ASTM F2252 F2252M-2013e1 Standard Practice for Evaluating Ink or Coating Adhesion to Flexible Packaging Materials Using Tape《使用胶带评估柔性包装材料与油墨和涂层粘合性的标准实施规程》.pdf

上传人:inwarn120 文档编号:538213 上传时间:2018-12-07 格式:PDF 页数:2 大小:52.42KB
下载 相关 举报
ASTM F2252 F2252M-2013e1 Standard Practice for Evaluating Ink or Coating Adhesion to Flexible Packaging Materials Using Tape《使用胶带评估柔性包装材料与油墨和涂层粘合性的标准实施规程》.pdf_第1页
第1页 / 共2页
ASTM F2252 F2252M-2013e1 Standard Practice for Evaluating Ink or Coating Adhesion to Flexible Packaging Materials Using Tape《使用胶带评估柔性包装材料与油墨和涂层粘合性的标准实施规程》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F2252/F2252M 131Standard Practice forEvaluating Ink or Coating Adhesion to Flexible PackagingMaterials Using Tape1This standard is issued under the fixed designation F2252/F2252M; the number immediately following the designation indicates the yearof original adoption or, in the case of

2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEDesignation was corrected editorially in October 2013.1. Scope1.1 This practice describes a means of ev

3、aluating ink orcoating adhesion to flexible packaging materials. This practiceis intended for use on flexible packaging materials whosesurfaces are not damaged by the application and removal oftape.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.

4、 The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.2. Referenced Documents2.1 ASTM Standards:2D3330/D3330M Test Method for PeelAdhesion of P

5、ressure-Sensitive TapeE171 Practice for Conditioning and Testing Flexible BarrierPackaging3. Significance and Use3.1 Poor adhesion of ink or coating to the base substrate canimpact the readability of printed materials, affect the function-ality of coated materials, or create a source of contaminatio

6、n.This practice provides a means for evaluating the adhesion ofink or coating to a flexible packaging material.3.2 For purposes of resolving inter-laboratorydisagreements, test methods developed from this practice maybe improved by defining and controlling the pressure andmethod of tape application,

7、 (for example, using weightedroller), and the speed and angle of tape removal.3.3 This practice does not address acceptability criteria.These need to be jointly determined by the user and producerof the product.4. Apparatus4.1 3M #610 or Sellotape office adhesive tape is commonlyused for this proced

8、ure, typically 19 to 25 mm (34 to 1 in.)wide. Whichever tape is chosen should be agreed upon bycustomer and supplier.4.1.1 Manufacturers storage and shelf-life recommenda-tions should be followed or acceptability determined throughreal-time aging and laboratory tests. Test Method D3330/D3330M gives

9、guidance on testing. Again, as stated in 3.3,acceptability criteria is a matter of agreement between cus-tomer and supplier.5. Sampling5.1 The number of samples tested should be adequate to bepredictive of performance. Caution should be taken wheneliminating samples with defects as this can bias res

10、ults.6. Conditioning6.1 Conditioning of the samples will depend on the materialunder evaluation. If conditioning before testing is appropriate,normal, and desirable, refer to E171 for guidance.6.2 Before testing catalyzed or cured inks or coatings, orboth, ensure that the samples have been exposed t

11、o theappropriate conditions for sufficient time to allow completecure.7. Procedure7.1 Lay sample to be tested on a flat surface. Sample shouldlay flat and smooth without wrinkles, creases, or folds.7.2 Cut a piece of tape long enough to cover the printed orcoated area of interest on the sample. For

12、large areas it may beeasier to work with several shorter pieces of tape. Handlingapplication and removal of tape is simpler when length of tapedoes not exceed 12 in.1This practice is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcomm

13、ittee F02.20 onPhysical Properties.Current edition approved May 1, 2013. Published June 2013. Originallyapproved in 2003. Last previous edition approved in 2008 as F2252 03 (2008).DOI: 10.1520/F2252-13E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S

14、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.3 Apply tape to sample using a smooth ev

15、en motionwithout wrinkling tape or sample. Run thumb or forefingeralong tape to make sure it is fully adhered, without any bubblesin surface.7.4 Hold sample flat to surface with one hand, use otherhand to peel back tape at an angle of approximately 120 to150. Lift tape, pulling back with an even, mo

