BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf

上传人:testyield361 文档编号:548923 上传时间:2018-12-09 格式:PDF 页数:28 大小:293.23KB
下载 相关 举报
BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf_第1页
第1页 / 共28页
BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf_第2页
第2页 / 共28页
BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf_第3页
第3页 / 共28页
BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf_第4页
第4页 / 共28页
BS EN 1366-5-2010 Fire resistance tests for service installations - Service ducts and shafts《服务设施的防火试验 辅助通道和通风井》.pdf_第5页
第5页 / 共28页
亲,该文档总共28页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS EN1366-5:2010ICS 13.220.50; 91.060.40NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFire resistancetests for serviceinstallationsPart 5: Service ducts and shaftsThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommitte

2、e on 31 May2010. BSI 2010ISBN 978 0 580 52994 8Amendments/corrigenda issued since publicationDate CommentsBS EN 1366-5:2010National forewordThis British Standard is the UK implementation of EN 1366-5:2010. Itsupersedes BS EN 1366-5:2003 which is withdrawn.The UK participation in its preparation was

3、entrusted to TechnicalCommittee FSH/22/9, Fire resistance tests procedures and smokeextractions and dampers.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users a

4、re responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 1366-5:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1366-5 March 2010 ICS 13.220.50; 91.060.40 Supersedes EN 1366-5:2003English Version Fire resistance tests f

5、or service installations - Part 5: Service ducts and shafts Essais de rsistance au feu des installations de service - Partie 5: Gaines pour installation technique Feuerwiderstandsprfungen fr Installationen - Teil 5: Installationskanle und -schchte This European Standard was approved by CEN on 23 Jan

6、uary 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be ob

7、tained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Mana

8、gement Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Nether

9、lands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation i

10、n any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1366-5:2010: EBS EN 1366-5:2010EN 1366-5:2010 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Normative references 63 Terms and definitions .64 Test equipment 74.1 General 74.2 Furnace .74.3 Loading equipmen

11、t 74.4 Gas extraction equipment (optional) .75 Test conditions 75.1 Furnace .75.2 Loading .76 Test specimen 86.1 Size 86.1.1 General 86.1.2 Length .86.1.3 Cross-section .86.2 Number .86.3 Design .86.3.1 General 86.3.2 Duct and shaft arrangement .97 Installation of test specimen . 107.1 General . 107

12、.2 Standard supporting construction 107.3 Non-standard supporting constructions 108 Conditioning 118.1 General . 118.2 Sealing materials prepared with moisture . 119 Application of instrumentation 119.1 Thermocouples . 119.1.1 Furnace thermocouples (plate thermometers) 119.1.2 Thermocouple locations

13、 119.2 Pressure . 1210 Test procedure 1210.1 General . 1210.2 Test measurements and observations . 1210.2.1 General . 1210.2.2 Integrity 1210.2.3 Insulation (temperature of the surfaces outside the furnace for both exposure at the inside and exposure at the outside) . 1310.2.4 Additional observation

14、s . 1310.3 Termination of the test . 1311 Performance criteria . 1311.1 Integrity 1311.2 Insulation . 13BS EN 1366-5:2010EN 1366-5:2010 (E) 3 12 Test report 1313 Field of direct application of test results 1413.1 Walls or floors through which the ducts or shafts lead 1413.2 Sizes of ducts or shafts

15、1413.2.1 Fire exposure from outside 1413.2.2 Fire exposure from inside 1513.3 Admissible services 1513.4 Suspension devices for ducts . 1513.4.1 Material and sizing 1513.4.2 Elongation 1513.4.3 Dimensions in millimetres 16Bibliography 24BS EN 1366-5:2010EN 1366-5:2010 (E) 4 Foreword This document (E

16、N 1366-5:2010) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 20

17、10, and conflicting national standards shall be withdrawn at the latest by September 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rig

18、hts. This document supersedes EN 1366-5:2003. This document includes a bibliography. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Re

