ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf

上传人:proposalcash356 文档编号:536241 上传时间:2018-12-06 格式:PDF 页数:11 大小:200.54KB
下载 相关 举报
ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf_第1页
第1页 / 共11页
ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf_第2页
第2页 / 共11页
ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf_第3页
第3页 / 共11页
ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf_第4页
第4页 / 共11页
ASTM F1991-1999(2016) Standard Test Method for Performance of Chinese (Wok) Ranges《中国(锅)靶场性能的标准试验方法》.pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F1991 99 (Reapproved 2016) An American National StandardStandard Test Method forPerformance of Chinese (Wok) Ranges1This standard is issued under the fixed designation F1991; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis

2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andperformance of Chinese ranges. The food service

3、operator canuse this evaluation to select a Chinese range and understand itsenergy performance.1.2 This test method is applicable to nonthermostatically-controlled, gas and electric Chinese ranges, including bothdiscreet burners, elements, and induction units.1.3 The Chinese range can be evaluated w

4、ith respect to thefollowing (where applicable):1.3.1 Energy input rate (10.2),1.3.2 Pilot energy rate, if applicable (10.3), and1.3.3 Heatup energy efficiency and production capacity(10.5).1.4 The values stated in inch-pound units are to be regardedas standard.1.5 This standard does not purport to a

5、ddress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3588 Pract

6、ice for Calculating Heat Value, CompressibilityFactor, and Relative Density of Gaseous Fuels2.2 ANSI Standard:3ANSI Z83.11 American National Standard for Gas FoodService Equipment2.3 ASHRAE Standard:4ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental Data3. Terminology3.1 Definitions

7、:3.1.1 Chinese range, nan appliance that cooks food by adirect or indirect heat transfer, which is powered by a singleheat source comprised of either a gas burner or an electricalelement or induction technology that is independently con-trolled. Used in conjunction with woks.3.1.2 energy input rate,

8、 npeak rate at which Chinese rangeconsumes energy (Btu/h or kW).3.1.3 heatup energy, nenergy consumed by the Chineseranges as it is used to raise the temperature of water in a wokfrom 70 6 2F to 200 6 2F under full input rate.3.1.4 heatup energy effciency, nquantity of energy im-parted to the water,

9、 expressed as a percentage of energyconsumed by the Chinese range during the heatup event.3.1.5 heatup energy rate, naverage rate of energy con-sumption (Btu/h or kW) during the heatup energy efficiencytests.3.1.6 heatup time, ntime required to raise the temperatureof the water from 70 6 2F to 200 6

10、 2F during a heatupenergy efficiency test.3.1.7 pilot energy rate, naverage rate of energy consump-tion (Btu/h) by a Chinese ranges continuous pilot, if appli-cable.3.1.8 production capacity, nmaximum rate (lb/h) at whichthe Chinese range heats water in accordance with the heatupenergy-efficiency te

11、st.3.1.9 testing capacity, nthe capacity (gal) at which thewok is operated during the heatup test, which is at the waterlevel mark.3.1.10 uncertainty, nmeasure of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.1This test method is und

12、er the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Oct. 1, 2016. Published November 2016. Originallyapproved in 1999. Last previous edition approved in 2010 as F1991 99

13、 (2010).DOI: 10.1520/F1991-99R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Nat

14、ional Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co

15、nshohocken, PA 19428-2959. United States13.1.11 water level mark, na level of water, which is even(horizontal) with the top portion of the well or chamber, thatcradles the wok. This will be used to determine the testingcapacity.3.1.12 well/chamber, nthe ring which supports the wokover the heat sourc

16、e.3.1.13 wok, na bowl shaped vessel used to contain thewater that is being heated by the Chinese range.4. Summary of Test Method4.1 The Chinese range is connected to the appropriatemetered energy source, and energy input rate is determined foreach type of cooking well on the Chinese range and for th

17、eentire Chinese range (all cooking wells operating at the sametime) to confirm that the appliance is operating within 5 % ofthe nameplate energy input rate. The pilot energy consumptionalso is determined when applicable to the Chinese range beingtested.4.2 Energy consumption and time are monitored a

18、s eachwell of the Chinese range is used to heat the water in the wokfrom 70 to 200F (21 to 93C) at the full-energy input rate.Heatup energy efficiency and production capacity are calcu-lated from this data.5. Significance and Use5.1 The energy input rate is used to confirm that the Chineserange unde

