1、Designation: F2409 10 (Reapproved 2016)Standard Guide forFences for Non-Residential Outdoor Swimming Pools, HotTubs, and Spas1This standard is issued under the fixed designation F2409; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision

2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides recommended minimum require-ments for various types of fences for non-residential ou

3、tdoorswimming pools, hot tubs and spas.1.2 The various types of fences may be chain link, wood,vinyl, ornamental steel or aluminum, welded wire, expandedmetal, composite or others that would be incorporated into adesign necessary to support the structure considering its height,application, location,

4、 and climatic condition. All types offences shall be in accordance with ASTM standards.1.3 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be used indepe

5、ndently of the other.Combining values from the two systems may result in non-conformance with the standard. The SI values stated inparentheses are provided for information purposes only.2. Referenced Documents2.1 ASTM Standards:2A392 Specification for Zinc-Coated Steel Chain-Link FenceFabricA491 Spe

6、cification for Aluminum-Coated Steel Chain-LinkFence FabricF552 Terminology Relating to Chain Link FencingF567 Practice for Installation of Chain-Link FenceF668 Specification for Polyvinyl Chloride (PVC), Polyolefinand Other Polymer-Coated Steel Chain Link Fence FabricF900 Specification for Industri

7、al and Commercial SteelSwing GatesF964 Specification for Rigid Poly (Vinyl Chloride) (PVC)Exterior Profiles Used for Fencing and RailingF1043 Specification for Strength and Protective Coatings onSteel Industrial Fence FrameworkF1083 Specification for Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized)

8、Welded, for Fence StructuresF1345 Specification for Zinc-5 % Aluminum-MischmetalAlloy-Coated Steel Chain-Link Fence FabricF2630 Guide for Self-Closing/Self-Latching General-Purpose Gates3. Terminology3.1 See Terminology F552 for definitions of terms relatingto chain link fencing.3.2 Definitions of T

9、erms Specific to This Standard:3.2.1 fence, na type of barrier, which surrounds andobstructs access to the pool, tub or spa.3.2.2 grade, nthe finished elevation at any specified pointof the ground or pavement outside the pool area.3.2.3 hot tub, nsee definition of spa.3.2.4 outdoor, adjlocated outsi

10、de of a completely en-closed building or other structure.3.2.5 non-residential, adjnot situated on the premises of adetached one- or two-family dwelling nor a one-family townhouse less than four stories in height.3.2.6 spa (non-portable), na permanent structure contain-ing water over 24 in. (610 mm)

11、 deep, in which the water-heating and water-circulating equipment are not an integralpart of the product, intended for recreational bathing.3.2.7 spa (portable), na non-permanent structure contain-ing water over 24 in. (610 mm) deep, in which all controls,water-heating, and water-circulating equipme

12、nt are an integralpart of the product, intended for recreational bathing.3.2.8 swimming pool, nan in-ground, on-ground or above-ground structure of a permanent, semi-permanent or portablefabrication containing any depth or shape of water bodydesigned and constructed in accordance with local codes, u

13、sedfor bathing, swimming, racing or other aquatic activities.3.2.9 waters, nany designed natural or man-made area(that is, reservoir, empondment).1This guide is under the jurisdiction of ASTM Committee F14 on Fences and isthe direct responsibility of Subcommittee F14.10 on Specific Applications.Curr

14、ent edition approved July 1, 2016. Published August 2016. Originallyapproved in 2010. Las previous edition approved asF240910. DOI: 10.1520/F2409-10R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSta

15、ndards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Summary of Guide4.1 This guide is based in part upon recommendations of theUnited States Con

16、sumer Product Safety Commission, theNational Center for Injury Prevention and Control, the Ameri-can Medical Association, the American Academy of Pediatrics,and the National Aquatic Coalition, among others.5. Significance and Use5.1 This guide sets forth minimum standard requirementsfor use in local

17、 codes and ordinances relating to non-residentialoutdoor swimming pools, hot tubs, spas, and waters. This guidedoes not have the effect of law, nor is it intended to supersedelocal codes and ordinances of a more restrictive nature.6. Requirements6.1 HeightThe top of the fence to be used around anon-

18、residential outdoor swimming pool, hot tub, spa, or otherwater facility shall be of a height ranging from 48 in. (1.22 m)to 120 in. (3.05 m). The owner or its agents shall select theheight after assessing the potential of intrusion when the poolis closed, taking into consideration the environment lo

19、cation,that is, city, suburban, exurban, or rural; the numbers ofpotential intruders with a likelihood of abilities to scale orpenetrate the fence; will the pool be guarded or patrolled, easeof visibility into the pool area, will the pool area have nightsecurity lighting and will there be an access

20、control securitysystem. For example, a hotel pool that is well lighted andmonitored twenty four hours a day will most likely require a48-in. (1.22-m) high fence, whereas a pool back from a road,not easily visible, not lighted or patrolled, and having no accesscontrol security system will most likely

21、 require the higher120-in. (3.05-m) fence.6.2 VisibilityThe fence shall be so designed and con-structed that it has openness, which allows visibility fromoutside the pool area for patrols, guards, and others to insidethe pool area to identify intruders and trespassers.6.3 Ground ClearanceThe maximum