19、public, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 1366-5:2010EN 1366-5:2010 (E) 5 Introductio

20、n The purpose of this test is to measure the ability of a service duct or shaft to resist the spread of fire from one fire compartment to another with fire attack from inside or outside the duct or shaft. The test specimens incorporate joints and access openings as intended in practice and are suspe

21、nded as they would be in practice. Test specimens of service ducts are not loaded as in practice but a standard load is included to represent a typical service load. Test specimens of service shafts are not loaded as in practice, but a standard load is included to represent a typical service load. C

22、AUTION The attention of all persons concerned with managing and carrying out this fire resistance test is drawn to the fact that fire testing may be hazardous and that there is a possibility that toxic and/or harmful smoke and gases may be evolved during the test. Mechanical and operational hazards

23、may also arise during the construction of the test elements or structures, their testing and disposal of test residues. An assessment of all potential hazards and risks to health should be made and safety precautions should be identified and provided. Written safety instructions should be issued. Ap

24、propriate training should be given to relevant personnel. Laboratory personnel should ensure that they follow written safety instructions at all times. BS EN 1366-5:2010EN 1366-5:2010 (E) 6 1 Scope This European Standard specifies a method for determining the fire resistance of horizontal service du

25、cts and vertical service shafts, which pass through walls or floors and enclose pipes and cables. The test examines the behaviour of ducts and shafts exposed to fire from outside and from inside the duct. This European Standard is intended to be read in conjunction with EN 1363-1. This European Stan

26、dard does not examine the risk of fire spread as a result of thermal conduction along the piping installed in service ducts or shafts, or thermal conduction through the media these pipes carry. It does not cover the risk of damage produced by thermal elongation or shortening of tubes and cables as a

27、 result of fire, or damaged pipe suspensions. This European Standard does not give guidance on how to test one, two or three sided service ducts or shafts. NOTE Guidance on testing service ducts and shafts of less than four sides will be covered in the extended field of application rules being devel

28、oped by CEN/TC 127. This test is unsuitable for evaluating service ducts with internal barriers at walls and floors. Whilst the walls of service ducts or shafts tested to this method may provide specified levels of integrity or insulation, testing to this European Standard does not replace the testi

29、ng of the functional endurance of small electrical cables which is covered in EN 50200. Fire resistance testing of ducts for air distribution systems is covered in EN 1366-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated r

30、eferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:1999, Fire resistance tests Part 1: General requirements EN 1366-3, Fire resistance tests for service installations Part 3: Penetration seals

31、 EN ISO 898-1:2009, Mechanical properties of fasteners made of carbon steel and alloy steel Part 1: Bolts, screws and studs with specified property classes Coarse thread and fine pitch thread (ISO 898-1:2009) EN ISO 13943:2000, Fire safety Vocabulary (ISO 13943:2000) 3 Terms and definitions For the

32、purposes of this document, the terms and definitions given in EN 1363-1:1999, EN ISO 13943:2000 and the following apply. 3.1 service duct horizontal duct enclosing combustible or non-combustible services, such as pipes or cables 3.2 service shaft vertical shaft enclosing combustible or non-combustib

33、le services, such as pipes or cables BS EN 1366-5:2010EN 1366-5:2010 (E) 7 3.3 shutter of access opening openable door or panel allowing for access to the services within the duct or shaft 3.4 supporting construction wall, partition or floor which the duct passes through in the test 4 Test equipment

34、 4.1 General In addition to the test equipment specified in EN 1363-1, the following are required. 4.2 Furnace The furnace shall be capable of subjecting service ducts and shafts to the standard heating and pressure conditions specified in EN 1363-1 and be suitable for testing horizontal ducts (see

35、Figures 1 and 2) or vertical shafts (see Figures 3 and 4). 4.3 Loading equipment Stranded steel cables are used to apply load to the bottom internal face of the service duct to represent service loading, or any other equivalent equipment. 4.4 Gas extraction equipment (optional) If for safety reasons

