ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf

上传人:李朗 文档编号:539414 上传时间:2018-12-07 格式:PDF 页数:7 大小:132.93KB
下载 相关 举报
ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf_第1页
第1页 / 共7页
ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf_第2页
第2页 / 共7页
ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf_第3页
第3页 / 共7页
ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf_第4页
第4页 / 共7页
ASTM F2764-2010a Standard Specification for 30 to 60 in [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications《30-60 in (750.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F2764 10aAn American National StandardStandard Specification for30 to 60 in. 750 to 1500 mm Polypropylene (PP) Triple WallPipe and Fittings for Non-Pressure Sanitary SewerApplications1This standard is issued under the fixed designation F2764; the number immediately following the designa

2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers require

3、ments and test methodsfor triple wall polypropylene pipe and fittings. The nominalinside diameters covered are 30 to 60 in. 750 to 1600 mm.1.2 The requirements of this specification are intended toprovide pipe and fittings suitable for underground use fornon-pressure sanitary sewer systems. Pipe and

4、 fittings pro-duced in accordance with this specification shall be installed incompliance with Practice D2321.1.3 This specification covers pipe and fittings with anessentially smooth interior wall, an essentially smooth exteriorwall and an annular corrugated profile middle wall (Fig. 1).1.4 The val

5、ues stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standar

6、d.1.5 The following precautionary statement applies only toSection 7 of this specification. This standard does not purportto address all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices a

7、nd deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A666 Specification for Annealed or Cold-Worked Austen-itic Stainless Steel Sheet, Strip, Plate, and Flat BarD256 Test Methods for Determining the Izod PendulumImpact Resistance of Plasti

8、csD618 Practice for Conditioning Plastics for TestingD638 Test Method for Tensile Properties of PlasticsD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plasti

9、cs by DisplacementD1238 Test Method for Melt Flow Rates of Thermoplasticsby Extrusion PlastometerD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD1600 Terminology for Abbreviated Terms Relating toPlasticsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe a

10、nd FittingsD2321 Practice for Underground Installation of Thermo-plastic Pipe for Sewers and Other Gravity-Flow Applica-tionsD2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resis-tance o

11、f Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)D2990 Test Methods for Tensile, Compressive, and Flex-ural Creep and Creep-Rupture of PlasticsD3212 Specification for Joints for Drain and Sewer PlasticPipes Using Flexible Elastomeric SealsD3895 Test Method for Oxidative-Induction T

12、ime of Poly-olefins by Differential Scanning CalorimetryD4101 Specification for Polypropylene Injection and Extru-sion MaterialsD4218 Test Method for Determination of Carbon BlackContent in Polyethylene Compounds By the Muffle-Furnace TechniqueD4389 Specification for Finished Glass Fabrics WovenFrom

13、 RovingsD6992 Test Method for Accelerated Tensile Creep andCreep-Rupture of Geosynthetic Materials Based on Time-Temperature Superposition Using the Stepped IsothermalMethodF412 Terminology Relating to Plastic Piping SystemsF477 Specification for Elastomeric Seals (Gaskets) for Join-ing Plastic Pipe

14、1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved Dec. 1, 2010. Published January 2011. Originallyapproved in 2010. Last previous edition approved in 2010 as F2764101.

15、DOI:10.1520/D276410A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr

16、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.F2136 Test Method for Notched, Constant Ligament-Stress(NCLS) Test to Determine Slow-Crack-Growth Resistanceof HDPE Resins or HDPE Corrugated Pipe2.2 AASHTO Standards:3LRFD, Section 12 AASHTO LRFD Bridge Design Speci-fication

17、s Section 12 Buried Structures and Tunnel Liners2.3 Federal Standard:4Fed. Std. No. 123 Marking for Shipment (Civil Agencies)2.4 Military Standard:4MIL-STD-129 Marking for Shipment and Storage3. Terminology3.1 Definitions are in accordance with Terminology F412and abbreviations are in accordance wit

18、h Terminology D1600,unless otherwise specified. The abbreviation for polypropyleneis PP.3.2 Definitions of Terms Specific to This Standard:3.3 triple wall, nIn this case, the triple pipe wall construc-tion provides an interior wall in the waterway, an exterior wallto the soil, and includes ribs, cor

19、rugations, or other shapes,which can be either solid or hollow, that helps brace the pipeagainst diametrical deformation.4. Ordering Information4.1 Orders for product made to this specification shallinclude the following information to adequately describe thedesired product:4.1.1 This ASTM designati

20、on and year of issue,4.1.2 Diameters,4.1.3 Total footage of each pipe diameter involved,4.1.4 Pipe laying length,4.1.5 Fitting type(s):4.1.5.1 Size and type of fittings, including mainline andbranch diameters, and4.1.5.2 Number of fittings per diameter.5. Materials and Manufacture5.1 Pipe and Fabric

