ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf

上传人:registerpick115 文档编号:541259 上传时间:2018-12-08 格式:PDF 页数:13 大小:153.87KB
下载 相关 举报
ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf_第1页
第1页 / 共13页
ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf_第2页
第2页 / 共13页
ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf_第3页
第3页 / 共13页
ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf_第4页
第4页 / 共13页
ATIS 0600307-2014 Fire Resistance Criteria - Ignitability Requirements for Equipment Assemblies Ancillary Non-Metallic Apparatus and Fire Spread Requirements for Wire and Cable.pdf_第5页
第5页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 AMERICAN NATIONAL STANDARD FOR TELECOMMUNICATIONS ATIS-0600307.2014 FIRE RESISTANCE CRITERIA IGNITABILITY REQUIREMENTS FOR EQUIPMENT ASSEMBLIES, ANCILLARY NON-METALLIC APPARATUS, AND FIRE SPREAD REQUIREMENTS FOR WIRE AND CABLE As a leading technology and solutions development organization, ATIS bri

2、ngs together the top global ICT companies to advance the industrys most-pressing business priorities. Through ATIS committees and forums, nearly 200 companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of serv

3、ice, billing support, operations, and more. These priorities follow a fast-track development lifecycle from design and innovation through solutions that include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the Ame

4、rican National Standards Institute (ANSI). ATIS is the North American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a founding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, a

5、nd a member of the Inter-American Telecommunication Commission (CITEL). For more information, visit . AMERICAN NATIONAL STANDARD Approval of an American National Standard requires review by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the st

6、andards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requir

7、es that all views and objections be considered, and that a concerted effort be made towards their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, mar

8、keting, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or aut

9、hority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National St

10、andard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling

11、or writing the American National Standards Institute. Notice of Disclaimer federal, state, or local codes; or other user specified standards or documents. Values of units of measure as indicated in this standard are shown in both SI and British Engineering units. Where a unit of measure is followed

12、by a value enclosed in parentheses, the second value may be an approximation of the first value. In this standard, the first-stated value is the requirement. ATIS-0600307.2014 2 2 Normative References The following standards contain provisions that, through reference in this text, constitute provisi

13、ons of this American National Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this American National Standard should investigate the most recent editions of the standards cited below. Check with ATIS f

14、or information on applicability of any revision of the cited references as they apply to this standard. ATIS-0600319.2008, Equipment Assemblies - Fire Propagation Risk Assessment Criteria.1ANSI UL1694-2010, Tests for Flammability of Small Polymeric Component Materials.2ANSI/UL 746C-2012, Polymeric m

15、aterials Use in Electrical Equipment Evaluations.2ASTM D2863-10, Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index). 3NFPA 70-(2011 Edition), National Electric al Code.4ASTM E 84 -12, Test for Surface Burning Characteristi

16、cs of Building Materials.3ANSI/UL 94-2012, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.2NFPA 262 (2011 Edition), Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces.4UL 510-2005 (R2008), Polyvinyl Chloride, Polyethylene, and Rubber I

17、nsulating tape.2IEC 60695-11-5(2004-12), Fire hazard testing Part 11-5: Test methods, needle-flame test method- Apparatus, confirmatory test arrangement and guidance5ANSI/UL 723 -2005, Test for Surface Burning Characteristics of Building Materials.2ANSI/UL 900-2012, Air Filter Units IEEE 1202-2006,

18、IEEE Standard for Flame-Propagation Testing of Wire and Cable.6ANSI/UL 1441-2005 (R2009), Coated Electrical Sleeving.2ANSI/UL 1581-2011, Reference Standard for Electrical Wires, Cables, and Flexible Cords. 2ANSI/UL 1666-2007 (R2011), Test for Flame Propagation Height of Electrical and Optical-Fiber

19、Cables Installed Vertically in Shafts.2ANSI/UL 1685-2010, Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables.2ANSI/UL 1694-2010, Tests for Flammability of Small Polymeric Component Materials.2CAN/CSA-C22.2 No. 0.3-09 (rev. 2010), Test methods for electrical

20、 wires and cables. 7ANSI/UL 2024-2011 Signaling, Optical Fiber and Communications Raceways and Cable Routing Assemblies.21This document is available from the Alliance for Telecommunications Industry Solutions at . 2This document is available from Underwriters Laboratories, Inc. (via comm2000). 3This

21、 document is available from ASTM International . 4This document is available from the National Fire Protection Association (NFPA). 5This document is available from the International Electrotechnical Commission. 6This document is available from the Institute of Electrical and Electronics Engineers (I

22、EEE). 7This document is available from CSA Group . ATIS-0600307.2014 3 ASTM E 814-11a, Standard Test Method for Fire Tests of Penetration Fire Stop Systems.3ANSI/UL 1479-2010, Fire Tests of Through-Penetration Fire Stops.2 3 Definitions, Abbreviations, however, they shall meet one of the other appro

23、priate options contained in 4.1.2. See 4.1.1 and 4.1.2 regarding requirements for items such as plugs, sockets, jacks, terminal blocks, etc., which may form part of an enclosure. Discrete (non-electrically energized) components with overall dimensions of 1/4 in (6.3 mm) x 1/4 in (6.3 mm) x 1/4 in (6

24、.3 mm) or less, or constituting a fuel load of 1 g (0.035 oz) or less, are exempt from the requirements of 4.1.2 and 4.1.3. If such components are grouped in close proximity and their total mass exceeds 1 g (0.035 oz), they shall comply with 5.2. 4.1.4 Interconnect Wire Individual interconnect wire

25、and cable (copper and optic fiber) used within equipment assemblies shall satisfy the requirements of VW-1 as specified in ANSI/UL 1581. Any wire and cable exterior to an equipment assembly shall meet the requirements of 4.2. 4.2 Fire Spread Requirements for Wire CAN/CSA-C22.2 No. 0.3; or IEEE 1202. Examples of cable types meeting these requirements are: CM, CL2, CL3, OFN, OFC, MP, FPL, and CATV, in addition to those specified in 4.2.1 and 4.2.2. 4.2.4 AC-Powered Wiring the second value is based on three applications of the ignition source.