BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf

上传人:orderah291 文档编号:543852 上传时间:2018-12-09 格式:PDF 页数:10 大小:433.94KB
下载 相关 举报
BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf_第1页
第1页 / 共10页
BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf_第2页
第2页 / 共10页
BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf_第3页
第3页 / 共10页
BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf_第4页
第4页 / 共10页
BS 3762-3 10-1989 Analysis of formulated detergents - Quantitative test methods - Methods for determination of short-chain alkylbenzenesulphonates content《配制洗涤剂的分析 定量试验方法 短链烷基苯磺酸盐含.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS3762-3.10: 1989 Analysis of formulated detergents Part3: Quantitative test methods Section3.10 Methods for determination of short-chain alkylbenzenesulphonates content NOTEIt is recommended that this Section be read in conjunction with the information in the“General introduction”,

2、 published separately as BS3762-0. UDC661.185.6:620.1BS3762-3.10:1989 This British Standard, having been prepared under the directionof the Chemicals Standards Committee, was published under the authorityofthe Board of BSIandcomesinto effect on 28February1989 BSI11-1999 The committees responsible fo

3、rthis British Standard are shown in Part0. The following BSI references relate to the work on this standard: Committee reference CIC/34 Draft for comment87/51478 DC ISBN 0 580 17077 2 Foreword This Section of BS3762 has been prepared under the direction of the Chemicals Standards Committee and super

4、sedes method B8 of BS3762:1964, which is being deleted by amendment. This standard describes methods of test only and should not be referred to as a specification defining limits of purity. Reference to the standard should indicate that the method of test used is in conformity with BS3762-3.10. A Br

5、itish Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a fr

6、ont cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publicatio

7、n Amd. No. Date of issue CommentsBS3762-3.10:1989 BSI 11-1999 i Contents Page Foreword Inside front cover 1 Scope 1 2 Method A: spectrometry 1 3 Method B: high performance liquid chromatography (HPLC) 2 4 Precision 3 5 Test report 3 Figure 1 Typical chromatogram 4 Publications referred to Inside bac

8、k coverii blankBS3762-3.10:1989 BSI 11-1999 1 1 Scope This Section of BS3762 describes two methods for the determination of the toluenesulphonates or xylenesulphonates content of formulated detergents. In method A, the alkylbenzenesulphonates content is determined spectrometrically as sodium toluene

9、sulphonate or as sodium xylenesulphonate, using calibration graphs prepared with appropriate reference materials. Method B, which is based on a reversed-phase high-performance liquid chromatographic (HPLC) separation technique, separates and quantifies mixtures. Method A is for use if no HPLC equipm

10、ent is available, or if mixtures of toluenesulphonates and xylenesulphonates are not suspected. Method A is not applicable to samples containing compounds that absorb radiation at220nm and that are not extracted by diethyl ether, e.g.alkylphenolethoxylates. Method B may be used with samples that con

11、tain single or mixed compounds. NOTEThe titles of the publications referred to in this Section are listed on the inside back cover. 2 Method A: spectrometry 2.1 Principle Toluenesulphonate or xylenesulphonate is determined by ultraviolet spectrometry after extraction of alkylarylsulphonates with die

12、thyl ether from a solution of the product in dilute hydrochloric acid solution. 2.2 Reagents The reagents other than those described in2.2.4 and2.2.5 shall be of a recognized analytical grade. Water complying with grade3 of BS3978 shall be used throughout. 2.2.1 Diethyl ether 2.2.2 Acetone 2.2.3 Mix

13、ed solvent. Mix one volume of absolute ethanol with one volume of acetone. 2.2.4 Sodium toluenesulphonate, pure. NOTEThis will normally be sodium p-toluenesulphonate but may be another isomer. 2.2.5 Sodium xylenesulphonate, pure. NOTEThis will normally be a mixture of isomers. 2.2.6 Sodium hydroxide

14、 solution,100g/L. 2.2.7 Hydrochloric acid solution, c (HCl)=6mol/L. 2.2.8 Hydrochloric acid solution, c (HCl)=4mol/L. 2.2.9 Narrow range indicator paper, pH4 to6. NOTEA correctly calibrated pH meter is a suitable alternative. 2.3 Apparatus Ordinary laboratory apparatus and the following are required

15、. 2.3.1 Spectrometer, suitable for measurements between200nm and280nm. 2.3.2 Silica cells, optical path length10mm. 2.3.3 Sintered glass filter, complying with grade P16 of BS1752. 2.3.4 One-mark volumetric flasks,100mL and250mL, complying with grade A of BS1792. 2.4 Procedure 2.4.1 Test solution. W

16、eigh, to the nearest0.01g, about10g of well mixed sample into a beaker. Dissolve it in water, transfer the solution quantitatively to a250mL one-mark volumetric flask(2.3.4) and dilute to the mark with water. Mixwell. 2.4.2 Removal of alkylarylsulphonates CAUTION. Perform all extractions with diethy

