BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf

上传人:eveningprove235 文档编号:547626 上传时间:2018-12-09 格式:PDF 页数:32 大小:723.64KB
下载 相关 举报
BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf_第1页
第1页 / 共32页
BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf_第2页
第2页 / 共32页
BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf_第3页
第3页 / 共32页
BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf_第4页
第4页 / 共32页
BS 9210 N007-1-1976 Detail specification for radio frequency connectors (type SMB) - Unsealed soldered captive contact 50 $2I snap-on couplings - Full assessment level《射频连接器(SMB型)的.pdf_第5页
第5页 / 共32页
亲,该文档总共32页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS9210 N007-1:1976 Detail specification forradio frequency connectors (typeSMB) Unsealed,soldered, captive contact,50 7, snap-on couplings Full assessment level UDC 621.37/39:621.315.683BS9210N007-1:1976 BSI04-2000 ISBN 0 580 09154 6 A British Standard does not purport to include al

2、l the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andi

3、i, pages1 to26 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBS9210N007-1:1976 BSI 04-2000 i Contents P

4、age 1 Physical characteristics 2 2 Ratings (including limiting conditions of use) and characteristics 3 3 Related documents 4 4 Additional information 4 5 Marking of the connectors and packages 4 6 Ordering information 4 7 Control drawings 5 8 Inspection requirements 5 Appendix A Outline drawings 17

5、 Appendix B Piercings for metal panels printed wiring boards and overlap dimensions 25ii blankBS9210N007-1:1976 BSI 04-2000 1 ELECTRONIC COMPONENTS OF ASSESSED QUALITY: DETAIL SPECIFICATION Typical outlines, styles06-03 and07-02 RADIO FREQUENCY CONNECTOR FULL ASSESSMENT LEVEL TYPE SMB UNSEALED, SOLD

6、ERED, CAPTIVE CONTACT507 (SNAP-ON COUPLING) For other styles and dimensions seeAppendix A.BS9210N007-1:1976 2 BSI 04-2000 1 Physical characteristics 1.1 1.2 Body finish Gold (Au), Cadmium (Cd), Bright Nickel alloy (Ni-). NOTEGalvanic corrosion may occur when connectors with dissimilar finishes are m

7、ated. 1.3 Centre contact finish. Gold (Au). Connector style Description Mass (grams) max. Connector variant Cables BS2316/(URM no.) 01-02 Connector coupler, free, straight 3.5 matched 02-02 Connector fixed, straight,4-hole fixing, solder bucket 3.0 AB 110 AC 95 AE 109,116 05-02 Connector fixed, sing

8、le hole mounting, solder bucket 1.5 Unmatched 06-03 Connector free, straight 3.5 ZZ Equipment wire 07-02 Connector fixed, straight, single hole mounting, cable outlet 3.1 08-03 Connector free, right angle 5.0 10-02 Connector fixed, right angle,4-hole fixing solder bucket 12-02 Connector fixed, right

9、 angle, single hole mounting, solder bucket 5.0 13-02 Connector fixed, straight, printed circuit board mounting 4.0 14-02 Connector fixed, right angle, printed circuit board mounting 5.5 18-04 Adaptor connector fixed, straight, single hole mounting 3.0 18-05 Adaptor connector fixed, straight, single

10、 hole mounting 5.0 98-12 Cover, protective, for connector fixed and connector coupler, free 3.0 99-12 Cover, protective, for connector free 3.0BS9210N007-1:1976 BSI 04-2000 3 2 Ratings (including limiting conditions of use) and characteristics Nominal characteristic impedance 507 Matched variants Un

11、matched variants Reflection coefficient (and v.s.w.r.) maximum Up to4GHz a) Straight cable outlet styles 0.19(1.46) Not measured b) Right-angle styles and adaptors, straight 0.25(1.69) c) Solder-bucket styles Not measured Capacitance (maximum) (solder-bucket styles only) 5pF R.F. shunt resistance (m

