BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf

上传人:ownview251 文档编号:549179 上传时间:2018-12-09 格式:PDF 页数:36 大小:1.40MB
下载 相关 举报
BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf_第1页
第1页 / 共36页
BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf_第2页
第2页 / 共36页
BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf_第3页
第3页 / 共36页
BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf_第4页
第4页 / 共36页
BS EN 1627-2011 Pedestrian doorsets windows curtain walling grilles and shutters Burglar resistance Requirements and classification《人行门具 窗 幕墙 栅格和百叶窗 防盗 要求和分类》.pdf_第5页
第5页 / 共36页
亲,该文档总共36页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS EN 1627:2011Incorporating corrigendum June 2013raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1627:2011Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Requirements and classific

2、ationBS EN 1627:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1627:2011. It supersedes DD ENV 1627:1999, which is withdrawn.BSI, as a member of CEN, is obliged publish EN 1627 as a British Standard. However, attention is drawn to the fact that during the

3、development of this European Standard, the UK committee voted against its approval as a European Standard.The reason for this vote by the UK committee B/538, is due to concerns regarding to the scope of this standard does not address all known burglary methods or account for specific attacks upon lo

4、ck products. This standard does not provide a means of testing windows and doorsets with an intended use for Resistance classes 2 and 3 as specified in Table C.1 of this standard. However they can be tested and assessed in accordance with BS 6375-3:2009 clause 5.13.2 in conjunction with the UK Polic

5、e Service (Secured by Design) Interpretation document for BS EN 1627, BS EN 1628, BS EN 1629 91.060.50Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 201

6、1.Amendments/corrigenda issued since publicationDate Text affected30 June 2013 National Foreword revisedBS EN 1627:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1627 May 2011 ICS 13.310; 91.060.50 Supersedes ENV 1627:1999English Version Pedestrian doorsets, windows, curtain walling, grill

7、es and shutters - Burglar resistance - Requirements and classificationBlocs-portes pour pitons, fentres, faades rideaux, grilles et fermetures - Rsistance leffraction - Prescriptions et classification Tren, Fenster, Vorhangfassaden, Gitterelemente und Abschlsse - Einbruchhemmung - Anforderungen und

8、Klassifizierung This European Standard was approved by CEN on 2 December 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bib

9、liographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respo

10、nsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Gr

11、eece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Manage

12、ment Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1627:2011: EBS EN 1627:2011 EN 1627:2011 (E) 2 Contents Page Foreword . . 31 Scope. 42 Normative references . . 43 Terms and defini

13、tions . . 54 Resistance classification . . 65 Infillings . . 76 Hardware . 77 Mechanical strength . . 87.1 Static loading . . 87.2 Dynamic loading in resistance classes 1, 2 and 3 . . 118 Manual burglary attempts . 119 Classification report . . 1110 Installation . . 1211 Test specimens . . 12Annex A

14、 (informative) Recommendations for the contents of the manufacturers installation instructions. 13Annex B (normative) Requirements for locks and hardware outside the scope of the standards listed in Table 2 . . 14Annex C (informative) Resistance classes Classification according to EN 1627 . 23C.1 In

15、troduction . . 23C.2 Resistance classes 1 to 3 . . 23C.3 Resistance classes 4 to 6 . . 23Annex D (normative) Field of application . 25D.1 Dimensions . 25D.2 Exchange of hardware elements 27D.3 Other modifications . 28Annex E (normative) Procedure for testing and classification 29Bibliography . . 31B

16、S EN 1627:2011EN 1627:2011 (E) 3 Foreword This document (EN 1627:2011) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national stand

17、ard, either by publication of an identical text or by endorsement, at the latest by November 2011, and conflicting national standards shall be withdrawn at the latest by November 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent right

18、s. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes ENV 1627:1999. This European Standard is one of a series of standards for burglar resistant pedestrian doorsets, windows, curtain walling, grilles and shutters. The other stand

19、ards in the series are: EN 1628:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance under static loading; EN 1629:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test

20、 method for the determination of resistance under dynamic loading; EN 1630:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance to manual burglary attempts. This standard is a revision of, and supersedes ENV 1627

21、:1999. The three other standards in this series are revisions of, and supersede ENV 1628, ENV 1629 and ENV 1630 respectively. This revision incorporates grilles and curtain walling in the range of application. According to the CEN/CENELEC Internal Regulations, the national standards organizations of

22、 the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma

23、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 1627:2011EN 1627:2011 (E) 4 1 Scope This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters.

