1、BRITISH STANDARD AEROSPACE SERIES BS EN 2591-317:1998 Elements of electrical and optical connection Test methods Part 317: Flammability The European Standard EN2591-317:1998 has the status of a British Standard ICS 49.060BSEN2591-317:1998 This British Standard, having been prepared under the directi
2、onof the Engineering SectorBoard, was published underthe authority of the Standards Board and comes intoeffect on 15 August1998 BSI 05-1999 ISBN 0 580 30305 5 National foreword This British Standard is the English language version of EN2591-317:1998. The UK participation in its preparation was entru
3、sted by Technical Committee ACE/6, Aerospace avionic, electrical and fibre optic technology, to Subcommittee ACE/6/3, Aerospace-Connectors, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpre
4、tation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which
5、implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not
6、purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside fro
7、nt cover, pages i and ii, the EN title page, pages 2 to 4 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date Comment
8、sBSEN2591-317:1998 BSI 05-1999 i Contents Page National foreword Inside front cover Foreword 2 Text of EN 2591-317 3ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 2591-317 June 1998 ICS 49.060 Descriptors: Aircraft industry, aircraft equipment, connecting equipment, test English versio
9、n Aerospace series Elements of electrical and optical connection Test methods Part 317: Flammability Srie arospatiale Organes de connexion lectrique et optique Mthodes dessais Partie 317: Ininflammabilit Luft- und Raumfahrt Elektrische und optische Verbindungselemente Prfverfahren Teil 317: Nichtent
10、flammbarkeit This European Standard was approved by CEN on22 June1997. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliograph
11、ical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN
12、 member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, CzechRepublic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, P
13、ortugal, Spain, Sweden, Switzerland and United Kingdom. CEN European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels 1998 CEN All rights of exploitation in any form and by any means reserved worldwid
14、e for CEN national Members. Ref. No. EN 2591-317:1998 EEN2591-317:1998 BSI 05-1999 2 Foreword This European Standard has been prepared by the European Association of Aerospace Manufacturers (AECMA). After inquiries and votes carried out in accordance with the rules of this Association, this Standard
15、 has received the approval of the National Associations and the Official Services of the member countries of AECMA, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest b
16、y December1998, and conflicting national standards shall be withdrawn at the latest by December1998. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, CzechRepublic, Denm
17、ark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Preparation of specimens 3 4 Apparatus 3 5 Method 4 Figure 1 4EN2591-317:1998 BS
18、I 05-1999 3 1 Scope This standard specifies a method of verifying the flammability of elements of connection. It shall be used together with EN2591. 2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative references
19、 are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the lates
20、t edition of the publication referred to applies. ISO 4046-1978, Paper, board, pulp and related terms Vocabulary. EN 2591, Aerospace series Elements of electrical and optical connection Test methods General. EN 2591-101, Aerospace series Elements of electrical and optical connection Test methods Par
21、t 101: Visual examination. EN 2591-207, Aerospace series Elements of electrical and optical connection Test methods Part 207: Voltage proof test. EN 2591-312, Aerospace series Elements of electrical and optical connection Test methods Part 312: Air leakage 1) . EN 2591-409, Aerospace series Elements
22、 of electrical and optical connection Test methods Part 409: Contact retention in insert 1) . 3 Preparation of specimens 3.1 Specimens shall be prepared according to the technical specification. Unwired cavities shall be fitted with filler plugs. 3.2 Unless specified in the technical specification,
23、the following details shall be stated: specimens mated or unmated and fitted with protective covers; mounting method, type of cable (non propagating flames) and definition of specimen wiring; method A or B; final measurements and requirements (ifapplicable); force to be applied according to EN2591-4
24、09; leakage rate according to EN2591-312; method according to EN2591-207 and voltage value. 4 Apparatus The dimensions of the chamber shall be approximately as follows: length 300mm, width300mm, height 600mm (seeFigure 1). It shall be open on the top and front faces. The air circulation shall be suf
25、ficient but there shall be no draught. The specimens shall be held in position with a suitable device so that the thermal inertia is negligible. The specimens shall be installed in the test chamber with their longitudinal axis positioned at an angle of(30 5) to the horizontal. For specimens with pro
26、tective covers, cables shall be directed downwards. A piece of easily flammable paper (tissue paper to ISO4046) approximately250mm 250mm shall be stretched over a frame, about300mm to350mm below the specimens. The burner with a nozzle diameter of approximately10mm shall be positioned under the speci
27、men so that its axis is at an angle of30 to the vertical. The flame shall be50mm to70mm high and its hottest point on the edge of the specimens shall have a temperature of (955 30) C. 1) Published as AECMA Prestandard at the date of publication of this standardEN2591-317:1998 4 BSI 05-1999 5 Method
28、5.1 Test procedure The flame shall be applied for (30 1) s to the lower edge of the specimens. It shall also cover any possible non-metallic materials of accessories. Method A safety:5.2.1 applies Method B safety and functioning:5.2.1 and5.2.2 apply. 5.2 Requirements 5.2.1 Throughout the test there
29、shall be no dripping which shall cause paper to ignite. Burning and afterglow shall extinguish within 30 s from removal of the flame. 5.2.2 Final measurements and requirements (if applicable) The specimens shall be subjected to the following test sequence: EN 2591-207: at ambient temperature with250
30、 V r.m.s., 40 Hz to60 Hz; EN 2591-101: damage to the insert exposing the contact by3mm or more is not acceptable; EN 2591-409: with50% of the nominal load applied for5 s; EN 2591-312: only for hermetic elements of connection. Figure 1 blankBS EN 2591-317:1998 BSI 389 Chiswick High Road London W4 4AL
31、 BSIBritishStandardsInstitution BSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions BritishStandards are updated by amendment or revision. Users
32、of BritishStandards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this BritishStandard would inform the Secretary o
33、f the technical committee responsible, the identity of which can be found on the inside front cover. Tel:02089969000. Fax:02089967400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards
34、 Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel:02089969001. Fax:02089967001. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as BritishStandards
35、, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all
36、its products and services. Contact the Information Centre. Tel:02089967111. Fax:02089967048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Adm
37、inistration. Tel:02089967002. Fax:02089967001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the internationalstandardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reprod
38、uced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, t
39、ype or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel:02089967070.