36、 a laboratory requires to extract gases away from the open end of the duct or shaft, this shall not influence the test conditions. 5 Test conditions 5.1 Furnace The heating and pressure conditions and the furnace atmosphere shall conform to those given in EN 1363-1. 5.2 Loading Horizontal service du

37、cts shall be loaded when supporting service installations. In this case, the load shall be representative of that used in practice. Vertical service shafts shall not be loaded except in the two following situations: when supporting service installations. In this case, the load shall be representativ

38、e of that used in practice; when the service installation shaft is not fixed to each floor or when the height between two supports is greater than 5 m. In this case a weight load shall be added to the shaft length of the next floor. BS EN 1366-5:2010EN 1366-5:2010 (E) 8 6 Test specimen 6.1 Size 6.1.

39、1 General Any size of duct or shaft may be tested as required by the sponsor. However, sizes other than those in Tables 1 and 2 may have restricted direct field of application. 6.1.2 Length The minimum lengths of the parts of the test specimen inside and outside the furnace shall be as given in Tabl

40、e 1. Table 1 Minimum length of test specimen Orientation Minimum length m Inside furnace Outside furnace fire outside fire inside fire outside fire inside Horizontal duct 4,0 0,25 2,0 2,5 Vertical shaft a2,0 0,25 2,0 2,0aSee also 5.2. 6.1.3 Cross-section The standard sizes of duct and shaft shall be

41、 as given in Table 2. Table 2 Cross-section of test specimen Exposure conditions Width mm Height mm Fire inside 1 000 10 500 10 Fire outside size (1) 200 10 a200 10 asize (2) 1 000 10 500 10 aOr the smallest size intended in practice. 6.2 Number One test specimen shall be tested for each type of ori

42、entation, exposure conditions and cross-section (see Table 2). 6.3 Design 6.3.1 General The test shall be made on a test specimen, representative of the complete service duct assembly, on which information is required. BS EN 1366-5:2010EN 1366-5:2010 (E) 9 6.3.2 Duct and shaft arrangement 6.3.2.1 Ge

43、neral Ducts shall be arranged as shown in Figures 1 and 2 and shafts shall be arranged as shown in Figures 3 and 4. Service ducts or shafts with fire exposure from outside will have no openings in the furnace (except access panels). For service ducts or shafts exposed to an internal fire, the end of

44、 the duct facing into the furnace shall be left open. No ducts or shafts shall contain anything other than the standard cables for loading. The exposure condition (fire inside or fire outside) shall be as specified by the sponsor. Where used in practice, each service duct or shaft shall incorporate

45、one access opening as follows: fire outside: inside furnace at mid-span of exposed section of duct; fire inside: as shown in Figure 2 (the dimensions may be applied also to vertical shafts). For the test, the access opening shall be at the bottom of the duct. The size of the access opening shall be

46、representative of practice. Vertical shafts shall be arranged as shown in Figures 3 and 4 and shall penetrate through the furnace roof slab/supporting construction. The shafts shall be fixed at the furnace roof level as they would be fixed in practice when penetrating a floor (as specified by the sp

47、onsor). 6.3.2.2 Joints in horizontal ducts The test configuration shall include at least one joint inside the furnace and at least one joint outside it. There shall be at least one joint for every layer of fire protection material, both inside and outside the furnace and in any steel duct. Outside t

48、he furnace, the joint in the outer layer of the fire protection material shall be no further than 700 mm from the supporting construction and no nearer than 100 mm to thermocouples T2 in accordance with 9.1. Inside the furnace, the joint in the outer layer of fire protection material shall be locate

49、d at approximately mid-span. The location of joints in inner layers shall be as specified by the sponsor. The distance between joints and suspension devices shall not be less than that used in practice. If the minimum distance has not been specified, suspension devices shall be arranged so that the joint at mid-span lies

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1