24、 It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies re

25、quirements for the burglar resistance of a construction product (as defined in 3.1 of this standard). This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover precast concrete elements. It also does not cover the attack

26、 of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics. NOTE 1 The mechanical parts of electric, electronic and electromagnetic operated burglar resistant construction products may be tested in electr

27、ical powerless condition. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or r

28、esidential premises, as covered by EN 13241-1. NOTE 2 Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc. 2 Normative references The following referenced documents are indispensable for the appli

29、cation of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 356:1999, Glass in building Security glazing Testing and classification of resistance against manual attack EN 1

30、303:2005, Building hardware Cylinders for locks Requirements and test methods EN 1628:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance under static loading EN 1629:2011, Pedestrian doorsets, windows, curtain

31、walling, grilles and shutters Burglar resistance Test method for the determination of resistance under dynamic loading EN 1630:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance to manual burglary attempts EN 1

32、906:2010, Building hardware Lever handles and knob furniture Requirements and test methods EN 12209:2003, Building hardware Locks and latches Mechanically operated locks, latches and locking plates Requirements and test methods EN 12519:2004, Windows and pedestrian doors Terminology ISO 1000:1992, S

33、I units and recommendations for the use of their multiples and of certain other units BS EN 1627:2011EN 1627:2011 (E) 5 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12519:2004 and in ISO 1000:1992 and the following apply. 3.1 burglar resistance pro

34、perty of pedestrian doorsets, windows, curtain walling, grilles and shutters to resist attempts at forced entry using physical force and with the aid of predefined tools into the protected room or area 3.2 burglar resistant product complete, functioning element that, when built in and fastened or fa

35、stened and locked, has the function of resisting forced entry through the application of physical force assisted by predefined tools 3.3 Group 1 product product that has a solid and rigid leaf or opening element and the principal movement to open is turning of the element NOTE Examples of Group 1 pr

36、oducts are hinged or pivoted windows and doorsets. 3.4 Group 2 product product that has a solid and rigid leaf or opening element and the principal movement to open is sliding NOTE Examples of Group 2 products are sliding doorsets and sliding windows. 3.5 Group 3 product product that has a leaf or o

37、pening element constructed from a number of rigid elements joined together such that the elements may move relative to each other NOTE An example of a Group 3 product is a roller shutter. 3.6 Group 4 product product with one or more openings (excluding letter plates) through which gap gauge B (25 mm

38、) can pass NOTE An example of a Group 4 product is a grille. 3.7 resistance class (RC) level of resistance that the product provides against burglary attempts 3.8 attack side side of the test specimen defined by the applicant as the side exposed to attack 3.9 non-attack side side of the test specime

39、n defined by the applicant as the side not exposed to attack 3.10 roller shutter shutter, the curtain of which consists of movable, interconnected rigid elements, and travels over a roller in order to open/close BS EN 1627:2011EN 1627:2011 (E) 6 3.11 roller grille component that can be moved vertica

40、lly or horizontally in front of the opening to be secured and that can also be removed NOTE The individual grille bars are movably interconnected with each other. The grille curtain travels over a roller in order to open. 3.12 closed condition condition defined and described by the manufacturer or a

41、pplicant in which the tested element meets the burglar resistant requirements 3.13 closed and fastened condition condition where the window, doorset or shutter is secured in such a way that it can be opened from the non-attack side without a key, but that it cannot be opened from the attack side wit

42、hout a key 3.14 closed, fastened and locked condition condition where the window, doorset or shutter is secured in such a way that it cannot be opened from either side without a key 3.15 resistance time working time of the test person carrying out the manual burglary test NOTE The resistance time in

43、cludes times of less than 5 s each for tool changes, e.g. exchanging a screwdriver for a crow bar. 3.16 infilling glazing or panel of any material or combination of materials which are used to fill an aperture in a window or doorset that can be replaced, and which are typically retained by glazing b

44、eads 4 Resistance classification Each construction product conforming to this standard shall be classified according to one of six resistance classes, depending on the level of burglar resistance offered by the product. NOTE The resistance classes correspond to known methods of attack currently used

45、 by burglars as described in Annex C, Table C.1. A system or family of products shall be classified using the approach described in Annex D. A product offering burglar resistance at more than one closing condition shall be tested, assessed and classified at each closing condition. In the documentati

46、on accompanying the product, the resistance class shall be given as per the following examples: Burglar resistant window EN 1627 RC 1N Burglar resistant window EN 1627 RC 3 Burglar resistant door EN 1627 RC 2. The procedure for testing and classification shall be carried out as described in Annex F.

47、 BS EN 1627:2011EN 1627:2011 (E) 7 For the purpose of historic data, products classified under ENV 1627:1999 to classes 2 to 6 can be assumed to meet the same classes of this standard. 5 Infillings When tested in accordance with EN 1628:2011, EN 1629:2011 or EN 1630:2011, infilling other than glass

48、shall not exhibit failure at the resistance class claimed. This standard specifies requirements relating to the security level of glazing. When several panes of glass are used in a product, e.g. insulating glass units, then at least one pane shall meet the resistance class as shown in Table 1. Table

49、 1 Minimum requirements for glazings Resistance class Resistance class of glazing according to EN 356RC 1 N No requirements* RC 2 N No requirements* RC 2 P4 A RC 3 P5 A RC 4 P6 B RC 5 P7 B RC 6 P8 B * In these resistance classes, national provisions may be followed. NOTE The use of furniture that requires a removable key to effect unlocking might be required when glazing with a resistance class lower than P4A is used. 6 Hardware Lock cylinders, furniture and

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1