ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf

上传人:bowdiet140 文档编号:538020 上传时间:2018-12-07 格式:PDF 页数:3 大小:38.26KB
下载 相关 举报
ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F 2199 02Standard Test Method forDetermining Dimensional Stability of Resilient Floor Tileafter Exposure to Heat1This standard is issued under the fixed designation F 2199; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio

2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the changein linear dimensions of resilient floor tile af

3、ter exposure to heat.1.2 The values stated in inch-pound units shall be regardedas the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p

4、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 177 Practice for Use of the Terms Precision and Bias inASTM Test Methods2E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2F 14

5、1 Terminology Relating to Resilient Floor Coverings3F 536 Test Method for Size of Resilient Floor Tile by DialGage Method3F 2055 Test Method for Size and Squareness of ResilientFloor Tile by Dial Gage Method33. Terminology3.1 Definitions are in accordance with Terminology F 141unless otherwise indic

6、ated.4. Significance and Use4.1 The final appearance of an installed tile floor dependsupon several factors. These include but are not limited to sizeand squareness of the tile, the quality of joint cut, the qualityand preparation of the subfloor and the skill of the installer.Long term appearance o

7、f the installed floor is also dependenton but not limited to the ability of the tile to resist shrinkagedue to internal stress relief. This test method is used to measurethe ability of floor tile to retain its original dimensionsfollowing exposure to heat simulating a long service life atreasonable

8、and expected temperatures.5. Apparatus5.1 Mechanical Convection-Type Oven, or equivalent, ca-pable of maintaining a temperature of 180 6 3.6F (82 6 2C),with inside dimensions large enough to hold several tileshorizontally on aluminum exposure plates.5.2 Specimen Exposure Plates, consisting of flat 1

9、4gage,0.0625in. (1.6mm), thick aluminum. The aluminum expo-sure plates may be contained in a rack, either fixed in orremovable from the rack, and should be at least 1 in. (25.4 mm)larger in each linear dimension than the linear dimension of thespecimen tested. If contained in a rack, the spacing bet

10、weeneach plate should be at least 0.625in. (16mm). The rack shallbe constructed with all four sides open.5.3 Block and Dial Gage Assembly, as described in TestMethod F 536 or F 2055.5.4 Forced Air Cooling (Fan, Blower, etc.), may be used foraccelerating specimen conditioning before heating and after

11、cooling exposure to ensure proper equilibrium of test specimen(see 6.1 and 7.1).6. Test Specimen6.1 The test specimen consists of a resilient floor tile.Typical floor tile dimensions are 9 by 9 in. (229 by 229 mm) or12 by 12 in. (305 by 305 mm). Other sizes in square orrectangular dimensions may als

12、o be tested.7. Conditioning7.1 A conditioned room maintained at a temperature of 73.46 1.8F (23 6 1C) and 50 6 5 % relative humidity.8. Procedure8.1 Reference PlatesDifferent tile sizes, with respectivereference plates, can be specified if the size and squarenessapparatus is designed to handle the t

13、esting and measurement ofalternate sizes.8.2 Conditioning Before ExposureCondition the speci-mens at 73.4 6 1.8F (23 6 1C) and 50 6 5 % relativehumidity for not less than 24 h prior to starting the test unlessotherwise specified.1This test method is under the jurisdiction of ASTM Committee F06 on Re

14、silientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethodsPerformance.Current edition approved Aug. 10, 2002. Published October 2002.2Annual Book of ASTM Standards, Vol 14.02.3Annual Book of ASTM Standards, Vol 15.04.1Copyright ASTM International, 100 Barr Harbor D

15、rive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.3 Conditions for MeasurementMeasure the tile speci-men (6.1) in the conditioning room (7.1).8.4 Calibration of Block and Dial Gage IndicatorsCalibrate the block and dial gage indicators as indicated in TestMethod F 536 or F 2055.8.

16、5 Initial MeasurementPlace the tile specimen, afterconditioning (8.2), on the block and dial gage assembly (5.3)face up and measure in the machine direction (MD), ifidentifiable, and the across machine direction (AMD), ifidentifiable, according to the procedure in Test Method F 536or F 2055. These p

17、oints shall be marked as a reference on thetile so that the final measurements will be made at the sameexact locations. Measure the tile according to Test MethodF 536 or F 2055 and eliminating the squareness measurementstep.8.6 ExposurePlace the tile specimen face up in theexposure rack (5.2) on the

18、 aluminum exposure plates. Positionthe plates on racks in the heated cabinet (5.1) at 180 6 3.6F(82 6 2C) for 6 6 0.25 h. Expose the four open sides of therack to the direction of the airflow within the cabinet so that thecirculating air passes freely over the tile specimens.8.7 Conditioning after E

19、xposureRemove the tile/plateassembly from the oven cabinet (5.1). Allow the assembly tocondition at room temperature (7.1) for at least 24 h. Weargloves when handling the hot aluminum plate.8.8 Final MeasurementsDetermine the dimensional sta-bility by measuring the separation of reference points bef

20、oreand after the heat exposure for both MD and AMD. Removethe tile from the aluminum plate after re-conditioning andre-measure on the block and dial gage assembly (5.3) accord-ing to 8.5. Make the measurements at the same reference pointsas the initial measurements.NOTE 1Squareness measurements are

21、not to be taken or recordedsince they are not directly considered in the dimensional stabilitydetermination.9. Calculations9.1 The final MD average measurements are subtractedfrom initial MD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Anegative value

22、 indicates shrinkage, and a positive value indi-cates expansion.9.2 The final AMD average measurements are subtractedfrom initial AMD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Anegative value indicates shrinkage, and a positive value indi-cates exp

