ASTM F2009-2000(2011) Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses《测定模块化假体锥形连接的轴向拆解力的标准试验方法》.pdf

上传人:rimleave225 文档编号:536281 上传时间:2018-12-06 格式:PDF 页数:4 大小:152.48KB
下载 相关 举报
ASTM F2009-2000(2011) Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses《测定模块化假体锥形连接的轴向拆解力的标准试验方法》.pdf_第1页
第1页 / 共4页
ASTM F2009-2000(2011) Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses《测定模块化假体锥形连接的轴向拆解力的标准试验方法》.pdf_第2页
第2页 / 共4页
ASTM F2009-2000(2011) Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses《测定模块化假体锥形连接的轴向拆解力的标准试验方法》.pdf_第3页
第3页 / 共4页
ASTM F2009-2000(2011) Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses《测定模块化假体锥形连接的轴向拆解力的标准试验方法》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F2009 00 (Reapproved 2011)Standard Test Method forDetermining the Axial Disassembly Force of TaperConnections of Modular Prostheses1This standard is issued under the fixed designation F2009; the number immediately following the designation indicates the year oforiginal adoption or, in t

2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes a standard methodology fordetermining the force required

3、, under laboratory conditions, todisassemble tapers of implants that are otherwise not intendedto release. Some examples are the femoral components of atotal or partial hip replacement or shoulder in which the headand base component are secured together by a self-lockingtaper.1.2 This test method ha

4、s been developed primarily forevaluation of metal and ceramic head designs on metal tapersbut may have application to other materials and designs.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not pur

5、port to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E4

6、 Practices for Force Verification of Testing MachinesF1636 Specification for Bores and Cones for ModularFemoral Heads33. Summary of Test Method3.1 The axial disassembly test method provides a means tomeasure the axial locking strength of the taper connection formodular prostheses.3.2 Following assem

7、bly, an axial tensile force is applied todisassemble the taper connection and the maximum force isrecorded.4. Significance and Use4.1 This test method helps to assess the axial locking forceof a modular taper. Examples of these devices are described inSpecification F1636. Some types of devices that

8、may utilizethis type of connection are the modular shoulder and modularhip prostheses. Additional means of evaluating the lockingmechanisms of tapers may be appropriate, depending upon thedesign of the device.4.2 This test method may not be appropriate for all implantapplications. The user is cautio

9、ned to consider the appropriate-ness of the practice in view of the materials and design beingtested and their potential application.4.3 While this test method may be used to measure the forcerequired to disengage tapers, any comparison of such data forvarious component designs must take into consid

10、eration thesize of the implant and the type of locking mechanismevaluated.5. Apparatus5.1 The cone portion of the assembly shall be constrainedby suitable fixtures that can sustain high loads.5.2 The fixtures shall be constructed so that the line of loadapplication is aligned with the axes of the ma

11、le and femaletaper components within 61.5.2.1 For example, modular heads may be assembled by asolid metal 100 cone as shown in Fig. 1. The cone shouldprovide line contact around the diameter of the head.5.2.2 For example, modular heads may be disassembledwith a metal cage that surrounds the head and

12、 provides evencontact around the inferior edge of the head as shown in Fig. 2.5.3 The testing machine shall conform to the requirementsof Practices E4. The loads used to determine the attachmentstrength shall be within the range of the testing machine asdefined in Practices E4.5.4 The test machine s

13、hould be capable of delivering acompressive and tensile force at a constant displacement rate.The test machine should have a load monitoring and recordingsystem.6. Sampling and Test Specimens6.1 The male and female taper components can be finishedimplants or they can be simplified test specimens. Th

14、e testspecimens shall have tapers manufactured to the specifications1This test method is under the jurisdiction of ASTM Committee F04 on Medicaland Surgical Materials and Devices and is the direct responsibility of SubcommitteeF04.22 on Arthroplasty.Current edition approved March 1, 2011. Published

15、April 2011. Originallyapproved in 2000. Last previous edition approved in 2005 as F2009 00 (2005).DOI: 10.1520/F2009-00R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re

16、fer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of a finished implant, including material, and preferablymanufactured with the same equipment.6.2 The supporting

17、 material around the female taper shall besimilar in size and shape to the finished implant.6.3 A minimum of five taper assemblies shall be tested todetermine the axial disassembly force between the taperedcomponents. Pairing of the components shall be random unlessotherwise reported. The appropriat

18、eness of performing mul-tiple tests on the same taper connection will depend on thedesign and application of the device.6.4 Sterilization of test components is not required unless ithas known effects on the parts being evaluated. Generally,sterilization does not have an effect on metallic materials.

