1、Designation: F967 03 (Reapproved 2018)Standard Practice forSecurity Engineering Symbols1This standard is issued under the fixed designation F967; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number i

2、n parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice utilizes symbols to depict security systemsand equipment requirements for architectural or engineeringdrawings that are produced

3、either manually or by computeraided design (CAD). The symbols depicted include somesymbols that have already been somewhat universally acceptedor that have already been adopted by a standards-writing body,such as by the National Fire Protection Association.1.2 It is not proposed that all of the symb

4、ols need to beutilized since the level of detail required for drawings is likelyto vary. Generic symbols of a class of security device may besufficient in some instances. Moreover, the need to provide ameasure of security in the actual drawing may also suggest aneed to utilize a generic symbol rathe

5、r than to depict the exactdevice being installed.1.3 In the event that a greater level of detail is required, it ispossible to combine many of the symbols to create newsymbols that achieve the desired level. While some combina-tions of symbols are shown, it would be impractical to attemptto depict e

6、very conceivable combination of symbols. It is alsothe intent of this practice that the symbols be capable of beingcontinuously expanded and modified as the industry state of theart changes or as emphasis varies. For example, little attentionis given to document security in the security symbols sinc

7、esuch requirements are not generally fully met during construc-tion periods but are rather developed and provided for subse-quently. Since much of this equipment is not installed but is“placed,” such as furniture, there is only one symbol proposed(for example, for document shredders).1.4 This standa

8、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This inter

9、national standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) C

10、ommittee.2. Keywords2.1 computer aided design; security engineering; symbols1. ANNOTATIONExisting EquipmentPoint and Zone IndicatorConnection Between Devices (for example,button and lock)Detail and Reference DrawingDoor Number (if more than one door in room,use sub-letter)Room or Space NumberDevice

11、Number (reference device schedule)Device ReferenceA = Drawing SheetB = DetailC = Device Zone Number2. ACCESS CONTROLGeneric Card Reader (reference door schedule orspecifications for type): P = pedestal mount1This practice is under the jurisdiction of ASTM Committee F12 on SecuritySystems and Equipme

12、ntand is the direct responsibility of Subcommittee F12.10 onSystems Products and Services.Current edition approved Sept. 1, 2018. Published October 2018. Originallyapproved in 1986. Last previous edition approved in 2011 as F967 03 (2011).DOI: 10.1520/F0967-03R18.Copyright ASTM International, 100 Ba

13、rr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom

14、mendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Card Reader with Touch PadToken-Type Access ControlCCTV and Card ReaderCCTV and IntercomSplit Lens CCTV with ID Card ReceptacleApartment Type CCTV with House Phone andTouch Pad (insert “K” “”, as appropria

15、te for key switch)Biometric Access Control Device (reference doorschedule or specifications for type)Touch Pad Lock or Device, Mechanical orElectronic (reference door schedule for type)Turnstile (reference door schedule for type andfunction)Post and Rail (rope)Generic Screening DeviceX: M = Metal De

16、tectorE = Explosive DetectorX = X-rayT = Tag Detector (EAS)Sally PortIndicating Interlocking DoorsIndicating Space is a “Man-Trap”Card Access ReaderB = BarcodeW = WiegandP = ProximityM = Mag StripeF = Elevator Floor CallH = Elevator Hall CallT = TokenS = Smart CardBiometrics Access Control DeviceH =

17、 Hand GeometryF = Finger PrintV = VoiceR = Eye RetinaI = Eye IrisKeypad DeviceCard Reader with KeypadCard Reader with Time and Attendance3. ANNUNCIATION: CONSOLE/PANELStrip (Tallyroll) PrinterPrinterTime Clock with Card ReaderCentral Processing UnitCRT (cathode ray tube/display)Static Map Display (f

18、or dynamic map display,use CRT symbol)KeyboardJeweled Signal LightPanel Light Indicator (R = Red, A = Amber, W= White, V = Violet, G = Green, Y = Yellow,B = Blue, O = Orange)Multiplex PanelPanel Sound IndicatorPanel Sound and Light IndicatorResetF967 03 (2018)2Push-Button, Momentary/Make (circuitclo