21、ated FittingsPolypropylene Com-pounds Polypropylene compounds used in the manufactureof the triple wall pipe and fittings shall have the minimumproperties as shown in Table 1. Polypropylene compoundsshall be comprised of the base polypropylene virgin resin andall additives, colorants, UV inhibitors

22、and stabilizers. Condi-tioning sampling, preparation, and testing of molded specimensshall be accordance with the requirements in SpecificationD4101. For slow crack-growth resistance of the pipe corruga-tion, and inner and exterior walls, PP resins shall be evaluatedusing the notched constant ligame

23、nt stress (NCLS) test accord-ing to the procedure described in 7.7.1. The average failuretime of the five test specimens shall exceed 100 h with nosingle test specimens failure time less than 71 h. Compoundsshall be tested and validated on an annual basis or for any newformulations.5.2 Color and Ult

24、raviolet Stabilization for Pipe andFittingsThe pipe shall be colored or black. Black polypro-pylene compounds shall have between 2.0 and 3.0 percentcarbon black when tested in accordance with the procedures inTest Method D4218. Colored polypropylene compounds shallbe protected from Ultraviolet (UV)

25、degradation with UVstabilizers.5.3 Rework PlasticClean polypropylene rework plastic,generated from the manufacturers own production of theproduct and having the same minimum physical properties,may be used by the manufacturer, provided that the pipeproduced meets all the requirements of this specifi

26、cation.5.4 Elastomeric Seal MaterialsElastomeric compoundsand thermoplastic elastomeric compounds used in the manu-facture of sealing rings or gaskets shall meet the requirementsof Specification F477.3Available from American Association of State Highway and TransportationOfficials (AASHTO), 444 N. C

27、apitol St., NW, Suite 249, Washington, DC 20001,http:/www.transportation.org.4Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.FIG. 1 Typical Triple Wall Pipe ProfileTABLE 1 Polypropylene Compound

28、 PropertiesMelt Flow Rate D1238 g/10 min 0.25 230C 1.50 230CDensity D792, D1505 lb/in3(g/cm3) 0.0325 (0.900) 0.0343 (0.950)Tensile Strength at Yield D638 psi (N/mm2) 3,500 (24) 4,500 (31)Elongation at Yield D638 % (%) 5 (5) 25 (25)Flexural Modulus (1% secant) D790B psi (N/mm2) 175,000 (1,200) 275,00

29、0 (1,900)IZOD Impact Strength (730F 230C) D256 ft-lb/in2kJ/m2 23.8 (50) No BreakOxidative-Induction Time (392F 200C) D3895 min 25 200F2764 10a25.5 LubricantThe lubricant used for assembly of gasketedjoints shall have no detrimental effect of the gasket or on thepipe.5.6 Bell Retaining BandsMonolithi

30、cally formed bands inor on the external wall of the bell, when used, shall providetensile restraint to bell expansion due to gasket insertion orinternal hydrostatic pressure in accordance with 6.6.4. Thesebands shall be made of corrosive resistant materials such asfiberglass (Specification D4389) or

31、 stainless steel (Specifica-tion A666).NOTE 1Compound and material properties are typically tested tovalidate a formulation; they are not routine quality assurance tests. Usersrequiring such testing for quality assurance purposes should insert thesecriteria in their project specifications.6. General

32、 Requirements6.1 WorkmanshipThe pipe and fittings shall be homoge-neous throughout and be as uniform as commercially practicalin color, opacity, and density. The pipe walls shall be free ofcracks, holes, blisters, voids, foreign inclusions, or otherdefects that are visible to the naked eye and that

33、may affect thewall integrity. The ends shall be cut cleanly and squarelythrough valleys.6.1.1 Visible defects, cracks, creases, splits, in pipe are notpermissible.6.2 Dimensions and Tolerance:6.2.1 Nominal SizeThe nominal size for the pipe andfittings shall be the inside diameter shown in Table 2.6.