19、r test is operating at the manufacturers rated input.This test also indicates any problems with the electric powersupply or gas service pressure.5.2 The pilot light, where applicable, energy rate can beused by the food service operator to estimate energy consump-tion during noncooking periods.5.3 He

20、atup energy efficiency is a precise indicator of Chi-nese range energy performance under full-load conditions.Thisinformation enables the food service operator to considerenergy performance when selecting a Chinese range.5.4 Production capacity is used by food service operators tochoose a Chinese ra

21、nge that matches their food output require-ments.6. Apparatus6.1 Analytical Balance Scale, for measuring water and wokweights with a resolution of 0.01 lb and an uncertainty of 0.01lb.6.2 Barometer, for measuring absolute atmosphericpressure, to be used for adjustment of measured gas volume tostanda

22、rd conditions, and it shall have a resolution of 0.2 in. Hgand an uncertainty of 0.2 in. Hg.6.3 Canopy Exhaust Hood, 4 ft in depth, wall-mounted withthe lower edge of the hood 612 ft from the floor and with thecapacity to operate at nominal exhaust ventilation rate of 300cfm per linear foot. This ho

23、od shall extend a minimum of 6 in.past both sides of the cooking appliance and shall not incor-porate side curtains or partitions. Makeup air shall be deliveredthrough face registers or from the space, or both.6.4 Data Acquisition System, for measuring energy andtemperatures, capable of multiple cha

24、nnel displays updating atleast every 2 s.6.5 Gas Meter, for measuring the gas consumption of aChinese range, shall be a positive displacement type with aresolution of at least 0.01 ft3and a maximum uncertainty of nogreater than 1 % of the measured value for any demand greaterthan 2.2 ft3/h. If the m

25、eter is used for measuring the gasconsumed by the pilot lights, it shall have a resolution of atleast 0.01 ft3and a maximum uncertainty no greater than 2 %of the measured value.6.6 Pressure Gage, for monitoring gas pressure. It shallhave a range of zero to 15 in. H2O, a resolution of 0.5 in. H2O,and

26、 a maximum uncertainty of 1 % of the measured value.6.7 Stop Watch, with a 1-s resolution.6.8 Temperature Sensor, for measuring gas temperature inthe range of 50 to 100F with an uncertainty of 61F.6.9 Thermocouple(s), industry standard Type T or Type Kthermocouple wire with a range of 50F to 250F an

27、d anuncertainty of 61F.6.10 Watt-Hour Meter, for measuring the electrical energyconsumption of a Chinese range, shall have a resolution of atleast 10 Wh and a maximum uncertainty no greater than 1.5 %of the measured value for any demand greater than 100 W. Forany demand less than 100 W, the meter sh

28、all have a resolutionof at least 10 Wh and a maximum uncertainty no greater than10 %.7. Reagents and Materials7.1 Water, having a maximum hardness of three grains pergallon. Distilled water may be used.7.2 Wok, due to the varying wok styles, shapes, andmaterials, the testing wok shall be the wok rec

29、ommended bythe manufacturer for the Chinese range to be tested.8. Sampling8.1 Chinese RangeSelect a representative productionmodel for performance testing.9. Preparation of Apparatus9.1 Install the Chinese range according to the manufactur-ers instructions under a 4 ft deep canopy exhaust hoodmounte

30、d against a wall with the lower edge of the hood 612 ftfrom the floor. Position the Chinese range so the front edge is6 in. inside the front edge of the hood. The length of theexhaust hood and active filter area shall extend a minimum of6 in. beyond both sides of the Chinese range. In addition, both

31、sides of the Chinese range shall be 3 ft from any side wall, sidepartition, or other operating appliance. The exhaust hoodventilation rate shall be 300 cfm per linear foot of the hoodlength. The associated heating or cooling system for the spaceshall be capable of maintaining an ambient temperature

32、of 756 5F within the testing environment while the exhaustventilation system is operating.F1991 99 (2016)29.2 Connect the Chinese range to a calibrated energy testmeter. For gas installations, install a pressure regulator down-stream from the meter to maintain a constant pressure of gasfor all tests

33、. Install instrumentation to record both the pressureand temperature of the gas supplied to the Chinese range andthe barometric pressure during each test so that the measuredgas flow can be corrected to standard conditions. For electricinstallations, a voltage regulator may be required during tests

34、ifthe voltage supply is not within 62.5 % of the manufacturersnameplate voltage.9.3 For a gas Chinese range, adjust (during maximumenergy input) the gas supply pressure downstream from theappliances pressure regulator to within 62.5 % of the operat-ing manifold pressure specified by the manufacturer

