishes and surface defects that maycapture an impurity and impair the dielectric integrity of theproduct.1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSu

13、bcommittee F18.35 on Tools telescoping measuring toolsFIG. 11 Typical Test Arrangement for Electrical Withstand Acceptance TestTABLE 1 Telescoping Live Line Tool Horizontal BendingDeflection Test Acceptable Values of Deflection Versus ExtendedLengthExtended Length No Weight Added 2.27 kg (5 lb) Adde

14、d2.4m(8ft) 1.3cm(12 in.) 9.2 cm (358 in.)3.7m(12ft) 9cm(334 in.) 0.4m(1ft358 in.)4.9 m (16 ft) 26.7 cm (1012 in.) 0.9m(2ft1114 in.)6.0m(20ft) 0.53m(1ft9in.) 1.7m(5ft612 in.)7.6m(25ft) 0.95m(3ft112 in.) 2.4 m (8 ft 0 in.)9.1 m (30 ft) 1.5 m (5 ft 1 in.) 3.1 m (10 ft 1058 in.)10.7m(35ft) 2.3m(7ft7in.)

15、 4.4m(14ft4in.)12.2 m (40 ft) 3.15 m (10 ft 4 in.) 5.6 m (18 ft 4 in.)TABLE 2 Telescoping Live Line Tool Vertical Deflection Test (NoWeight Added)Extended Length No Weight Added2.4m(8ft) 0.53m(1ft9in.)3.7m(12ft) 0.83m(2ft812 in.)4.9m(16ft) 1.1m(3ft812 in.)6.1m(20ft) 1.6m(5ft412 in.)7.6m(25ft) 2.0m(6

16、ft8in.)9.1m(30ft) 2.5m(8ft2in.)10.7 m (35 ft) 3.1 m (10 ft 112 in.)12.2 m (40 ft) 3.7 m (12 ft 3 in.)TABLE 3 Moisture Conditioning ValuesTime: 168 hTemperature: 23 2CRelative humidity: 93 % or greaterTABLE 4 Leakage Current l1AType Outside Diameter Leakage Current l1mm in. ATube B025.4 01 525.431.8

17、1114 6 31.8 38.1 114 112 8 38.1 44.5 112 134 9 44.5 50.8 134 2 1050.863.5 2212 12 63.5 76.2 212 3 14AValues listed for maximum l1are based on pole constructed of a relatively thinwall and filled internally with foam or hollow tube. Some special applicationsrequire a thicker wall, denser foam, or dif

18、ferent materials, which could change thedielectric constant of the test setup and consequently l1. Tubes, such as these, willstill meet the requirements of this specification if the dry leakage is less than twicethe listed maximum value of l1in the table.B = one set not two.F1826 00 (2016)5APPENDIX(

19、Nonmandatory Information)X1. Alternative Electrical Withstand TestX1.1 The test apparatus shall be designed to provide theoperator full protection in the performance of duties andprovide reliable means of de-energizing and grounding thehigh voltage circuit.X1.2 The typical test set-up is shown in Fi

20、g. X1.1 and Fig.X1.2. The necessary equipment should be shielded adequatelyto provide accurate readings. The test fixture should beenclosed for worker protection and equipped with an exhaustfan to provide a stable atmosphere. A drive mechanism shouldbe utilized to ensure a uniform rate of feed. The

21、feed rate shallbe proportional to the response time of the metering circuit,that is, it should be run slow enough that maximum readingsare obtained. At no time should this rate of feed exceed 12.2m/min (40 ft/min).X1.3 With 150 mm (6 in.) electrode spacing, the appliedvoltage will be 50 kV. The equi

22、pment shall be designed suchthat at flashover, excessive leakage current will disable thedrive mechanism so that intentional action on the part of theoperator is required to reset the equipment.X1.4 Acceptable values of leakage current shall be a riseabove ambient of less than l1as listed in Table 4

23、.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, ar

24、e entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standa

25、rdsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Commit

26、tee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress

27、 or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ X1.1 Alternative Electrical Test Set-UpFIG. X1.2 Alternative Electrical Test Set-UpF1826 00 (2016)6