34、2.2 Minimum Inside DiameterThe minimum inside di-ameter shall be as shown in Table 2, when measured inaccordance with section 7.3.3. In no case shall the manufac-turers stated inside diameter minus the tolerance in Table 2 beless than the required minimum inside diameter.NOTE 2The manufacturers stat

35、ed inside diameter is the nominaldiameter plus or minus the inside diameter tolerances. The minimuminside diameter is the smallest diameter the pipe can be with thesetolerances and is used for the hydraulic design of the pipe.NOTE 3The outside diameters and the corrugation pitch of productsmanufactu

36、red to this specification are not specified; therefore, compatibil-ity between pipe and fittings made to this specification from differentmanufacturers should be verified.6.2.3 Laying LengthThe pipe shall be supplied in anylaying length agreeable to both the owner and the manufac-turer. Laying lengt

37、h shall not be less than 99 % of statedquantity when measured in accordance with 7.3.2.6.2.4 Minimum Wall, Crest, Valley and Liner ThicknessThe minimum thickness of pipe sections shall meet therequirements given in Table 2 when measured in accordancewith 7.3.3.6.3 Pipe StiffnessMinimum pipe stiffnes

38、s at 5 % deflec-tion shall meet the requirements given in Table 2 when testedin accordance with 7.4.NOTE 4The 5 % deflection criterion, which was selected for testingconvenience, is not a limitation with respect to in-use deflection. Theengineer is responsible for establishing the acceptable deflect

39、ion limit.6.4 Pipe FlatteningThere shall be no evidence of split-ting, cracking, breaking, separation of seams, separation of theouter and inner wall, or combinations thereof, when tested inaccordance with 7.5.6.5 Pipe Impact StrengthThere shall be no evidence ofsplitting, cracking, breaking, separa

40、tion of seams, separation ofthe outer and inner wall, or combinations thereof, whenconditioned in accordance with 7.1 and tested in accordancewith 7.6 and examined under normal light and the unaided eye.The minimum pipe impact strength at 73F (23C) shall be 140ft-lbf (190 J).6.6 Fittings and Joining

41、 Systems:6.6.1 Only fittings and joining systems supplied or recom-mended by the pipe manufacturer shall be used. Fittings shallbe installed in accordance with the manufacturers recommen-dations and meet the same material requirements as the pipe.NOTE 5Fittings may be fabricated from the pipe by a v

42、ariety ofprocesses including hot plate welding, spin welding or other processes.6.6.2 The joining system(s) shall be of a design thatpreserves alignment during construction and prevents separa-tion at the joints while maintaining watertight requirements inaccordance with 6.6.3.6.6.3 Pipe and fitting

43、s shall have a watertight bell/spigotjoint that complies with the laboratory tests defined anddescribed in Test Method D3212 and utilizes a gasket thatcomplies with the requirements of Specification F477. Notethat special provisions must be taken in order to join field cutpipe that meets the require

44、ments of Specification D3212. Anycomponent used in the joining material shall be resistant toeffluents being carried in the pipe.6.6.4 Monolithic retaining bands utilized for the bells onjoining systems shall have a structural tensile resistance oftwice the operational pressure of the pipeline, but

45、no less than21.6 psi, when tested in accordance with 6.6.3. In lieu of a fullTABLE 2 Pipe Stiffness and Pipe DimentionsPipe InsideDiameterMinimumInsideDiameterInsideDiameterTolerancesMinimumPipe Stiffnessat 5 %DeflectionMinimumInner LinerThicknessMinimumOuter LinerThicknessMinimumValleyThicknessMini

46、mumCrownThicknessin. mm in. mm in. mm lb/in/in kPa in. mm in. mm in. mm in. mm30 750 29.62 752 +0.18/- 0.18 +4.6/-4.6 46 317 0.070 1.8 0.070 1.8 0.081 2.1 0.115 2.936 900 35.40 899 +0.21/- 0.21 +5.3/-5.3 46 317 0.095 2.4 0.095 2.4 0.109 2.8 0.165 4.242 1050 41.31 1049 +0.22/- 0.22 +5.6/-5.6 46 317 0

47、.105 2.7 0.105 2.7 0.121 3.1 0.165 4.248 1200 47.31 1201 +0.27/- 0.27 +6.9/-6.9 46 317 0.105 2.7 0.105 2.7 0.126 3.2 0.170 4.354 1350 53.32 1354 +0.27/- 0.27 +6.9/-6.9 46 317 0.105 2.7 0.105 2.7 0.131 3.3 0.170 4.360 1500 59.30 1506 +0.31/- 0.31 +7.9/-7.9 46 317 0.105 2.7 0.105 2.7 0.137 3.5 0.210 5

48、.3F2764 10a3Specification D3212 joint test, it shall be acceptable to exertonly the bell to the internal pressure by either mechanical orhydrostatic means for the appropriate test time in SpecificationD3212. Bell retaining bands, when used, shall show no signs ofcracking, separation, splitting or de

49、lamination from the pipeduring this test.6.6.5 A joint proof-of-design test shall be conducted inaccordance with 7.10. This test is a one time validation test forthe specific pipe diameter, gasket and joint configurationsupplied by the manufacturer.6.7 Creep Rupture StrengthSpecimens fabricated in thesame manner and composed of the same materials as thefinished pipe shall have a 50-year creep rupture tensile strengthat 73F (2