ASTM F2359-2004(2011) Standard Test Method for Determining Color of a Membrane Switch Backlit with Diffuse Light Source《测定散射光源薄膜开关的背光颜色的标准试验方法》.pdf

上传人:eveningprove235 文档编号:538494 上传时间:2018-12-07 格式:PDF 页数:2 大小:52.26KB
下载 相关 举报
ASTM F2359-2004(2011) Standard Test Method for Determining Color of a Membrane Switch Backlit with Diffuse Light Source《测定散射光源薄膜开关的背光颜色的标准试验方法》.pdf_第1页
第1页 / 共2页
ASTM F2359-2004(2011) Standard Test Method for Determining Color of a Membrane Switch Backlit with Diffuse Light Source《测定散射光源薄膜开关的背光颜色的标准试验方法》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F2359 04 (Reapproved 2011)Standard Test Method forDetermining Color of a Membrane Switch Backlit withDiffuse Light Source1This standard is issued under the fixed designation F2359; the number immediately following the designation indicates the year oforiginal adoption or, in the case of

2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determining theluminous color of a backlit membrane swit

3、ch. As written, itapplies to a fully assembled switch. For specific purposes, itcan be applied to partially assembled switches, with theunderstanding that the results pertain only to the partialassembly and will be modified as the further assembly pro-ceeds.1.2 The values stated in SI units are to b

4、e regarded asstandard. No other units of measurement are included in thisstandard.2. Terminology2.1 Definitions:2.1.1 graphic overlaya graphically illustrated layer, oftenattached to the top side of the switch assembly for protection,cosmetic purposes, or to indicate the location and function ofthe

5、switch keys.2.1.2 illumination layera layer in the construction of amembrane switch, which may or may not be a physicallydistinct layer which contains or supports the source of illumi-nation for the switch. Examples are a flexible layer containinglight emitting diodes (LEDs), often either the top or

6、 bottomlayer of the switch, or a flexible layer of electroluminescent(EL) material, often a distinct and separate layer added atassembly.2.1.3 membrane switcha momentary switching device, inwhich at least one contact is on, or made of, a flexiblesubstrate.2.1.4 UUTunit under test.3. Significance and

7、 Use3.1 Illumination of a switch or of certain features of a switchoften has a functional purpose and must meet specification tosatisfy the functional requirements of the switch.3.2 Illumination of the switch can be affected by variationsin the quality and design of the overlay and its application.3

8、.3 This test method addresses only the optical and visualappearance of the switch and not its electrical function.3.4 This test method is non-destructive.3.5 If this test method is applied to the entire switchassembly, the results can be applied to the whole device.However, it may be sufficient and

9、practical to apply the testeither to a subassembly only, or to the illumination only, inwhich case the results apply to that layer only and the net effecton the fully assembled device must be extrapolated.4. Interferences4.1 Tests on incomplete assemblies give results appropri-ately to that state of

10、 assembly. Specifically, later application ofa graphic overlay may alter the results.4.2 Failure to fill the sampling aperture of the colorimeterwill bias the results in a way which is not necessarilypredictable and for which compensation cannot be made.4.3 Since every light source changes character

11、istics as itages, it must be recognized that the results apply to a particularinterval in the lifetime of the system. Characterization of theaging properties may be addressed in a separate test method.4.4 PerpendicularitySince the angular distribution ofemitted light can be altered by any material t

12、hrough which itpasses, it is important that photometer be held perpendicular tothe area to be sampled.4.5 TemperatureSince the performance of many lightsources can vary with temperature, it is important to allow theUUT to thermally stabilize, if necessary, and then record theambient temperature at w

13、hich the measurements are made.4.6 Ambient LightStray light sources will be detected bythe photometer and will affect UUT color measurement. It isimportant to measure the ambient light before illuminating theUUT. This ambient light reading should be zero or as close tozero as possible.1This test met

14、hod is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved July 1, 2011. Published August 2011. Originallyapproved in 2004. Last previous edition approved in 2004 as F2359-04. DOI:10.1520/F235

15、9-04R11.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Apparatus5.1 A working or mounting surface to hold and support theUUT assembly, providing electrical access to the terminationregion from which the illumination is to be powe

16、red and visibleaccess to the regions at which the luminous color is to bemeasured.5.2 A power supply providing appropriate and adequatepower to drive the illumination device(s) with appropriateconnector(s). This should be specified as dc or ac, with voltageand power level given, and ideally should b

17、e switched.5.3 A calibrated device to measure the color of the lumi-nance. This is typically a spot colorimeter or similar equip-ment, with a fairly compact sampling aperture (1-cm diameterat the minimum working distance). Output should be in one ofthe CIE Tristimulus descriptions, such as the 1931

18、values (x, y)or the 1976 values (u, v).25.4 A means to support the color measuring instrument at afixed distance and orientation to the UUT.5.5 A means to control stray light and prevent it fromentering the aperture of the photometer.6. Procedure6.1 Mount UUT on the working surface with the luminous

19、surface visible.6.2 Attach a switched power source as appropriate to theluminous device set to the design operating point.6.3 Mount the colorimeter so that the axis of its field of viewis perpendicular to the area of the UUT to be measured. Ensurethat the sampling aperture is filled by the area to b

20、e measuredon the UUT.6.4 Measure the stray light level by taking a colorimeterreading while the UUT luminous source is not powered. If thisstep yields a significant measurement, do not proceed, but takesteps to reduce the stray light present. Unlike luminance orradiance (integrated spectrum) measure

21、ments, color measure-ments may not easily be compensated for the effects of straylight.6.5 Switch on the luminous source in the UUT assembly.6.6 Measure the color values of the UUT.7. Report7.1 Report the following information:7.1.1 State of UUT (assembled or not),7.1.2 Stray light level,7.1.3 Color

22、 coordinates,7.1.4 Power conditions for the luminous device,7.1.5 Location and size of the sample area or areas,7.1.6 Colorimeter used, sample settings, calibration status,and the size of the sampling aperture,7.1.7 Ambient temperature, and7.1.8 Date of test.8. Keywords8.1 backlit; CIE; color coordi

23、nates; colorimeter; diffuselight; electroluminescent material; light emitting diodes; lumi-nance; luminous color; membrane switch; photometer; radiom-eter; video photometerASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned

24、in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and m

25、ust be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of t

26、heresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C7

27、00, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).2For example, CIE Publication No.15.2, Colorimetry 2d ed., Central Bureau ofCIE, Vienna, 1986.F2359 04 (2011)2

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1