ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf

上传人:unhappyhay135 文档编号:539284 上传时间:2018-12-07 格式:PDF 页数:7 大小:88.37KB
下载 相关 举报
ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf_第1页
第1页 / 共7页
ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf_第2页
第2页 / 共7页
ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf_第3页
第3页 / 共7页
ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf_第4页
第4页 / 共7页
ASTM F2696-2014 Standard Practice for Inspection of Aircraft Electrical Wiring Systems《检验航空器电气布线系统的标准实施规程》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F2696 14Standard Practice forInspection of Aircraft Electrical Wiring Systems1This standard is issued under the fixed designation F2696; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb

2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers basic inspection procedures forelectrical wiring interconnect systems for aircraft electricalwiring systems.1.2 This p

3、ractice is not intended to replace any instructionsfor continued airworthiness published by the aircraft or acces-sory manufacturer or type design holder.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units t

4、hat are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the

5、applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 Military Standard:2MIL-C-85049 Connector Accessories, Electrical, GeneralSpecification for2.2 FAA Guidance Material:3FAA Advisory Circular 33.4-3 Instructions for ContinuedAirworthiness; Aircraft Engine High Intensity R

6、adiatedFields (HIRF) and Lightning Protection Features2.3 SAE Documents:4SAE ARP1870 Aerospace Systems Electrical Bonding andGrounding for Electromagnetic Compatibility and SafetySAE Aerospace ARP5583 Guide to Certification of Aircraftin a High Intensity Radiated Field (Hirf) Environment3. Terminolo

7、gy3.1 Acronyms:3.1.1 EWISelectrical wiring interconnection system3.1.2 HIRFhigh-intensity radiated fields3.1.3 ICAinstructions for continued airworthiness3.1.4 LRUline-replaceable unit3.1.5 MSmilitary standard3.1.6 MTBFmean time between failures3.1.7 PTFEpolytetrafluoroethylene3.1.8 RFradio frequenc

8、y3.1.9 STCsupplemental type certificate (Federal AviationAdministration)4. Significance and Use4.1 The term “electrical system” as used in this practicemeans those parts of the aircraft that generate, distribute, anduse electrical energy, including their support and attachments.4.2 The satisfactory

9、performance of an aircraft is dependentupon the continued reliability of the electrical system.4.3 Damaged wiring or equipment in an aircraft, regardlessof how minor it may appear to be, cannot be tolerated. It is,therefore, important that maintenance be accomplished usingthe best techniques and pra

10、ctices to minimize the possibility offailure.4.4 When inspecting and evaluating EWIS, improperwiring, routing, or repairs shall be corrected regardless of theorigin of the error.4.5 This practice is not intended to supersede or replace anygovernment specification or specific manufacturers instructio

11、nregarding electrical system inspection and repair5. Causes of Wire Degradation5.1 The following are considered the principal causes ofwiring degradation and should be used to help focus mainte-nance programs:5.1.1 VibrationHigh-vibration areas tend to acceleratedegradation over time resulting in “c

12、hattering” contacts andintermittent symptoms. High vibration of tie-wraps or stringties can cause damage to insulation. In addition, high vibrationwill exacerbate any existing wire insulation cracking.1This practice is under the jurisdiction of ASTM Committee F39 on AircraftSystems and is the direct

13、 responsibility of Subcommittee F39.02 on Inspection,Maintenance, and Repair.Current edition approved May 1, 2014. Published June 2014. Originallyapproved in 2008. Last previous edition approved in 2008 as F2696 08. DOI:10.1520/F2696-14.2Available from the U.S. Government Printing Office, Superinten

14、dent ofDocuments, Stop: SSOP, Washington, DC 20402-0001.3Available from Federal Aviation Administration (FAA), 800 IndependenceAve., SW, Washington, DC 20591, http:/www.faa.gov.4Available from Society of Automotive Engineers (SAE), 400 CommonwealthDr., Warrendale, PA 15096-0001, http:/www.sae.org.Co

15、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.1.2 MoistureHigh-moisture areas generally acceleratecorrosion of terminals, pins, sockets, and conductors. Note thatwiring installed in clean, dry areas with moderate temperaturesappears

16、 to hold up well.5.1.3 MaintenanceScheduled and unscheduled mainte-nance activities, if done improperly, may contribute to long-term problems and degradation of wiring. Metal shavings anddebris have been discovered on wire bundles aftermaintenance, repair, or alteration work has been performed.Extra

17、 attention shall be given to EWIS inspections aroundareas of previous aircraft maintenance, repair, or alterations.5.1.4 RepairSince wire splices are more susceptible todegradation, arcing, and overheating, extra care shall be givenwhen inspecting repaired wiring.5.1.5 AlterationsAlterations introdu