12、inimum) (solder-bucket styles only) 1 M7 at30MHz Working voltage (d.c. or a.c. peak) Inner conductor to shell a) At sea level 500V b) At altitude of20km(44mbar a ) 100V Proof voltage (d.c. or a.c. peak) a) At sea level 1500V b) At altitude of20km(44mbar) 300V Current rating (maximum) 0.25A Power rat

13、ing b a 1mbar=10 2 N/m 2 =100Pa b As power is dependent on frequency and cable type, for information on power rating refer to the manufacturer.BS9210N007-1:1976 4 BSI 04-2000 3 Related documents BS2011, “Methods for the environmental testing of electronic components and electronic equipment”. BS2316

14、, “Radio-frequency cables”. BS6000, “Guide to the use of BS6001. Sampling procedures and tables for inspection by attributes”. BS6001, “Sampling procedures and tables for inspection by attributes”. BS9000, “General requirements for electronic components of assessed quality”. BS9210, “Radio frequency

15、 connectors of assessed quality: generic data and methods of test”. 4 Additional information (Not for inspection purposes) For piercings for metal panels and overlap dimensions seeAppendix B. 5 Marking of the connectors and packages The marking of the component and package shall be in accordance wit

16、h1.1.6 of BS9210. Assembly and cable mounting instructions shall be included in every individual package of connector piece parts. 6 Ordering information In accordance with the requirements of1.1.15 of BS9210, orders for connectors and their accessories covered by this specification shall contain th

17、e following information. a) The number of this specification i.e.BS9210 N007. b) Style as in1.1, e.g.0102. c) Variant as in1.1, e.g.AB d) Climatic category, i.e.55/155/21. e) Body finish, e.g.gold (Au). f) Any additional information, e.g.fixing hole details, any special marking, or packaging require

18、ments. Example. BS9210 N007/0102/AB/55/155/21/Au. Before conditioning After conditioning Contact resistance, maximum 5m7 10m7 Outer conductor continuity, maximum 2m7 5m7 Insulation resistance, minimum 5G7 500M7 Vibration severity Frequency range 10Hz to500Hz Displacement 0.75mm Cross over at Acceler

19、ation 98m/s 2 approximately60Hz Duration 30min Shock severity Not applicable Bump severity 4000 at390m/s 2 Climatic category 55/155/21 Resistance to test prod damage Not applicable Impact severity (free specimens only) 5 impacts at1m Engagement and separation forces Engagement,60N maximum Separation

20、,60N maximum 8N minimum BS9210N007-1:1976 BSI 04-2000 5 7 Control drawings Control drawings, reference BS9210 N007-2, are available from BSI. NOTENormally required by manufacturers and inspectorates only. 8 Inspection requirements 8.1 Unless otherwise stated in the table of tests the provisions of8.

21、2, 8.3 and8.4 of this specification shall apply. 8.2 Contact resistance and outer conductor continuity for each mated pair shall be measured using the “light current” method specified in1.2.4.3.3 1) of BS9210. When testing the outer conductor continuity of panel mounted styles, where the connector s

22、hell is electrically connected to a mounting plate (see1.2.1.1 of BS9210), the continuity test shall include a measurement between cable braid(s) and the mounting plate. The initial contact resistances for each mated pair of contacts and any outer conductor continuity shall not exceed2m7 respectivel

23、y. Resistances after conditioning shall not exceed10m7 and5m7 respectively. 8.3 Insulation resistance measurements between inner conductor and shell shall be made at500 50V d.c. 8.4 Voltage proof measurements shall be made at1500 100V d.c. or peak a.c.(40Hz to60Hz). There shall be no breakdown or fl

24、ashover. 8.5 For tests in subgroups C3, C5, D3 (iii), and D3 (v), involving exposure to the upper temperature category, it is essential that cable having a compatible temperature capability shall be used. 8.6 Due to the nature of the accessories referred to in note1 of this specification at the end