17、l ether with due regard to possible fire hazard and preferably in an area free of ignition sources. Transfer by pipette50mL of the test solution(2.4.1) to a separating funnel, add25mL of the hydrochloric acid solution(2.2.7) and extract with50mL of the diethyl ether(2.2.1). Transfer the aqueous (low

18、er) phase to a second separating funnel and retain the ether phase. Repeat the extraction of the aqueous phase with a further three50mL portions of the diethyl ether. Combine the four diethyl ether extracts in a separating funnel and wash three times with25mL portions of the hydrochloric acid soluti

19、on(2.2.8). Combine the wash liquors and extract with50mL of the diethyl ether. Discard the ether extract. 2.4.3 Extraction of short-chain alkylbenzenesulphonates. Evaporate to dryness the aqueous phase and washings recovered from the extraction, preferably using a rotary evaporator. NOTEThe washings

20、 will be saturated with diethyl ether, so suitable precautions should be taken to allow for a possible hazard from the evolution of diethyl ether vapour. Dissolve the residue in a little water and neutralize with the sodium hydroxide solution(2.2.6) until the pH value is4.5, as indicated by the narr

21、ow range indicator paper(2.2.9). Evaporate to dryness, add5mL of the acetone(2.2.2), evaporate to dryness again and repeat twice more with fresh5mL portions of the acetone.BS3762-3.10:1989 2 BSI 11-1999 Add50mL of the mixed solvent(2.2.3) to the residue, heat on a steam bath or hot plate at100 C for

22、 about10min, then remove and allow insoluble matter to settle. Decant the solution through the sintered glass filter(2.3.3), to which gentle suction is applied. Extract the residue with four successive30mL portions of the mixed solvent, passing each in turn through the sintered glass filter. Wash th

23、e filter three times with mixed solvent, heated to about50 C. Evaporate the filtrate and washings to dryness and dissolve the residue in water. Transfer the solution quantitatively to the100mL one-mark volumetric flask(2.3.4) and dilute to the mark with water. Mixwell. 2.4.4 Spectrometric analysis.

24、Produce a calibration graph by preparing a range of solutions of toluenesulphonate or xylenesulphonate reference material(2.2.4 or2.2.5), as appropriate. The concentrations should cover a range corresponding to absorbances of0.0 to approximately0.8. Determine the absorbance of each solution at220nm,

25、 using the silica cells(2.3.2), and with water as a reference blank. Plot a calibration graph of concentration versus absorbance. NOTE 1Four or five solutions should be used. Determine the absorbance at220nm of the solution obtained from2.4.2, using the silica cells(2.3.2), and with the distilled wa

26、ter as a reference blank. Ifnecessary, prepare serially diluted solutions to bring the absorbance readings within the range of the calibration graph. Determine the concentration of toluenesulphonate or xylenesulphonate in the test solution from the graph. NOTE 2Toluenesulphonates may be distinguishe

27、d from xylenesulphonates as they have different ultraviolet spectra. Thetoluene derivatives give maxima at220nm,256nm,262nm and268nm and the xylene derivatives give maxima at220nm,272nm and278nm. 2.5 Expression of results The toluenesulphonate or xylenesulphonate content, expressed as a percentage b

28、y mass as the sodium salt, is given by the following expression: 3 Method B: high performance liquid chromatography (HPLC) 3.1 Principle Separation of the desired compound by reversed-phase HPLC, with ultraviolet detection and comparison of the sample peak areas with those derived from suitable exte

29、rnal reference standards. 3.2 Reagents The reagents other than those described in3.2.3 and3.2.4 shall be of a recognized analytical grade. Water complying with grade1 of BS3978 shall be used throughout. NOTESolvents and water of HPLC grade are commercially available and may be used. 3.2.1 Methanol 3

30、.2.2 Mobile phase, of a composition to effect suitable elution of the desired species. An example is methanol/water 25:75(V/V), containing ammonium acetate(10g/L of methanol/water). 3.2.3 Sodium toluenesulphonate, pure. NOTEThis will normally be sodium p-toluenesulphonate but may be another isomer.

31、3.2.4 Sodium xylenesulphonate, pure. NOTEThis will normally be a mixture of isomers. 3.3 Apparatus Ordinary laboratory apparatus and the following are required. 3.3.1 High performance liquid chromatograph, with the following elements. 3.3.1.1 Stainless steel column, of suitable dimensions, typically

32、100mm long and of4.6mm internal diameter, packed with octadecyl-modified fully end-capped silica-based packing of54m mean particle size, or similar suitable packing. NOTE 1Such columns are available commercially. NOTE 2A short precolumn to protect the analytical column may be used. This should be pa

33、cked with material similar in surface modification to that in the main column. 3.3.1.2 Injection valve, fitted with a fixed volume104L loop, or capable of operation in the partial loop filling mode with a loop volume of not less than204L. NOTEAlternatively, a suitable automatic injection system may