18、ce another area forenhanced scrutiny for similar reasons as repairs. In addition, analteration may not be documented in the aircraft Instructionsfor Continued Airworthiness and therefore need independentinspection and a concern for proper wiring, attachments,mounting, and wiring routing.5.1.6 Indire

19、ct DamageEvents such as pneumatic ductruptures or duct clamp leakage can cause damage that, whilenot initially evident, can later cause wiring problems. Whenevents such as these occur, surrounding EWIS shall be care-fully inspected to ensure that there is no damage or potentialfor damage evident. In

20、direct damage caused by these types ofevents may be broken clamps or ties, broken wire insulation, oreven broken conductor strands. In some cases, the pressure ofthe duct rupture may cause wire separation from the connectoror terminal strip.6. Procedure6.1 Inspection and Operation ChecksInspect equi

21、pment,electrical assemblies, and wiring installations for damage,general condition, and proper functioning to ensure the con-tinued satisfactory operation of the electrical system. Adjust,repair, overhaul, and test electrical equipment and systems inaccordance with the recommendations and procedures

22、 in theaircraft or component manufacturers maintenance instructionsor both. Replace components of the electrical system that aredamaged or defective with identical parts, aircraft manufactur-ers approved equipment, or its equivalent to the original inoperating characteristics, mechanical strength, a

23、nd environ-mental specifications. A list of suggested problems to look forand checks to be performed are:6.1.1 Damaged, discolored, or overheated equipment,connections, wiring, and installations;6.1.2 Excessive heat or discoloration at high-current-carrying connections;6.1.3 Misalignment of electric

24、ally driven equipment;6.1.4 Poor electrical bonding (broken, disconnected, orcorroded bonding strap) and grounding, including evidence ofcorrosion;6.1.5 Dirty equipment and connections;6.1.6 Improper, broken, inadequately supported wiring andconduit, loose connections of terminals, and loose ferrule

25、s;6.1.7 Poor mechanical or cold solder joints;6.1.8 Condition of circuit breaker and fuses;6.1.9 Insufficient clearance between exposed current-carrying parts and ground or poor insulation of exposedterminals;6.1.10 Broken or missing safety wire, broken bundle lacing,cotter pins, and so forth;6.1.11

26、 Operational check of electrically operated equipmentsuch as motors, inverters, generators, batteries, lights, protec-tive devices, and so forth;6.1.12 Condition of electric lamps; and6.1.13 Missing safety shields on exposed high-voltage ter-minals (that is, 115/200 V ac).6.2 Functional Check of Sta

27、ndby or EmergencyEquipmentAn aircraft should have functional tests performedat regular intervals as prescribed by the manufacturer.6.3 Bus BarsAnnually check bus bars for generalcondition, cleanliness, and security of all attachments andterminals. Grease, corrosion, or dirt on any electrical junctio

28、nmay cause the connections to overheat and eventually fail. Busbars that exhibit corrosion, even in limited amounts, shall bedisassembled, cleaned and brightened, and reinstalled.6.4 Generating SystemInspect generator(s)/alternator(s)for general condition, cleanliness, and security of attachmentand

29、terminals. Any sign of overheating terminals or wiring isreason for rejection. Inspect drive belts for condition and wear.Replace any belt showing signs of abnormal wear or overheat-ing. Inspect brushes for proper condition and wear patterns.Inspect brush holders for condition and signs of arcing or

30、overheating. Inspect voltage regulation components and wiringfor condition and security. Inspect generator(s)/alternator(s)warning system for condition and operation.6.5 Battery InspectionBattery inspection procedures varywith the types of chemical technology and physical construc-tion. Always follo

31、w the battery manufacturers approved pro-cedures. Battery performance at any time in a given applicationwill depend upon the batterys age, state of health, state ofcharge, and mechanical integrity.6.5.1 Aircraft Battery Inspection:6.5.1.1 Inspect battery sump jar (if installed) and lines forconditio

32、n and security.6.5.1.2 Inspect battery terminals and quick-disconnect plugsand pins for evidence of corrosion, pitting, arcing, and burns.Clean as required. Inspect battery cables for condition andsigns of chafing.6.5.1.3 Inspect battery drain and vent lines for restriction,deterioration, and securi

33、ty. Battery drain areas shall be checkedfor signs of structure corrosion.6.5.1.4 Routine preflight and postflight inspection proce-dures shall include observation for evidence of physicaldamage, loose connections, and electrolyte loss.6.5.1.5 Perform capacity performance test of battery permanufactu