16、derate motion.Typically 305 to 460 mm (12 to 18 in.) per second.NOTE 1Varying the amount of time after tape is applied may affect theresults.7.5 Examine the test sample for missing print or coatinggaps.7.6 Examine tape for any ink or coating removed from thetest sample. As an aid for visual inspecti

17、on reference standardsmay be created and used to determine degree of transfer.7.7 Record results. Characterize the degree of adhesionusing mutually agreed upon references. If multiple colors ofink are present, results may vary by color and may be reportedthat way. This is a subjective test and opera

18、tor training iscrucial for consistent reporting of test results.8. Keywords8.1 adhesion; anchorage; coating; ink; print; tape testASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard a

19、re expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not

20、 revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which y

21、ou may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,Unite

22、d States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).F2252/F2252M 1312

展开阅读全文
相关资源
猜你喜欢
  • ASTM F1794-1997(2016)e1 Standard Specification for Hand-Operated Globe-Style Valves for Gas (Except Oxygen Gas) and Hydraulic Systems《气体 (氧气除外) 和液压系统用手动球型阀的标准规格》.pdf ASTM F1794-1997(2016)e1 Standard Specification for Hand-Operated Globe-Style Valves for Gas (Except Oxygen Gas) and Hydraulic Systems《气体 (氧气除外) 和液压系统用手动球型阀的标准规格》.pdf
  • ASTM F1795-2000(2006) Standard Specification for Pressure-Reducing Valves for Air or Nitrogen Systems《空气或氮气系统用减压阀标准规范》.pdf ASTM F1795-2000(2006) Standard Specification for Pressure-Reducing Valves for Air or Nitrogen Systems《空气或氮气系统用减压阀标准规范》.pdf
  • ASTM F1795-2000(2013) Standard Specification for Pressure-Reducing Valves for Air or Nitrogen Systems《空气或氮气系统用减压阀的标准规格》.pdf ASTM F1795-2000(2013) Standard Specification for Pressure-Reducing Valves for Air or Nitrogen Systems《空气或氮气系统用减压阀的标准规格》.pdf
  • ASTM F1796-1997(2002) Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压探测器用标准规范 第1部分 超过600伏交流电压用电容式探测器.pdf ASTM F1796-1997(2002) Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压探测器用标准规范 第1部分 超过600伏交流电压用电容式探测器.pdf
  • ASTM F1796-2009 Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《第1部分 超过600伏交流电压用电容式探测器的标准规范》.pdf ASTM F1796-2009 Standard Specification for High Voltage Detectors&8212 Part 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《第1部分 超过600伏交流电压用电容式探测器的标准规范》.pdf
  • ASTM F1796-2009(2014) Standard Specification for High Voltage DetectorsPart 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压检测器的标准规格 第1部分 超过600 V交流电压用电容式》.pdf ASTM F1796-2009(2014) Standard Specification for High Voltage DetectorsPart 1 Capacitive Type to be Used for Voltages Exceeding 600 Volts AC《高压检测器的标准规格 第1部分 超过600 V交流电压用电容式》.pdf
  • ASTM F1797-1998(2003) Standard Test Method for Acoustic Emission Testing of Insulated Digger Derricks《绝缘采掘式起重机声音发射试验的标准试验方法》.pdf ASTM F1797-1998(2003) Standard Test Method for Acoustic Emission Testing of Insulated Digger Derricks《绝缘采掘式起重机声音发射试验的标准试验方法》.pdf
  • ASTM F1797-2009 Standard Test Method for Acoustic Emission Testing of Insulated and Non-Insulated Digger Derricks.pdf ASTM F1797-2009 Standard Test Method for Acoustic Emission Testing of Insulated and Non-Insulated Digger Derricks.pdf
  • ASTM F1797-2009e1 Standard Test Method for Acoustic Emission Testing of Insulated and Non-Insulated Digger Derricks《绝缘采掘式起重机声音发射试验的标准试验方法》.pdf ASTM F1797-2009e1 Standard Test Method for Acoustic Emission Testing of Insulated and Non-Insulated Digger Derricks《绝缘采掘式起重机声音发射试验的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1