25、of this table, certain tests are not possible, e.g.contact resistance tests are not applicable to protective covers styles98-12 and99-12 either before or after conditioning. 8.7 Samples submitted to tests which are marked as “(D)” shall not be accepted for release under BS9000 (see2.6.5 of BS9000-1)

26、. 8.8 The tests or measurements prescribed in BS9210 after environmental conditioning are omitted between the environmental conditionings where these form part of a sequence in accordance with1.2.6 of BS9210. The appropriate tests are included at the end of each test sequence. Inspection BS9210:1971

27、 reference and conditions of test Performance requirements GROUP A To be applied on a sampling basis lot-by-lot. Subgroups A2, A3 and A4 are not applicable Subgroup A0 100% inspection (seenote1 of this specification) Visual examination 1.2.2 1) Either on assembled components or on contents of packag

28、es As in1.2.2 1) of BS9210 Subgroup A1 Inspection level S-3, AQL1.5% (seenote1 of this specification) Visual examination 1.2.2 2) Either on assembled components or on contents of packages As in 1.2.2 2) of BS9210 Subgroup A5 CTR information 1.1.11 Attributes information for subgroup A1 GROUP B To be

29、 applied on a sampling basis lot-by-lot. Subgroups B3, B5, B6 and B7 are not applicable. (The specimens used for subgroups B1 and B2 may also be used for subgroup B4). Connectors shall be assembled in accordance with the instructions supplied by the manufacturer NOTESSeeend of table.BS9210N007-1:197

30、6 6 BSI 04-2000 Inspection BS9210:1971 reference and conditions of test Performance requirements GROUP B (Contd) Subgroup B1 Inspection level S-3, AQL1% Compatibility-mechanical (assurance) 1.2.5.9 2) Seenote1 of this specification As in1.2.5.9 2) of BS9210 Subgroup B2 (D) Inspection level S-3, AQL4

31、% Soldering 1.2.6.1 Soldering iron method Bit size3mm Iron size (b) Inner contact for all styles; also mounting spills for styles13-02 and14-02 There shall be no damage or loosening of parts Insulation resistance 1.2.4.6 As in8.3 of this specification U5G7 Voltage proof 1.2.4.7 As in8.4 of this spec

32、ification As in8.4 of this specification Subgroup B4 (D) Inspection level S-3, AQL4% Engagement and separation 1.2.5.5 Seenote1 of this specification As in clause2 of this specification Gauge retention force 1.2.5.2 Seecontrol drawings BS9210 N007-2, for details of gauges As in1.2.5.2 of BS9210 Subg

33、roup B8 CTR information 1.1.11 Attributes information for subgroups B1, B2, and B4 GROUP C Applied at three-monthly intervals except when group D tests are due. In addition the issue number of the manufacturers drawing list shall be checked against that in the qualification approval application or c

34、ertificate. Specimens used for subgroup C1 may also be used for subgroups C3 and C5. Subgroups C2 and C4 are not applicable Subgroup C1 Inspection level S-3, AQL1% Outline dimensions and mass 1.2.3.1 Seenote1 of this specification As specified in1.1 and Appendix A of this specification Subgroup C3 (

35、D) Inspection level S-3, AQL4% 8.5, 8.8, notes1 and2 of this specification apply to tests in this subgroup. Connectors shall be assembled as for group B. NOTESSeeend of table.BS9210N007-1:1976 BSI 04-2000 7 Inspection BS9210:1971 reference and conditions of test Performance requirements Subgroup C3

36、(Contd) Test prod damage Test not to be applied Rapid change of temperature 1.2.6.9 55 C and+155 C Damp heat, steady state 1.2.6.8 Severity40 2 C for4days Polarizing voltage605Vd.c. Innerconductor to be positive Working voltage500 50V d.c. ora.c. peak As in 1.2.6.8 of BS9210 Final measurements Conta

37、ct resistance 1.2.4.3 As in8.2 of this specification (mated connectors not separated) (Not applicable to styles referred to in note1 of this specification) As in8.2 of this specification Outer conductor continuity 1.2.4.4 As in8.2 of this specification (mated connectors not separated) (Not applicabl