34、rers instructions to ensure continued airworthiness.6.5.1.6 Inspect battery warning system components (if in-stalled) for condition and operation.6.5.1.7 For nickel-cadmium battery installations, inspectbattery temperature sensing, over-temperature warning, andbattery failure-sensing systems for pro

35、per operation. InspectF2696 142the means for disconnecting the battery(ies) for the chargingsource in the event of an over-temperature condition.6.6 Emergency Power Supply/Battery Inspection:6.6.1 Emergency power supplies or batteries shall be in-spected and functionally tested per the manufacturer

36、instruc-tions.6.6.2 Perform capacity performance tests of batteries permanufacturers instructions to ensure continued airworthiness.6.6.3 Inspect installations for condition, security, and rout-ing of wiring.6.7 Electrical Switch Inspection:6.7.1 Special attention should be given to electrical circu

37、itswitches, especially the spring-loaded type, during the courseof normal airworthiness inspection. An internal failure of thespring-loaded type may allow the switch to remain closed eventhough the toggle or button returns to the OFF position. Duringinspection, attention should also be given to the

38、possibility thatan unapproved switch substitution may have been made.6.7.1.1 With the power off, suspect aircraft electricalswitches should be checked in the ON position for opens (highresistance) and in the OFF position for shorts (low resistance)with an ohmmeter.Apower-on check can be made by chec

39、kingthe voltage drop across the switch. A voltage drop across theswitch indicates abnormal internal resistance of the switchcontacts.6.7.1.2 Any abnormal side-to-side movement of the switchshould be an alert to imminent failure even if the switch testedwas shown to be acceptable with an ohmmeter.6.7

40、.1.3 When a switch is activated, it should have a notice-able detent feel when switched. If a switch does not have adetent feel when switching, it is suspect and further inspectionshall be done before considering it airworthy. Any switch witha soft or spongy feel when switched shall be replaced.6.7.

41、1.4 Each installed switch shall be labeled to indicate itsoperation and the circuit controlled.6.8 Wires, Cables, and ClampsWires and cables shall beinspected for adequacy of support, protection, and generalcondition throughout. The desirable and undesirable features inaircraft wiring installations

42、are listed in the following andindicate conditions that may or may not exist. Accordingly,aircraft wiring shall be visually inspected for the followingrequirements. (WarningFor personal safety and to avoid thepossibility of fire, turn off all electrical power before starting aninspection or performi

43、ng maintenance of the aircraft electricalsystem.)6.8.1 Wires and cables are supported by suitable clamps,grommets, or other devices at intervals of not more than 24 in.(61 cm), except when contained in troughs, ducts, or conduits.The supporting devices shall be of a suitable size and type withthe wi

44、res and cables held securely in place without damage tothe insulation. Inspect wire and cable clamps for propertightness. Where cables pass through structure or bulkheads,inspect for proper clamping and grommets. Inspect for suffi-cient slack between the last clamp and the electronic equipmentto pre

45、vent strain at the cable terminals and to minimize adverseeffects on shock-mounted equipment.6.8.2 Mechanical standoffs shall be used to maintain clear-ance between wires and structure. Using tape or tubing is notacceptable as an alternative to standoffs for maintaining clear-ance.6.8.3 Phenolic blo

46、cks, plastic liners, or rubber grommets areinstalled in holes, bulkheads, floors, or structural memberswhere it is impossible to install off-angle clamps to maintainwiring separation. Inspect the EWIS to ensure separationbetween the wire and the hole, bulkhead, floor, or structuralmember.6.8.4 Wires

47、 and cables in junction boxes, panels, andbundles are properly supported and laced to provide propergrouping and routing.6.8.5 Clamp-retaining screws are properly secured so thatthe movement of wires and cables is restricted to the spanbetween the points of support and not on soldered or mechani-cal

48、 connections at terminal posts or connectors.6.8.6 Wire and cables are properly supported and bound sothat there is no interference with other wires, cables, andequipment.6.8.7 Wires and cables are adequately supported to preventexcessive movement in areas of high vibration.6.8.8 Insulating tubing i

49、s secured by tying, tie straps, or withclamps.6.8.9 Continuous lacing (spaced 6 in. (15 cm) apart) is notused except in panels and junction boxes where this practice isoptional. When lacing is installed in this manner, outside ofjunction boxes, it shall be removed and replaced with indi-vidual loops.6.8.10 Do not use tapes (such as friction or plastic tape) thatwill dry out in service, produce chemical reactions with wire orcable insulation, or absorb moisture.6.8.11 Insulating tubing shall be kept at a minimum andshall be used to protect wire and cable

展开阅读全文