ASTM F875-1994(2003)e1 Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers《办公室复印机大范围浓度和底色评定用测试方法》.pdf

上传人:towelfact221 文档编号:537436 上传时间:2018-12-06 格式:PDF 页数:3 大小:65.54KB
下载 相关 举报
ASTM F875-1994(2003)e1 Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers《办公室复印机大范围浓度和底色评定用测试方法》.pdf_第1页
第1页 / 共3页
ASTM F875-1994(2003)e1 Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers《办公室复印机大范围浓度和底色评定用测试方法》.pdf_第2页
第2页 / 共3页
ASTM F875-1994(2003)e1 Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers《办公室复印机大范围浓度和底色评定用测试方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F 875 94 (Reapproved 2003)e1Standard Test Method forEvaluation of Large Area Density and Background on OfficeCopiers1This standard is issued under the fixed designation F 875; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi

2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAdjunct references were editorially corrected in April 2006.1. Scope1.1 This test method covers the descr

3、iption and method ofuse for a density and background test target for office copierimage evaluation.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and healt

4、h practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 8.2. Referenced Documents2.1 ASTM Standards:2E 1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus (Filter) ColorimetryF 335 Terminology Rela

5、ting to Electrostatic ImagingF 360 Practice for Image Evaluation of Electrostatic Busi-ness Copies2.2 ASTM Adjunct:Density Target Test Sheets32.3 ANSI Standards:PH 2.17 Density measurementsGeometric conditions forreflection density4PH 2.18 Density measurementsSpectral conditions43. Terminology3.1 De

6、finitionsFor definitions of terms used in this testmethod, refer to Terminology F 335.4. Summary of Test Method4.1 The standard test target is used to evaluate copy densityand background. The method of image evaluation using thistest target is given.5. Significance and Use5.1 The copy image quality

7、is affected by many factors;including the copier, supplies, and environmental conditions.The density and background image quality is particularlysignificant relative to aesthetic appearance, the visual impres-sion of blackness, and the ability to distinguish informationfrom background.5.2 The test t

8、arget may also be used to evaluate the copier orsupplies.6. Apparatus6.1 Reflection Densitometer, meeting the requirements ofANSI PH 1.17 and PH 1.18, capable of measuring the smallestsolid circle (of the test target) which has a diameter of 6 mm.6.2 Reflectometer, meeting the requirements of Test M

9、ethodE 1347.7. Materials7.1 Test Target, for the evaluation of density and back-ground image quality. It shall have the same configuration andlayout as shown in Fig. 1.38. Precautions8.1 This test target can be used to measure density andbackground for different copier conditions (machine adjust-men

10、t, machine configuration, supplies, environment, etc.).Careful notation of these conditions should be made so thatcomparison tests can be made.8.2 The color and type of copy paper used will affect thedensity and background measurements.8.3 The method of fixing (fusing) of the image on the copymay af

11、fect the degree of gloss and may affect the differencebetween the perceived density and measured reflective density.1This test method is under the jurisdiction ofASTM Committee F05 on BusinessCopy Products and is the direct responsibility of Subcommittee F05.04 onElectrostatic Copy Products.Current

12、edition approved March 15, 1994. Published May 1994. Originallypublished as F 875 84. Last previous edition F 875 84 (1988).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, r

13、efer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJF0875. Original adjunct produced in 1994.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM Inte

14、rnational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.9. Procedure9.1 Using the test target in 7.1, establish a procedure(Practice F 360) for producing copies in a controlled manner.Evaluate the copy system at the site of its proposed installationunder the li

15、ne voltage conditions which normally apply. Read,understand, and follow the manufacturers instructions onoperation of the copier.9.1.1 Load supplies into the copier. Follow manufacturersdirections for adjustments of various controls.9.1.2 Turn on the copier.9.1.3 Set exposure control, if one is prov

16、ided, to either endof the exposure range.9.1.4 Using test target, make a copy. Note exposure setting,if copier has an exposure control, and date on copy, as well asinformation concerning temperature and relative humidity.9.1.5 Vary exposure control, if one is provided, and makecopies at various sett

17、ings. Note setting, date, temperature andrelative humidity on each copy. If an exposure control isprovided, it must always be varied from the same direction.9.1.6 Visually determine optimum setting of any controls,that is the one yielding the best copy, in your opinion.9.1.7 At the optimum setting,

18、make the number of copiesthat would constitute a normal length of run. This will allowcomparison of copy uniformity. The test target should beplaced or fed into the copier in the same orientation each timeand the optimum exposure setting must be set from the samedirection on the exposure control dev

19、ice, should one beavailable.9.1.8 At the optimum setting, reverse the orientation of thetest original placed or fed into the copier and make a copy. Thiscan then be compared to previous copies to determine possibleoriginal orientation variations.10. Interpretation of Results10.1 Reflection Density M

20、easurements:10.1.1 CalibrationDensitometer shall be calibrated bymanufacturers procedures.10.1.2 Density MeasurementsAminimum of three densitymeasurements shall be made on the imaged copies of the testtarget. The smallest circle in each of three arrays shall bemeasured and an average value shall be

21、used. The measure-ment should be made at the center of each circle and anyobvious imperfections avoided. Additional measurements onthe larger circles may be used and equivalent circles averaged.Higher density in the larger circles indicates better solid areafill-in.NOTE 1Densitometers are available

22、in a variety of apertures. Theideal aperture is approximately one half the diameter of the smallest circle.If the instrument is equipped with a smaller aperture, a sufficient numberof readings must be taken to ensure a valid value.10.2 Background Percent Reflectance Measurements:10.2.1 CalibrationRe

23、flectometer shall be calibrated bymanufacturers procedures.10.2.2 Background reflectance measurements shall be ob-tained by measuring the reflectance in each of the threeenclosed white circular areas on the imaged copy of the testtarget. The average of at least three values shall be used. Ifsignific

24、ant variation in the values is noted, the number ofmeasurements should be increased.10.2.3 The background reflectance change due to the copiercan be determined by calculating the difference between thevalue obtained in 10.2.2 and the average of the three valuesobtained using blank copy paper. The pr

25、ocess may affect thesurface characteristics of the paper and therefore the reflec-tance reading.10.2.4 Comparison of background reflectance is difficultwhen different copy papers are used since the untoned paperreflectance may vary. A comparison may be made if thereflectance value for each paper det

26、ermined from the back-ground areas is subtracted from the reflectance value obtainedfor each paper before the copy is made. This calculated valuefor each paper can be used to compare the overall backgroundwhen different papers are used. A higher calculated reflectancedifference indicates higher over

27、all background.10.2.5 This measurement is useful to determine the overalluniform background and can not be used to determine isolatedlocalized particles in the nonprinted areas.10.3 Higher reflectivity indicates lower background andcleaner copy.11. Precision and Bias511.1 Precision:11.1.1 Repeatabil

28、ityTwo test results obtained by the sameoperator and test apparatus under essentially the same condi-tions may be expected 95 % of the time to agree with eachother to within 3 % of the average of the test results.11.1.2 ReproducibilityTwo test results obtained in differ-ent laboratories for the same

29、 sample of material may beexpected 95 % of the time within 6 % of the average of the twotest samples.5Supporting data are available at ASTM Headquarters. Request RR: F051001.FIG. 1 Configuration and Layout of Test TargetF 875 94 (2003)e1211.2 BiasThere is no acceptable reference material suit-able f

30、or determining the bias, therefore bias cannot be deter-mined.12. Keywords12.1 copier background; copier image density; imagequalityASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard

31、 are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif n

32、ot revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which

33、 you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F 875 94 (2003)e13