22、 vertical clearancebetween grade and the bottom of the fence shall be 2 in. (50mm) measured on the side of the fence, which faces away fromthe swimming pool.6.4 Horizontal And Vertical MembersWhere the fence iscomposed of horizontal and vertical members the horizontalmembers shall not extend more th

23、an 0.375 in. (10 mm) outsideof the enclosure. The spacing between vertical members shallbe no greater than 4 in. (102 mm) for fences having twoconsecutive horizontal rails spaced at least 45 in. (1143 mm)apart, measured from the top of one rail to the top of the nextrail. The spacing between vertica

24、l members shall not exceed 134 in. (44 mm) for fence designs having no two consecutivehorizontal members spaced at least 45 in. (1143 mm).6.5 Chain Link FencesMesh opening for chain link fencesshall be 114 in. (32 mm) in compliance with chain link fabricSpecifications A392, A491, F668, and F1345.6.6

25、 Diagonal Members:6.6.1 Where the fence is composed of diagonal members,such as in a lattice fence, any opening created by the diagonalmembers shall be a maximum of 134 in. (44 mm) measured inits largest direction.6.6.2 Diagonal bracing members extending from one cornerto the opposite corner creatin

26、g a ladder effect on all styles offences and gates are not permitted where spacing between thevertical members in any area between posts exceeds 134 in. (44mm).6.7 Structural DesignThe fences shall be structurallydesigned so as to withstand stresses from wind load, ice load orother such environmenta

27、l stresses applicable to the geographicregion in which the fence is installed. The structural design ofthe fence shall comply with local regulations regarding heightor visibility restrictions. Chain link, welded wire and expandedmetal fence framework shall be constructed using frameworkmaterial cite

28、d in Specification F1043, Table 3 Heavy IndustrialFence Framework or Specification F1083. Vinyl fences shall beconstructed of profiles manufactured in accordance with Speci-fication F964.6.8 Access Gates:6.8.1 Double leaf access gates shall be equipped with a dropbar and padlock that is always locke

29、d when the gate is not inuse. Chain link fence double gates shall be in compliance withSpecification F900 and shall be of the height of the fence.6.8.2 Single leaf pedestrian gates shall open outward awayfrom the pool shall be self-closing and shall have a self-latching device in accordance with Spe

30、cification F2630. Therelease mechanism of the latching device shall be located aminimum of 54 in. (1372 mm) above grade. Gates shall belocked when pool area is closed. Chain link fence single gatesshall be in compliance with Specification F900 and shall be ofthe height of the fence or include a tran

31、som above.6.9 The fence shall completely surround the pool structurewhenever possible.6.10 Above ground non-residential pools or on-ground non-residential pools shall be enclosed by the same types offence/barrier as in-ground non-residential pools and meet thecriteria excluding fencing on the perime

32、ter of the above groundpool structure.6.11 Pool IlluminationThe pool, if open for evening ornight use and those complexes unattended during the night thatare illuminated, should be illuminated of evenly distributedintensity to comply with federal, state and local codes. It isrecommended that the gui

33、delines published by the IlluminatingEngineering Society of NorthAmerica be used to determine theappropriable illumination level for each site design. If compe-tition as well as recreational swimming and other wateractivities are to be included in the venue, at least 75-ft candlesshall be provided.

34、Light fixtures in danger of being vandalizedshould have protective coverings.6.12 GroundingWhen applicable the fence shall begrounded in compliance with the requirements of local utilitiesand electrical codes.F2409 10 (2016)27. Prohibited Locations7.1 Swimming pool fence/barriers shall be located so

35、 as toprohibit the use of permanent structures, equipment or similarobjects to aid in climbing the fence/barrier.7.2 Clear ZoneThere shall be an external clear zone of atleast 72 in. (1829 mm) between the swimming pool fence/barrier and any permanent structures or pool equipment such aspumps, filter

36、s, heaters, etc. which can be used as an aid toclimb the fence/barrier. Landscape elements that can support a25-lb (11.34-kg) load or more that can be used as an aid inclimbing shall not be allowed in this clear zone.8. Maintenance and Inspection8.1 It is the responsibility of the owner, occupant or

37、 tenantto maintain the integrity of the fence and to regularly inspectthe gates, doors, etc. for proper closing and latching operation.8.1.1 Safety signs and boards are used to communicateimportant information to users regarding the existence ofhazards and ways to avoid personal injury. The communic

38、ationof safety critical information is a non-delegable responsibilityof owners and operators and often can only be accomplishedthrough the use of appropriately designed informational signs,signboards and placards. Warnings are used:8.1.1.1 To tell people about a threat to their well-beingposed by da

39、ngerous conditions or products;8.1.1.2 To change behavior so that people act safely asopposed to acting unsafely; and8.1.1.3 To remind people of 8.1.1.1 and 8.1.1.2.If it is foreseeable that people will be injured when they actin a certain way, and careful evaluation shows when physicalsafety measur

40、es cannot be provided to ameliorate the conse-quences of their acts then WARNING SIGNS are required onthe fencing around the pool that meet ASTM and ANSIstandards.8.2 Keep the external area near the fence free of toys,furniture or other objects, which could be moved and used toclimb the fence.9. Key

41、words9.1 fence ; fences; barriers; hot tubs; pools; spas; swimmingpoolsASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of

42、any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are

43、 invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not rece

44、ived a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) o

45、f this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 10 (2016)3