19、7. Procedure7.1 Following normal laboratory cleaning procedures toremove any debris or other surface contaminants, the tapercomponents are assembled on a suitable test machine. Asuggested procedure for cleaning and drying of the specimensis given in Appendix X1.7.2 Each specimen should be characteri

20、zed prior to testing.This information may include, but is not limited to, thefollowing: material, hardness, bore and taper diameters, con-centricity, surface roughness, taper angle, and length of en-gagement.7.3 Tapers can be assembled using two methods. Dependingon the intended use, the user may us

21、e the assembly method thatbest suits the taper application.7.3.1 Constant Rate Assembly MethodA 2 kN peak staticload is applied to the taper component along the long axis ofthe taper within 6 1; the load may be applied using a constantdisplacement rate until the maximum load (2 kN) is achieved.A sug

22、gested displacement rate is 0.05 mm/s.7.3.2 Drop Weight Assembly MethodThe two componentsmay be assembled with an impact load, that is, a 907-g weightdropped from a 254-mm height.7.4 Disassembly ProcedureThe taper assembly should beplaced in appropriate fixtures in a qualified test machine. Thefixtu

23、re should be capable of maintaining the load axis angle towithin 61. Special care should be taken to ensure that noartificial hoop stresses or bending moments are placed on thetaper assembly while disassembling the tapers. A displacementrate of 0.05 mm/s may be used. The load and displacementshould

24、be recorded continuously until the test is terminated.7.5 Testing of each specimen shall be terminated when thedisassembly load drops by at least 90 % of the peak load.8. Report8.1 The test report shall include the following:8.1.1 The device name, materials, assembly method, loadversus displacement

25、graph, sample size, and manufacturer andlot number, if applicable. Additional information pertaining tothe drop weight method is desirable and may include, but is notlimited to, the following: description of the drop weightapparatus, drop weight mass, drop height.8.1.2 The maximum load required to d

26、isassemble the tapers.8.1.3 The displacement rate if the constant rate method isused.8.1.4 Additional information characterizing each test speci-men prior to testing is desirable to better interpret the testresults. This information may include, but is not limited to theFIG. 1 Modular Head AssemblyF

27、IG. 2 Modular Head DisassemblyF2009 00 (2011)2following: material, hardness, bore and taper diameters, con-centricity, surface roughness, taper angle, and length of en-gagement.9. Precision and Bias9.1 No information can be presented on the precision andbias of this test method for measuring the axi

28、al disassemblyforce of tapers because no material having an acceptedreference value is available.10. Keywords10.1 arthroplasty; disassembly; heads; hip prosthesis;modular; shoulder prosthesis; tapersAPPENDIXES(Nonmandatory Information)X1. METHOD FOR CLEANING SPECIMENSX1.1 Rinse with tap water to rem

29、ove bulk contaminants.X1.2 Wash in an ultrasonic cleaner in a solution of 1 %detergent for 15 min.X1.3 Rinse in a stream of diluted water.X1.4 Rinse in an ultrasonic cleaner of distilled water for 5min.X1.5 Rinse in a stream of distilled water.X1.6 Allow to air dry at room temperature.X2. RATIONALEX

30、2.1 It is not the intent of this method to specificallyaddress the locking mechanisms ability to maintain its integ-rity with sequential assemblies and disassemblies. If deemedappropriate by the user, the method could be considered fordetermining the ability of the locking mechanism to resistdegrada

31、tion after repeated assemblies.X2.2 Modular femoral heads have been used in varioustotal hip replacement (THR) designs since approximately1970. This concept provides features to suit the patient asplanned preoperatively, or selected intraoperatively by thesurgeon such as component material, neck len

32、gth, and headdiameter, or both.X2.3 Modular heads typically are installed in surgery usingmanual impact loads; however, because there can be largevariations due to individual strength, impact rate, hammermass, off-axis loading, soft tissue damping, etc., and becauseimpact and dissociation forces are

33、 directly related4,5a repeat-able assembly method is recommended in order to comparedissociation forces.X2.3.1 Other assembly methods, however, could be desir-able. Two other methods have been discussed: the dropped-weight impact method and manufacturers recommendation.Some manufacturers may provide

34、 a tool that delivers therecommended force to assemble the modular components.These methods could be justified, but because of the potentialvariation in assembly loads and limited access to instruments,these methods are not recommended for this test method. Forthe instances that necessitate these as

35、sembly methods, properdocumentation detailing the procedure should be required.X2.4 An aspect of modular junction integrity to considermay be the effect of fatigue. Fatigue is known to affect themechanical stability of materials and components that fittogether. It may be necessary to determine the p

36、ost fatiguedisengagement force of modular junctions.4Loch, K.A. Gleason, R.F. Kyle, and J.E. Bechtold, “Axial Pull-Off Strength ofDry and Wet Taper Head Connections on a Modular Shoulder Prosthesis,” TransOrthopaedic Research Society, p. 826, 1994.5Blevens, X. Deng, P.A. Torzilli, D. Dines, and R.F.

37、 Warren, “Disassociation ofModular Humeral Head Components: A Biomechanical and Implant RetrievalStudy,” Shoulder and Elbow Surgery, Vol 6, No. 2, p. 113124.F2009 00 (2011)3ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentione

38、din this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and

39、must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of

40、theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C

41、700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).F2009 00 (2011)4