19、sing)Time Delay ModuleControl Device Module, Door ReleaseEnd-of-Line Device ModuleResistance (Ohms) (indicate value; that is,10 000 )ThousandsDry Contacts, SetContacts with CurrentPower SwitchField PanelT: C = Card ReaderA = AlarmControl PanelT: B = BurglarF = FireP = PerimeterD = DoorCentral Proces

20、sing UnitKeyboardPrinterPower SupplyT: L = LockC = CameraP = PanelI = Intercom4. ANNUNCIATION: DEVICESAnnunciation Device, GenericBuzzerGeneric BellGeneric ChimeGeneric Security Horn (differentiate from firehorn; use also for local alarm)Audio DeviceT: L = LockC = CameraI = Intercom5. BARRIERS AND V

21、EHICLE CONTROLSGeneric Fence (reference type in specification orschedule)X: (Fence Type)Y: (Sensor Type, see below)Generic Masonry (reference type in specificationor schedule)X: C = Chain Link; W = Welded Mesh;B = Barbed Top; R = Razor RibbonY: E = Electrostatic; T = Taut Wire;V = VibrationDitch Bar

22、rierDitch and Berm BarrierRoll-Up GateSliding GateSwing GateTraffic ArmTraffic Lights (use “M” for miniature)Generic Vehicle Sensor (reference specificationor schedule for type)F967 03 (2018)3Tire TreddleSecurity Grill with Emergency ReleaseSecurity GrillGeneric Security ScreenRepair/Secure Window O

23、perator (use “R” forrepair,“ S” for security)TurnstileRevolving DoorTraffic ArmVehicle Loop DetectorSecurity Window ScreenT: S = ShadeB = Blind (see Section 10 for alarm screen)6. COMMUNICATIONSTelephone HandsetIntercom, Master, Hands-Free (use “S” for slaveor sub)Intercom, Push-to-TalkGeneric Speak

24、er (reference specification orschedule for type)Nurse Station, Master, Wall Mount (use “D” fordesk mount)Nurse Call System Device, GenericPaging System Device, GenericPrivate Telephone System Device, GenericPublic Telephone System Device, GenericTwo-Way Radio Base StationFlush Mount Panel Board/Cabi

25、netSurface Mount Panel Board/CabinetIntercomT: M = MasterS = SubstationTwo-Way Radio MicrophoneCellular TransmitterTelephone DialerT: D = Digital CommunicatorV = Voice DialerFiber Optic ModuleT: Tx = TransmitterR = ReceiverT = Transceiver7. ELECTRICALResistorEnd-of-Line DeviceAmplifierAntennaF967 03

26、 (2018)4Antenna, LoopBatteryStand-By BatteryCapacitorCircuit BreakerGroundCircuit Return, CommonCircuit Return, FrameRelay, Normally OpenRelay, Normally ClosedRelayTransformerTransformer (on floor plan)RectifierDiodeVisual Signaling DeviceFuseMotorGeneratorJunction Box, in CeilingJunction Box, WallE

27、lectrical Outlet, Wall, DuplexTriplex ReceptacleIntersection, No ConnectionIntersection, ConnectionConduit Run, Exposed, Turn Down (rigidsteel1 in.)Conduit Run, Exposed, ArmoredConduit Run, Concealed, Turn Up (EMT)Conduit Run, Exposed, Turn Up (PVC)BoosterShielded CableCoaxial CableConductor, Twiste

28、d PairConductor, Security System (4 conductors, No.18 AWG)Fiber Optic CableLocal Radio Signal LinkLong Range Radio Signal LinkPower PanelHome Run, 2 Conductors, 18 AWG (number ofarrows indicates number of circuits)FeederF967 03 (2018)5ManholeRotary SwitchToggle Switch, SPSTToggle Switch, SPDTNonlock

29、ing, Momentary CircuitClosing (make)Nonlocking, Momentary CircuitOpening (break)TransferLocking, Circuit Closing (make)Locking, Circuit Opening (break)Form A, SPST, N.O.Form B, SPST, N.C.Form C, SPDTSPST (Single-Pole, Single-Throw)SPDT (Single-Pole, Double-Throw)DPST (Double-Pole, Single-Throw)DPDT