34、be used. 3.3.1.3 Ultraviolet detector, capable of measuring absorbance at254nm. 3.3.2 Syringe, of254L,504L or1004L capacity, with needle to suit the loading requirements of the injection valve, unless automatic injection is used. 3.3.3 Chart recorder or plotter 3.3.4 Peak integrator, preferably elec

35、tronic. 3.3.5 One-mark volumetric flasks,100mL and250mL, complying with BS1792. where d is the dilution factor (unity if no dilution was used in2.4.4); c is the concentration of sodium toluenesulphonate or sodium xylenesulphonate found from sample absorbance and the calibration graph (see2.4.4) (ing

36、/100mL); m is the mass of sample taken (see2.4.1) (ing). 500d c m -BS3762-3.10:1989 BSI 11-1999 3 3.4 Procedure 3.4.1 Test solution. Weigh, to the nearest0.01g, about10g of well mixed sample into a beaker. Dissolve it in water, filter it if necessary using a fine glass-fibre filter paper, transfer i

37、t quantitatively to a250mL one-mark volumetric flask(3.3.5) and dilute to the mark with water. Mix well. 3.4.2 Preparation of external reference standard solutions. Weigh, to the nearest0.0002g, about0.1g of the sodium toluenesulphonate(3.2.3) or weigh, to the nearest0.001g, about0.5g of the sodium

38、xylenesulphonate(3.2.4) as required, into a100mL beaker. Dissolve the reference material in water, transfer it quantitatively to a100mL one-mark volumetric flask(3.3.5) and dilute to the mark with water. Mix well. NOTE 1Make both solutions separately if both types of sulphonate are to be determined.

39、 NOTE 2For successful calibration using single-level reference standards, the system response has to be linear. It is recommended that a suitable serial dilution of the reference standard and sample solutions be made if the absorbance figures obtained exceed1.0. If there is any doubt concerning syst

40、em linearity, make up a series of reference standard solutions at suitable concentrations to produce a graph of response versus concentration. 3.4.3 Chromatographic conditions. The following conditions are given as examples and have been found to be suitable. 3.4.4 Chromatographic analysis. Commence

41、 pumping the modile phase(3.2.2) at the chosen flow rate and allow the conditions to stabilize. Using the appropriate procedure for the injection system, load the sample loop with the required reference standard solution(3.4.2). Simultaneously start data collection by the integrator(3.3.4) and opera

42、te the injection valve(3.3.1.2). Allow the chromatogram to develop and obtain the peak areas from the integrator. Repeat the procedure for the sample solution. An example of a chromatogram that may be obtained, depending on the species present, is shown inFigure 1. After a number of analyses, typica

43、lly six to ten, wash the column free of retained material, including long-chain alkylbenzenesulphonates. Change the eluent to the methanol(3.2.1) and pump at the same or higher flow rate until conditions have restabilized. Change the eluent back to the mobile phase(3.2.2) and allow conditions to sta

44、bilize again at the chosen flow rate before further analyses. 3.5 Expression of results The toluenesulphonate or xylenesulphonate content, expressed as a percentage by mass as the sodium salt, is given by the following expression: 3.6 Typical chromatogram Figure 1 shows a chromatogram that is typica

45、l of those obtained from a sample containing impure sodium xylenesulphonate, with sodium toluenesulphonate included in the impurities. 4 Precision No precision data are available. 5 Test report The test report shall include the following information: a) a reference to this British Standard, i.e.BS37

46、62-3.10:1989; b) a reference to the test method used, i.e.methodA or method B; c) the results expressed in accordance with2.5 or3.5, including the reference standard used, i.e.either as sodium toluenesulphonate or as sodium xylenesulphonate, and the isomeric nature of the reference standard (this wi

47、ll normally be as p-toluenesulphonate or as xylenesulphonate, mixed isomers); d) a complete identification of the sample. Eluent flow rate 1.5mL/min Detector wavelength 254nm (alternatively220nm giving greater sensitivity, requiring different dilutions) Injection volume 104L where a 2 is the peak ar

48、ea for the sample, using the same peaks as the reference standard, identified by retention time; m 1 is the mass of the reference material weighed in3.4.2 (ing); a 1 is the peak area for the reference standard (for xylenesulphonate, the total of the peaks due to the isomers); m 2 is the mass of the

49、sample weighed in3.4.1 (ing). 250a 2 m 1 a 1 m 2 -BS3762-3.10:1989 4 BSI 11-1999 Figure 1 Typical chromatogramBS3762-3.10:1989 BSI 11-1999 Publications referred to BS1752, Specification for laboratory sintered or fritted filters including porosity grading. BS1792, Specification for one-mark volumetric flasks. BS3978, Specification for water for laboratory use. BS3762-3.10: 1989 BSI 389 Chiswick High Road London W4 4AL BSIBritishStandardsInstitution BSI is the independent national body responsibl

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1