1、BRITISH STANDARDBS EN 2349-301:2006Aerospace series Requirements and test procedures for relays and contactors Part 301: Pick-up and drop-out voltageThe European Standard EN 2349-301:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g
2、51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 2349-301:2006This British Standard was published under the authority
3、of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50017 6National forewordThis British Standard was published by BSI. It is the UK implementation of EN 2349-301:2006.The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace a
4、vionic electrical and fibre optic technology, to Panel ACE/6/-/4, Aerospace Switching devices.A list of organizations represented on ACE/6/-/4 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible fo
5、r its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE N
6、ORMEN 2349-301October 2006ICS 49.060English VersionAerospace series - Requirements and test procedures for relaysand contactors - Part 301: Pick-up and drop-out voltageSrie arospatiale - Exigences et mthodes dessais desrelais et contacteurs - Partie 301 : Tension de collage et dedcollageLuft- und Ra
7、umfahrt - Anforderungen und Prfverfahren frRelais und Schaltschtze - Teil 301: Ansprechspannungund RckfallspannungThis European Standard was approved by CEN on 10 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europea
8、nStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, Fren
9、ch, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic
10、, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALI
11、SATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2349-301:2006: ELicensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontro
12、lled Copy, (c) BSI2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Pick-up (actuating) voltage.4 4 Drop-out (release) voltage 4 EN 2349-301:2006Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSI3 Foreword This document (EN 2349-301:2006) has bee
13、n prepared by the AeroSpace and Defense Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member
14、countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2007, and conflicting national standards shall be withdrawn at the latest by April 2007. A
15、ttention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations
16、 of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, S
17、lovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 2349-301:2006Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSI4 1 Scope This standard specifies a method for testing the pick-up voltage and drop-out voltage of relays and contactors. It shall be
18、 used together with EN 2349-100. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) ap
19、plies. EN 2349-100, Aerospace series Requirements and test procedures for relays and contactors Part 100: General requirements 1)3 Pick-up (actuating) voltage 3.1 Mounting method The relay or contactor shall be wired in accordance with EN 2349-100. 3.2 Test procedure The coil shall be left in a de-e
20、nergized state for 30 min before starting the test. The minimum rate of voltage increase and the time to energize the coil, applicable to the device under test, shall be determined to prevent overheating of the coil. The rated voltage shall be applied to the coil, then reduced to zero, and gradually
21、 increased until the relay or contactor picks up. The contacts shall not change their switching position when the voltage is increased from the pick-up voltage to the maximum operating voltage. An indicating device shall be used to determine the position of the contacts. For qualification tests, the
22、 relay or contactor shall be tested in each of two directions along three axes which are perpendicular to each other (i.e. six degrees of freedom). 3.3 Test criteria The relay or contactor shall pick up at the rated voltage specified in the product standard. 4 Drop-out (release) voltage 4.1 Mounting
23、 method The relay or contactor shall be wired as described in EN 2349-100. 1) In preparation at the date of publication of this standard. EN 2349-301:2006Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSI5 4.2 Test procedure The coil shall be left in a de-ene
24、rgized condition for 30 min before starting the test. The rated voltage shall be applied to the coil and then gradually reduced until the relay or contactor drops out. The contacts shall not change their switching position when the voltage is reduced from the drop-out voltage to zero. An indicating
25、device shall be used to determine the position of the contacts. For qualification tests the switching device shall be tested in each of the three axes which are perpendicular to each other. 4.3 Test criteria The relay or contactor shall drop-out within the voltage range specified in the product stan
26、dard. EN 2349-301:2006Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 2349-301:2006BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British Standards. It presents the
27、UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve
28、 the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fa
29、x: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Te
30、l: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-.In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless
31、 otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its produc
32、ts and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefit
33、s contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding online access to British Standards via British Standards Online can be found at http:/www.bsi- information about BSI is available on the BSI website at http:/www.bsi-.
34、CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitt
35、ed in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI.This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are
36、to be used for any other purpose than implementation then the prior written permission of BSI must be obtained.Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: copyrightbsi-.Licensed Copy: Wang Bin, na, Wed Apr 04 07:59:49 GMT+00:00 2007, Uncontrolled Copy, (c) BSI