30、(Double-Pole, Double-Throw)8. LIGHTINGIncandescent Light Fixture, Flush, CeilingMountIncandescent Light Fixture, Flush, Wall MountIncandescent Light Fixture, Surface,Ceiling MountIncandescent Light Fixture, Surface,Wall MountFluorescent Fixture, Ceiling MountDedicated Security Lighting, Low Pressure

31、 So-dium (use other designators for other types,that is, MV = mercury vapor)Minimum Foot-Candles or Lamberts this AreaSpotlight/FloodlightOutdoor Strobe LightIlluminate this AreaInfrared IlluminatorStreet Light, Pole-Mounted9. MISCELLANEOUSSecurity Container; Safe; File CabinetDocument DestroyerSafe

32、, Tack-Welded to Structural MemberSignageBar/Grill/Seal this LocationTimerGun Port10. SENSORSGeneric Volumetric Motion Sensor (Mono)X: M = MicrowaveI = Passive IRU = UltrasonicD = Dual TechGeneric Volumetric Beam Sensor (Bi-Static)X: M = MicrowaveI = InfraredP = Photo-cellF967 03 (2018)6Generic Glas

33、s Breakage SensorT: A = AudioS = ShockCapacitance SensorTemperature SensorPad/Mat SwitchBullet-Resistant Polycarbonate Glazing withAlarmed Conductive LayerWater SensorWater Motion SensorGeneric Buried SensorX: S = SeismicL = Leaky CoaxM = MagneticStrain SensorVibration/Shock Sensor (nonfence type)So

34、nic Sensor (audible, doppler shift)Sound Discriminator (responds to frequencies)(see also glass break sensor)Listen-in Audio SensorRadarSonarSeismic Sensor (local stimuli, point type)Strong Motion Seismic Sensor (earthquake)Bank Vault Sensor or Sensor ArrayElectronic Tag SensorLocal Control Unit for

35、 SensorsExplosive Dye-Pack AntennaBreak-Dowell GridIndicates “Lace this Partition”Motion DetectorT: M = MicrowaveIR = InfraredU = UltrasonicX = Request-for-ExitD = Dual TechnologyBi-Static Beam SensorT: M = MicrowaveI = InfraredF: TX = TransmitRX = ReceiveSecurity Screen with AlarmT: S = ShadeB = Bl

36、indScreening DeviceT: M = Metal DetectorE = Explosives DetectorX = X-RayT = Tag Detector (EAS)A = Access11. CCTVGeneric CameraX: P = Pan; A = Auto-Pan;PT = Pan Tilt; C = ConcealedY: F = Fixed; Z = Zoom; S = SplitRefer to camera schedule and specification for: Type (CCD, film, intensified)Size(13 in.

37、;12 in.) Enclosure (environmental, explosion proof,“scoop”) Mount (wall, ceiling, pole) Lens (type, size) Pan Pre-Sets Associated Alarm Switching Signal TransmissionReference Monitor/Switching Schedule orSpecifications for Size, Type, MountingPan ControlZoom ControlPan-Zoom-Tilt ControlF967 03 (2018

38、)7Video Tape RecorderVideo Disc RecorderAny Control Unit, GenericAuto Control Unit, GenericVideo Motion DetectorScreen Splitter (Video Multiplexer)Microprocessor Based SwitcherX = Number of InputsY = Number of OutputsDistribution AmplifierGround Loop CorrectorVideo Switcher Control KeyboardCCTV Swit

39、cher, Passive, ManualCCTV Switcher, Homing SequentialCCTV Switcher, Looping Input, Homing Se-quentialCCTV Switcher, Bridging Output, SequentialCCTV Switcher, Looping Input, Bridging Se-quentialCCTV Switcher, Auto Alarm Homing Sequen-tialCCTV Switcher, RemoteMATV AntennaMonitorT: V = VideoD = DataG =

40、 GraphicM = MultiscreenCameraT: S = Scoop WedgeC = CornerD = DomeB = BoardE = EnvironmentalCamera with Pan/Tilt/ZoomT: D = DomeE = EnvironmentalVideo Control KeyboardVideo MultiplexerVideo Motion DetectorRecorderT: V = VideoA = AudioD = Digital12. SWITCHESGeneric SwitchX: D = DoorS = Spring Loaded/D

41、eadmanR = Roll-Up Overhead DoorG = GateW = Window Sliding DoorF = FootrailT = TamperH = HingeP = Plunger RollerL = Level Tilt MercuryB = Bill Cash Drawer(Reference door schedule or specification forgap, size, mounting, balanced, tampered, EOLresistor)Generic Key SwitchX: S = ShuntW = Watch-Tour Stat

42、ionD = Door ReleaseR = ResetF967 03 (2018)8Keypad SwitchAutomatic Monitoring SwitchT: T = TempB = Bal. MagH = HumidityW = WaterL = LatchG = GateManually Operated SwitchT: E = EmergencyL = LockF = FootM = MatH = HoldupPush ButtonT: P = PanicD = DuressX = Request-for-ExitR = Door ReleaseB = Bell PushR

43、elay SwitchT: F = Fire Alarm13. DOOR AND LOCKING HARDWARESliding DoorLock (see specification for type)Roll-Up DoorSecurity Curtain, Sliding/RollingSecurity Curtain, RollDownVault DoorVault Door with Day DoorBullet-Resistant ConstructionDoor with Vision PanelInterlock IndicationDoor View Lens ViewerH

44、atch DoorMultiPoint Locking DoorBarricade BarElectromagnetic LockX: D = Door SwitchElectrified Lock SetX: F = Fail-SafeS = Fail-SecureReplace/Install Hinge (use “R” for repair, “I”for install)Pin Hinge Pin or Replace with Security HingeElectric HingeConcealed HingeHinge Switch, Bullet-Nose TypeElect

45、ric StrikeX: F = Fail-SafeS = Fail-SecureElectric Bolt/LatchX: F = Fail-SafeS = Fail-SecureSecurity Fastener, GenericHasp AssyPadlockMechanical Keypad Door LockReplace/Install Door (use “R” for repair, “I” forinstall)Replace/Install Frame (use “R” for repair, “I”for install)Replace/Install Door Clos

46、er (use “R” for repair,“I” for install)F967 03 (2018)9Replace/Install Center MullionEscutcheonAstragalReplace/Install Security Cylinder (use “R” forrepair, “I” for install)Key LockSecure TransomDoor OperatorAutomatic Opener Actuation PadAutomatic Opener, Microwave TypePanic HardwareVertical Bolts in

47、 Header and FloorDoor Lock, Mortised (use “R” for rimlock)With Local AlarmWith Cylinder Lock, Blank One SideWith Remote AlarmWith Local and Remote AlarmWith Cylinder Lock and Lever or Thumb Leveron One SideDirection of Always OpenDirection of Always LockedKey-In-Knob, Both SidesDeadbolting LocksetPo

48、sitive Latching LocksetPositive Latching and Locking LocksetCombination Deadbolting and Positive Latchingwith Dual Action Thumb Lever One Side andCylinder on OtherDeadboltDeadlatchCam LockF967 03 (2018)10Electronic LockT: M = MagneticS = StrikeL = Latch SetH = HybridD = DeadboltExit DeviceT: E = Ele

49、ctrifiedM = MechanicalD = Delayed EgressX = High SecurityPower Transfer HingeT: 2 = Two-Wire4 = Four-Wire, etc.ANNEX(Mandatory Information)A1. SAMPLE COMBINATION DEVICESVideo IntercomCamera with Card ReaderCamera with KeypadVideo Intercom MasterT: RWith Door ReleaseF967 03 (2018)11APPENDIX(Nonmandatory Information)X1. COMMENTARYX1.1 This commentary provides a brief history and ratio-nale for a significant revision to this practice. This revisionexpanded the focus and intent of this standard beyond apractice for manual drafting to encompass co