23、ansion.9.3 The MD and AMD dimensional stability results arecalculated, recorded, and reported as individual measurementson an applicable characteristic chart or report form. Thecalculated linear dimensional change may also be representedas a percentage change as follows:Linear Change % 5FDf2 Di!DiG3

24、 100 (1)where:Df= the average final length, andDi= the average initial length.10. Precautions10.1 While no supporting data exist, it is important that thealuminum exposure plates for supporting the specimen be keptsmooth and polished so that surface friction does not interferewith free shrinkage or

25、growth of the specimens. The platesmust be flat and free of convex or concave warp.10.2 For any type of block and dial gage, care must be takenso that the tile is properly seated against the base horizontalindex guide when a specific measurement is being taken. Tilewith concave or convex edges can e

26、asily be read incorrectly.10.3 The zero setting of the multiple dial indicators shouldbe checked prior to, during use (if a large quantity of specimensare to be tested), and at the conclusion of the test (see 8.4).10.4 All foreign matter or loose particles must be removedfrom the edges of the tile a

27、nd from the angle between the blockbase and the horizontal index guide prior to making measure-ments. A simple brush-off by hand of each edge is usuallysufficient.10.5 Each dial gage foot must be flat, no rounded or wornsurfaces.10.6 When making measurements, care must be taken so asnot to apply und

28、ue pressure and distort the tile.10.7 Check horizontal index guide for abrasive wear.10.8 The three reference points for measurement (MD andAMD) shall be marked on the face of the tile and measuredwith the face-up on the block and dial gage assembly to ensurethat any embossing along the edge of the

29、tile wear surface willnot affect the measurements.10.9 Check that the tile specimen is placed face-up on thealuminum exposure plate.10.10 Make sure that the dial gage foot is at the samereference points for both the initial and final measurements.The tile must be held flat. A domed or curled tile co

30、uld beconfused with dimensional change.10.11 Prior to specimen exposure, it is important that theoven cabinet (5.1) be checked to be certain that it is controllingat 180 6 3.6F (82 6 2C).10.12 After exposure, do not remove the tile from thealuminum plate until the reconditioning time elapses (see 6.

31、1).11. Precision and Bias411.1 The precision was determined by inter-laboratoryround robin testing according to Practices E 177 and E 691 andis listed in 11.2 for machine direction measurements and in11.3 for across machine direction measurements.11.2 Precision Statement for Machine Direction Dimen-

32、sional Stability:11.2.1 Requirements for Determining Precision of TestMethod: AnalysisThe number of laboratories, materials, anddeterminations in this study does meet the minimum require-ments for determining precision prescribed in Practice E 691:4A research report is available from ASTM Internatio

33、nal Headquarters. RequestRR:F06-1007.F2199022ThisStudyASTM E 691MinimumLaboratories 6 6Materials 5 4Determinations 12 211.2.2 Precision Statement for Test Method: AnalysisPrecision, characterized by repeatability, Sr, r, and reproduc-ibility, SR, R has been determined for the materials to be:Materia

34、ls Average Sr SR r RMaterial A -0.0034583 0.0052579 0.0052579 0.0147220 0.0147220Material B -0.0051181 0.0041771 0.0057826 0.0116958 0.0161913Material C 0.0015764 0.0020731 0.0026663 0.0058046 0.0074657Material D -0.0023333 0.0029237 0.0384626 0.0081863 0.1076954Material E -0.0040972 0.0029009 0.003

35、3733 0.0081226 0.009445211.3 Precision Statement for Across Machine DirectionDimensional Stability:11.3.1 Requirements for Determining Precision of TestMethod: AnalysisThe number of laboratories, materials, anddeterminations in this study does meet the minimum require-ments for determining precision

36、 prescribed in Practice E 691:ThisStudyASTM E 691MinimumLaboratories 6 6Materials 5 4Determinations 12 211.3.2 Precision Statement for Test Method: AnalysisPrecision, characterized by repeatability, Sr, r, and reproduc-ibility, SR, R has been determined for the materials to be:Materials Average Sr S

37、R r RMaterial A 0.004979 0.003809 0.003970 0.010665 0.011116Material B -0.003299 0.005647 0.007118 0.015811 0.019931Material C 0.003000 0.002077 0.002271 0.005817 0.006360Material D -0.002049 0.01907 0.034792 0.053396 0.097418Material E -0.005146 0.002418 0.003577 0.006771 0.010017average = the nume

38、rical average of test results for allreplicates from all laboratories,Sr = the within-laboratory standard deviation of theaverage, andR = 2.83SR.11.4 Repeatability (Sr, r)In comparing two average valuesfor the same material obtained by the same operator using thesame equipment on the same day, the m

39、eans should be judgednot equivalent if they differ by more than the r value for thatmaterial and condition.11.5 Reproducibility (SR, R)In comparing two averagevalues for the same material obtained by different operatorsusing different equipment on different days, the means shouldbe judged not equiva

40、lent if they differ by more than the R valuefor that material and condition. (This applies between differentlaboratories or between different equipment within the samelaboratory).11.6 The previous judgments will have an approximate 0.95(95 %) probability of being correct. Other materials would beexp

41、ected to give somewhat different results. For further infor-mation on the methodology used in this section or for furtherclarification please refer to Practice E 691.11.7 BiasNo information can be presented on the bias ofthe test method procedure because material having an acceptedreference value is

42、 unavailable.12. Keywords12.1 dimensional stability; resilient flooring; tileASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validi

43、ty of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your commen

44、ts are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have no

45、t received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F2199023

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1