35、. Makeadjustments to the appliance following the manufacturersrecommendations for optimizing combustion. Proper combus-tion may be verified by measuring air free CO in accordancewith ANSI Z83.11.9.4 For an electric Chinese range, confirm (while theelements are energized) that the supply voltage is w

36、ithin62.5 % of the operating voltage specified by the manufacturer.Record the test voltage for each test.NOTE 1It is the intent of the testing procedure herein to evaluate theperformance of a Chinese range at its rated gas pressure or electricvoltage. If an electric unit is rated dual voltage, that

37、is, designed to operateat either 208 or 240 V with no change in components, the voltage selectedby the manufacturer, or tester, or both, shall be reported. If a Chineserange is designed to operate at two voltages without a change in theresistance of the heating elements, the performance of the unit,

38、 forexample, may differ at the two voltages.10. Procedure10.1 General:NOTE 2Prior to starting these test methods, a tester should read theoperating manual and fully understand the operation of the appliance.10.1.1 For gas Chinese range, record the following for eachtest run:10.1.1.1 Higher heating v

39、alue,10.1.1.2 Standard gas pressure and temperature used tocorrect measured gas volume to standard conditions,10.1.1.3 Measured gas temperature,10.1.1.4 Measured gas pressure,10.1.1.5 Barometric pressure,10.1.1.6 Ambient temperature, and10.1.1.7 Energy input rate during or immediately prior totest.N

40、OTE 3Using a calorimeter or gas chromatograph in accordance withaccepted laboratory procedures is the preferred method for determiningthe higher heating value of gas supplied to the Chinese range under test.It is recommended that all testing be performed with natural gas having ahigher heating value

41、 of 1000 to 1075 Btu/ft3.10.1.2 For a gas Chinese range, add any electric energyconsumption to gas energy for all tests, with the exception ofthe energy input rate test (see 10.2).10.1.3 For an electric Chinese range, record the followingfor each test run:10.1.3.1 Voltage while elements are energize

42、d,10.1.3.2 Ambient temperature, and10.1.3.3 Energy input rate during or immediately prior totest run.10.1.4 For each test run, confirm that the peak input rate iswithin 65 % of the rated nameplate input. If the difference isgreater than 5 %, terminate testing and contact the manufac-turer. The manuf

43、acturer may make appropriate changes oradjustments to the Chinese range.10.2 Energy Input Rate:10.2.1 For a gas Chinese range, operate one of the cookingunits wells with the control(s) in the full “on” position. Allowthe cooking unit to operate for 15 min.10.2.2 At the end of the 15-min stabilizatio

44、n period, beginrecording the energy consumption for the cooking unit for thenext 15 min.10.2.3 If an electrical unit cycles within the 15-min timeperiod required for the test, record only the energy used duringthe noncycling period starting from the instant that the cookingunit has been turned on.10

45、.2.4 For an electric Chinese range, operate one of thecooking units wells with the control(s) in the full “on” positionand record the energy consumption of the cooking unit for thenext 15 min.NOTE 4When confirming the nameplate rated input for an inductionChinese range, the wok must be in the well/c

46、hamber and filled with waterto a level which prevents the wok from boiling dry over the 15-min testperiod. Allowing the wok to boil dry may cause damage to the inductionunit, or the wok, or both.10.2.5 Repeat the procedure in 10.2.1 through 10.2.4 foreach cooking well/chamber on the Chinese range an

47、d recordthe energy consumption for the specified time period, as well asthe position of the cooking well/chamber, for example, left toright, or left front, left rear etc.10.2.6 Repeat the procedure in 10.2.1 through 10.2.4 oper-ating all of the Chinese range cooking wells at the same time,recording

48、the energy consumption of the entire Chinese rangefor the specified time period.10.2.7 In accordance with 11.4, report the measured energyinput rate for separate cooking unit tested and for entireChinese range (all cooking units operating at the same time).Report the nameplate rating for each separa

49、te cooking unittested and for the complete Chinese range when applicable.NOTE 5The nameplate rated input of a Chinese range is specifiedgenerally as the sum of the nameplate ratings of each of the individualcooking units located on the Chinese range. For example, a Chinese rangewith two 80 000-Btu h burners has a nameplate rating of 160 000 Btu h.Due to this fact, the measured input rate of the entire Chinese range top issometimes different from the nameplate rating. The nameplate rating iscompared (see 10.2.6) against the measured rating

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1