38、e to styles referred to in note1 of this specification) As in8.2 of this specification Subgroup C3 (D) Insulation resistance 1.2.4.6 As in8.3 of this specification (Not applicable to styles referred toinnote1 of this specification) W 500M7 Voltage proof 1.2.4.7 As in8.4 of this specification Not app

39、licable to styles referred toinnote1 of this specification As in8.4 of this specification Visual inspection 1.2.2 As in1.2.2 of BS9210 Engagement and separation 1.2.5.5 Forces as in clause2 of this specification Subgroup C5 (D) Inspection level S-3, AQL4% 8.5, 8.8, notes1 and2 of this specification

40、apply to tests in this subgroup. Connectors shall be assembled as for subgroup B Mechanical endurance 1.2.7.1 50 operations at not more than15/min followed by High temperature endurance 1.2.7.2 Severity155 5 C for250h with noelectrical load Final measurements Insulation resistance 1.2.4.6 As in8.3 o

41、f this specification Not applicable to styles referred toinnote1 of this specification W 500M7 Contact resistance 1.2.4.3 As in8.2 of this specification Not applicable to styles referred to in note1 of this specification As in8.2 of this specification NOTESSeeend of table.BS9210N007-1:1976 8 BSI 04-

42、2000 Inspection BS9210:1971 reference and conditions of test Performance requirements Subgroup C5 (Contd) (D) Outer conductor continuity 1.2.4.4 As in8.2 of this specification Not applicable to styles referred to in note1 of this specification As in8.2 of this specification Voltage proof 1.2.4.7 As

43、in8.4 of this specification Not applicable to styles referred to in note1 of this specification As in8.4 of this specification Engagement and separation 1.2.5.5 To be achievable by hand in the normal manner Subgroup C6 CTR information 1.1.11 Attributes information for subgroups C3 and C5 GROUP D (D)

44、 D3 tests are to be performed at3 year intervals. In addition the issue number of the manufacturers drawing list shall be checked against that in the qualification approval application or certificate. Subgroups D1 and D2 are not applicable Specimens D3 (i):3 sets of piece parts for each style and va

45、riant Accept on one failure The minimum number of specimens (mating pairs) required for each of the remaining subgroups is: D3 (ii):15, subsequently used for D3 (iv) Accept on one failure Specimens D3 (iii):15, subsequently subdivided and used as follows: Accept on one failure D3 (vii):1 no failure

46、permitted D3 (viii):2 no failure permitted D3 (ix):5 Accept on one failure D3 (x):7 Accept on one failure D3 (v):15 Accept on one failure D3 (vi):15 Accept on one failure NOTESSeeend of table.BS9210N007-1:1976 BSI 04-2000 9 Inspection BS9210:1971 reference and conditions of test Performance requirem

47、ents GROUP D (Contd) Subgroup D3 (i) (Seenote1) Dimensions and materials (piece parts) 1.2.3.2 Three sets of piece parts for a connector in each style and variant. It is not necessary to repeat measurements on common piece parts from the same source of manufacture As in1.2.3.2 of BS9210 Subgroup D3

48、(ii) (Seenote1) Outline dimensions and mass 1.2.3.1 As in1.1, and Appendix A both of this specification Compatibility, mechanical (gauging) 1.2.5.9 1) Using compatibility gauges specified in control drawings BS9210 N007-2 As in1.2.5.9 1) of BS9210 Subgroup D3 (iii) (D) 8.5, 8.8 notes1 and2 apply to

49、tests in this subgroup. Connectors shall be assembled as for group B Contact and insert retention 1.2.5.3 Axial forces shall be applied initially from the rear end towards the mating face prior to fitting the cable or wire. The connector shall then be assembled as for group B. Matched styles shall be fitted with the appropriate cable from1.1, as selected for the purposes of test1.2.4.1, of this specification with free lengths of cable of250mm to300mm. Axial forces shall then be applied from the mating face towards the rear end . 1)22 1 N As

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf