ASTM F2187-2002(2011) Standard Test Method for Determining the Effect of Random Frequency Vibration on a Membrane Switch or Membrane Switch Assembly《测定隔膜开关或隔膜开关组配随机频率振动影响的标准试验方法》.pdf

上传人:赵齐羽 文档编号:537993 上传时间:2018-12-07 格式:PDF 页数:2 大小:51.29KB
下载 相关 举报
ASTM F2187-2002(2011) Standard Test Method for Determining the Effect of Random Frequency Vibration on a Membrane Switch or Membrane Switch Assembly《测定隔膜开关或隔膜开关组配随机频率振动影响的标准试验方法》.pdf_第1页
第1页 / 共2页
ASTM F2187-2002(2011) Standard Test Method for Determining the Effect of Random Frequency Vibration on a Membrane Switch or Membrane Switch Assembly《测定隔膜开关或隔膜开关组配随机频率振动影响的标准试验方法》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F2187 02 (Reapproved 2011)Standard Test Method forDetermining the Effect of Random Frequency Vibration on aMembrane Switch or Membrane Switch Assembly1This standard is issued under the fixed designation F2187; the number immediately following the designation indicates the year oforigina

2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes procedures for determiningthe effect

3、of random vibration, within the specified frequencyrange, on switch contacts, mounting hardware, adhered com-ponent parts, solder or heat stakes, tactile devices, and cable orribbon interconnects associated with a membrane switch ormembrane switch assembly.1.2 The values stated in SI units are to be

4、 regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and de

5、termine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 contact closurethe event at which a specified resis-tance is achieved on a membrane switch.2.1.2 membrane switcha momentary switching device inwhich at least one contact is on, or made of, a flexibl

6、esubstrate.2.1.3 specified resistancemaximum allowable circuit re-sistance as measured between two test points whose internalcontacts, when held closed, complete a circuit.2.1.4 test pointstwo pre-selected conductive points in acircuit loop, possibly including a switch.3. Significance and Use3.1 Vib

7、ration encountered in the field is usually random innature and this test can be used to determine the effects ofrandom excitation on the membrane switch.3.2 Random vibration can cause mechanical fatigue andfailure by switch components either loosening or otherwisechanging over time.3.3 Experience ha

8、s shown that this test will expose potentialfailures associated with the electronic components of a mem-brane switch, where tests of lower levels will not.3.4 This practice can be used to qualify a membrane switchfor aerospace, medical and other applications.3.5 This test is potentially destructive,

9、 intended for devicequalification.4. Apparatus4.1 Vibration Fixture, capable of holding the unit under testand subjecting it to the specified random frequency andduration as described in the In-Process Test.4.2 Contact Closure Detection Device, instrumentation ca-pable of resolving a switch opening

10、time of greater than orequal to 1.0 ms.5. Procedure5.1 Pre-Test Setup:5.1.1 Secure membrane switch on vibration test surfacewith appropriate fixturing.5.1.2 Function testing to be specified and performed againafter test completion for comparison.5.1.3 Connect switch detection leads to test points on

11、 themembrane switch.5.2 In-Process Test:5.2.1 Subject to a random vibration over the bandwidth of10 to 2000 for a duration of 1 h per each orthogonal axis (totalof 3 h). The break points shall be as follows:NOTE 1The tolerance shall be 63db for this test.Frequency G2/Hz40 0.042000 0.04Overall GRMS 8

12、.855.2.2 Visual inspection shall be conducted after each axis ofvibration.5.2.3 Electrical and functional testing shall be specified bythe qualified engineer and performed at either test completionor between each axis of vibration.5.2.4 A failure shall occur if parts show signs of mechanicalfatigue,

13、 cracking, excessive rubbing or loosening of the sup-porting hardware. Afailure should also be designated if contact1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved Feb

14、. 1, 2011. Published March 2011. Originallyapproved in 2002. Last previous edition approved in 2002 as F2187 - 02. DOI:10.1520/F2187-02R11.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.closure occurs during vibration and or electri

15、cal or otherfunctional testing provides unsatisfactory results.6. Report6.1 Report the following information:6.1.1 Description of vibration equipment used,6.1.2 Description of mounting fixture including drawing,diagrams, and photos as necessary,6.1.3 Functional testing results before and after test,

16、6.1.4 Description of the visual fatigue of any components orhardware,6.1.5 Contact closure event; when occurred and axis beingtested,6.1.6 Temperature,6.1.7 Relative humidity,6.1.8 Barometric pressure,6.1.9 Part number or description of switch, or both, and6.1.10 Date of test.7. Keywords7.1 contact

17、closure; frequency; membrane switch; vibrationASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, a

18、nd the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revis

19、ion of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you s

20、houldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).F2187 02 (2011)2